Refine
Year of publication
Document Type
- Article (120)
- Postprint (38)
- Conference Proceeding (33)
- Other (14)
- Preprint (3)
- Review (2)
- Part of Periodical (1)
Keywords
- sonography (15)
- EMG (10)
- MiSpEx (8)
- young athletes (8)
- reliability (7)
- Exercise (6)
- Basketball (5)
- Children (5)
- Functional ankle instability (5)
- Perturbation (5)
Institute
- Department Sport- und Gesundheitswissenschaften (139)
- Strukturbereich Kognitionswissenschaften (19)
- Humanwissenschaftliche Fakultät (17)
- Hochschulambulanz (12)
- Institut für Ernährungswissenschaft (10)
- Fakultät für Gesundheitswissenschaften (6)
- Extern (4)
- Department Linguistik (2)
- Institut für Biochemie und Biologie (2)
- Institut für Physik und Astronomie (2)
Low back pain (LBP) is a leading cause of activity limitation. Objective assessment of the spinal motion plays a key role in diagnosis and treatment of LBP. We propose a method that facilitates clinical assessment of lower back motions by means of a wireless inertial sensor network. The sensor units are attached to the right and left side of the lumbar region, the pelvis and the thighs, respectively. Since magnetometers are known to be unreliable in indoor environments, we use only 3D accelerometer and 3D gyroscope readings. Compensation of integration drift in the horizontal plane is achieved by estimating the gyroscope biases from automatically detected initial rest phases. For the estimation of sensor orientations, both a smoothing algorithm and a filtering algorithm are presented. From these orientations, we determine three-dimensional joint angles between the thighs and the pelvis and between the pelvis and the lumbar region. We compare the orientations and joint angles to measurements of an optical motion tracking system that tracks each skin-mounted sensor by means of reflective markers. Eight subjects perform a neutral initial pose, then flexion/extension, lateral flexion, and rotation of the trunk. The root mean square deviation between inertial and optical angles is about one degree for angles in the frontal and sagittal plane and about two degrees for angles in the transverse plane (both values averaged over all trials). We choose five features that characterize the initial pose and the three motions. Interindividual differences of all features are found to be clearly larger than the observed measurement deviations. These results indicate that the proposed inertial sensor-based method is a promising tool for lower back motion assessment.
Accuracy of training recommendations based on a treadmill multistage incremental exercise test
(2018)
Competitive runners will occasionally undergo exercise in a laboratory setting to obtain predictive and prescriptive information regarding their performance. The present research aimed to assess whether the physiological demands of lab-based treadmill running (TM) can simulate that of over-ground (OG) running using a commonly used protocol. Fifteen healthy volunteers with a weekly mileage of ≥ 20 km over the past 6 months and treadmill experience participated in this cross-sectional study. Two stepwise incremental tests until volitional exhaustion was performed in a fixed order within one week in an Outpatient Clinic research laboratory and outdoor athletic track. Running velocity (IATspeed), heart rate (IATHR) and lactate concentration at the individual anaerobic threshold (IATbLa) were primary endpoints. Additionally, distance covered (DIST), maximal heart rate (HRmax), maximal blood lactate concentration (bLamax) and rate of perceived exertion (RPE) at IATspeed were analyzed. IATspeed, DIST and HRmax were not statistically significantly different between conditions, whereas bLamax and RPE at IATspeed showed statistical significance (p < 0.05). Apart from RPE at IATspeed, IATspeed, DIST, HRmax and bLamax strongly correlate between conditions (r = 0.815–0.988). High reliability between conditions provides strong evidence to suggest that running on a treadmill are physiologically comparable to that of OG and that training recommendations and be made with assurance.
Accuracy of training recommendations based on a treadmill multistage incremental exercise test
(2018)
Competitive runners will occasionally undergo exercise in a laboratory setting to obtain predictive and prescriptive information regarding their performance. The present research aimed to assess whether the physiological demands of lab-based treadmill running (TM) can simulate that of over-ground (OG) running using a commonly used protocol. Fifteen healthy volunteers with a weekly mileage of ≥ 20 km over the past 6 months and treadmill experience participated in this cross-sectional study. Two stepwise incremental tests until volitional exhaustion was performed in a fixed order within one week in an Outpatient Clinic research laboratory and outdoor athletic track. Running velocity (IATspeed), heart rate (IATHR) and lactate concentration at the individual anaerobic threshold (IATbLa) were primary endpoints. Additionally, distance covered (DIST), maximal heart rate (HRmax), maximal blood lactate concentration (bLamax) and rate of perceived exertion (RPE) at IATspeed were analyzed. IATspeed, DIST and HRmax were not statistically significantly different between conditions, whereas bLamax and RPE at IATspeed showed statistical significance (p < 0.05). Apart from RPE at IATspeed, IATspeed, DIST, HRmax and bLamax strongly correlate between conditions (r = 0.815–0.988). High reliability between conditions provides strong evidence to suggest that running on a treadmill are physiologically comparable to that of OG and that training recommendations and be made with assurance.
Objectives: Although expected, tendon adaptations in adolescent elite athletes have been underreported. Morphologically, adaptations may occur by an increase in collagen fiber density and/or organization. These characteristics can be captured using spatial frequency parameters extracted from ultrasound images. This study aims to compare Achilles tendon (AT) morphology among sports-specific cohorts of elite adolescent athletes and to compare these findings to recreationally active controls by use of spatial frequency analysis. Design: Cross-sectional observational study. Method: In total, 334 healthy adolescent athletes from four sport categories (ball, combat, endurance, explosive strength) and 35 healthy controls were included. Longitudinal ultrasound scans were performed at the AT insertion and midportion. Intra-tendinous-morphology was quantified by performing spatial frequency analysis assessing eight parameters at standardized ROls. Increased values in five parameters suggest a higher structural organization, and in two parameters higher fiber density. One parameter represents a quotient combining both organization and fiber density. Results: Among athletes, only ball sport athletes exhibited an increase in one summative parameter at pre-insertion site compared to athletes from other sport categories. When compared to athletes, controls had significantly higher values of four parameters at pre-insertion and three parameters at midportion site reflecting differences in both, fiber organization and density. Conclusions: Intra-tendinous-morphology was similar in all groups of adolescent athletes. Higher values found in non-athletes might suggest higher AT fiber density and organization. It is yet unclear whether the lesser structural organization in young athletes represents initial AT pathology, or a physiological adaptive response at the fiber cross-linking level. (C) 2019 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Chronic ankle instability (CAI) is not only an ankle issue, but also affects sensorimotor system. People with CAI show altered muscle activation in proximal joints such as hip and knee. However, evidence is limited as controversial results have been presented regarding changes in activation of hip muscles in CAI population. PURPOSE: To investigate the effect of CAI on activity of hip muscles during normal walking and walking with perturbations. METHODS: 8 subjects with CAI (23 ± 2 years, 171 ± 7 cm and 65 ± 4 kg) and 8 controls (CON) matched by age, height, weight and dominant leg (25 ± 3 years, 172 ± 7 cm and 65 ± 6 kg) walked shoed on a split-belt treadmill (1 m/s). Subjects performed 5 minutes of baseline walking and 6 minutes walking with 10 perturbations (at 200 ms after heel contact with 42 m/s2 deceleration impulse) on each side. Electromyography signals from gluteus medius (Gmed) and gluteus maximus (Gmax) were recorded while walking. Muscle amplitudes (Root Mean Square normalized to maximum voluntary isometric contraction) were calculated at 200 ms before heel contact (Pre200), 100 ms after heel contact (Post100) during normal walking and 200 ms after perturbations (Pert200). Differences between groups were examined using Mann Whitney U test and Bonferroni correction to account for multiple testing (adjust α level p≤ 0.0125). RESULT: In Gmed, CAI group showed lower muscle amplitude than CON group after heel contact (Post100: 18±7 % and 47±21 %, p< .01) and after walking perturbations ( 31±13 % and 62±26 %, p< .01), but not before heel contact (Pre200: 5±2 % and 11±10 %, p= 0.195). In Gmax, no difference was found between CAI and CON groups in all three time points (Pre200: 12±5 % and 17±12 %, p= 0.574; Post100: 41±21 % and 41±13 %, p= 1.00; Pert200: 79±46 % and 62±35 %, p= 0.505). CONCLUSION: People with CAI activated Gmed less than healthy control in feedback mechanism (after heel contact and walking with perturbations), but not in feedforward mechanism (before heel contact). Less activation on Gmed may affect the balance in frontal plane and increase the risk of recurrent ankle sprain, giving way or feeling ankle instability in patients with CAI during walking. Future studies should investigate the effect of Gmed strengthening or neuromuscular training on CAI rehabilitation.
Sonographically detectable intratendinous blood flow (IBF) is found in 50%-88% of Achilles tendinopathy patients as well as in up to 35% of asymptomatic Achilles tendons (AT). Although IBF is frequently associated with tendon pathology, it may also represent a physiological regulation, for example, due to increased blood flow in response to exercise. Therefore, this study aimed to investigate the acute effects of a standardized running exercise protocol on IBF assessed with Doppler ultrasound (DU) Advanced dynamic flow in healthy ATs. 10 recreationally active adults (5 f, 5m; 29 +/- 3years, 1.72 +/- 0.12m, 68 +/- 16kg, physical activity 206 +/- 145minute/wk) with no history of AT pain and inconspicious tendon structure performed 3 treadmill running tasks on separate days (M1-3) with DU examinations directly before and 5, 30, 60, and 120minutes after exercise. At M1, an incremental exercise test was used to determine the individual anaerobic threshold (IAT). At M2 and M3, participants performed 30-minute submaximal constant load tests (CL1/CL2) with an intensity 5% below IAT. IBF in each tendon was quantified by counting the number of vessels. IBF increased in five ATs from no vessels at baseline to one to four vessels solely detectable 5minutes after CL1 or CL2. One AT had persisting IBF (three vessels) throughout all examinations. Fourteen ATs revealed no IBF at all. Prolonged running led to a physiological, temporary appearance of IBF in 25% of asymptomatic ATs. To avoid exercise-induced IBF in clinical practice, DU examinations should be performed after 30minutes of rest.
Repetitive overhead motions in combination with heavy loading were identified as risk factors for the development of shoulder pain. However, the underlying mechanism is not fully understood. Altered scapular kinematics as a result of muscle fatigue is suspected to be a contributor. PURPOSE: To determine scapular kinematics and scapular muscle activity at the beginning and end of constant shoulder flexion and extension loading in asymptomatic individuals. METHODS: Eleven asymptomatic adults (28±4yrs; 1.74±0.13m; 74±16kg) underwent maximum isokinetic loading of shoulder flexion (FLX) and extension (EXT) in the sagittal plane (ROM: 20- 180°; concentric mode; 180°/s) until individual peak torque was reduced by 50%. Simultaneously 3D scapular kinematics were assessed with a motion capture system and scapular muscle activity with a 3-lead sEMG of upper and lower trapezius (UT, LT) and serratus anterior (SA). Scapular position angles were calculated for every 20° increment between 20-120° humerothoracic positions. Muscle activity was quantified by amplitudes (RMS) of the total ROM. Descriptive analyses (mean±SD) of kinematics and muscle activity at begin (taskB) and end (taskE) of the loading task was followed by ANOVA and paired t-tests. RESULTS: At taskB activity ranged from 589±343mV to 605±250mV during FLX and from 105±41mV to 164±73mV during EXT across muscles. At taskE activity ranged from 594±304mV to 875±276mV during FLX and from 97±33mV to 147±57mV during EXT. Differences with increased muscle activity were seen for LT and UT during FLX (meandiff= 141±113mV for LT, p<0.01; 191±153mV for UT, p<0.01). Scapula position angles continuously increased in upward rotation, posterior tilt and external rotation during FLX and reversed during EXT both at taskB and taskE. At taskE scapula showed greater external rotation (meandiff= 3.6±3.7°, p<0.05) during FLX and decreased upward rotation (meandiff= 1.9±2.3°, p<0.05) and posterior tilt (meandiff= 1.0±2.1°, p<0.05) during EXT across humeral positions. CONCLUSIONS: Force reduction in consequence of fatiguing shoulder loading results in increased scapular muscle activity and minor alterations in scapula motion. Whether even small changes have a clinical impact by creating unfavorable subacromial conditions potentially initiating pain remains unclear.
Background
The anterior cruciate ligament (ACL) rupture can lead to impaired knee function. Reconstruction decreases the mechanical instability but might not have an impact on sensorimotor alterations.
Objective
Evaluation of the sensorimotor function measured with the active joint position sense (JPS) test in anterior cruciate ligament (ACL) reconstructed patients compared to the contralateral side and a healthy control group.
Methods
The databases MEDLINE, CINAHL, EMBASE, PEDro, Cochrane Library and SPORTDiscus were systematically searched from origin until April 2020. Studies published in English, German, French, Spanish or Italian language were included. Evaluation of the sensorimotor performance was restricted to the active joint position sense test in ACL reconstructed participants or healthy controls. The Preferred Items for Systematic Reviews and Meta-Analyses guidelines were followed. Study quality was evaluated using the Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies. Data was descriptively synthesized.
Results
Ten studies were included after application of the selective criteria. Higher angular deviation, reaching significant difference (p < 0.001) in one study, was shown up to three months after surgery in the affected limb. Six months post-operative significantly less error (p < 0.01) was found in the reconstructed leg compared to the contralateral side and healthy controls. One or more years after ACL reconstruction significant differences were inconsistent along the studies.
Conclusions
Altered sensorimotor function was present after ACL reconstruction. Due to inconsistencies and small magnitudes, clinical relevance might be questionable. JPS testing can be performed in acute injured persons and prospective studies could enhance knowledge of sensorimotor function throughout the rehabilitative processes.