Refine
Year of publication
Document Type
- Article (26)
- Conference Proceeding (10)
- Postprint (2)
- Habilitation Thesis (1)
- Other (1)
- Review (1)
Is part of the Bibliography
- yes (41)
Keywords
- sonography (5)
- Achilles tendon (3)
- ECG (2)
- Injury (2)
- Pain occurrence (2)
- Tendinopathy (2)
- Training volume (2)
- Ultrasonography (2)
- Young athletes (2)
- advanced dynamic flow (2)
Institute
- Department Sport- und Gesundheitswissenschaften (41) (remove)
BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly.
Prevalence of Achilles tendinopathy increases with age leading to a weaker tendon with predisposition to rupture. Conclusive evidence of the influence of age and pathology on Achilles tendon (AT) properties remains limited, as previous studies are based on standardized isometric conditions. The study investigates the influence of age and pathology on AT properties during single-leg vertical jump (SLVJ). 10 children (C), 10 asymptomatic adults (A), and 10 tendinopathic patients (T) were included. AT elongation [mm] from rest to maximal displacement during a SLVJ on a force-plate was sonographically assessed. AT compliance [mm/N]) and strain [%] was calculated by dividing elongation by peak ground reaction force [N] and length, respectively. One-way ANOVA followed by Bonferroni post-hoc correction (=0.05) were used to compare C with A and A with T. AT elongation (p=0.004), compliance (p=0.001), and strain were found to be statistically significant higher in C (27 +/- 3mm, 0.026 +/- 0.006[mm/N], 13 +/- 2%) compared to A (21 +/- 4mm, 0.017 +/- 0.005[mm/N], 10 +/- 2%). No statistically significant differences (p0.05) was found between A and T (25 +/- 5mm, 0.019 +/- 0.004[mm/N], 12 +/- 3%). During SLVJ, tendon responded differently in regards to age and pathology with children having the most compliant AT. Higher compliance found in healthy tendons might be considered as a protective factor against load-related injuries.
Sonographically detectable intratendinous blood flow (IBF) is found in 50%-88% of Achilles tendinopathy patients as well as in up to 35% of asymptomatic Achilles tendons (AT). Although IBF is frequently associated with tendon pathology, it may also represent a physiological regulation, for example, due to increased blood flow in response to exercise. Therefore, this study aimed to investigate the acute effects of a standardized running exercise protocol on IBF assessed with Doppler ultrasound (DU) Advanced dynamic flow in healthy ATs. 10 recreationally active adults (5 f, 5m; 29 +/- 3years, 1.72 +/- 0.12m, 68 +/- 16kg, physical activity 206 +/- 145minute/wk) with no history of AT pain and inconspicious tendon structure performed 3 treadmill running tasks on separate days (M1-3) with DU examinations directly before and 5, 30, 60, and 120minutes after exercise. At M1, an incremental exercise test was used to determine the individual anaerobic threshold (IAT). At M2 and M3, participants performed 30-minute submaximal constant load tests (CL1/CL2) with an intensity 5% below IAT. IBF in each tendon was quantified by counting the number of vessels. IBF increased in five ATs from no vessels at baseline to one to four vessels solely detectable 5minutes after CL1 or CL2. One AT had persisting IBF (three vessels) throughout all examinations. Fourteen ATs revealed no IBF at all. Prolonged running led to a physiological, temporary appearance of IBF in 25% of asymptomatic ATs. To avoid exercise-induced IBF in clinical practice, DU examinations should be performed after 30minutes of rest.
Reliability of ultrasound measurements for subcutaneous adipose tissue in elite canoe athletes
(2014)
Background: Data on electrocardiographic and echocardiographic pre-participation screening findings in paediatric athletes are limited.
Methods and results: 10-15 year-old athletes (n = 343) were screened using electro- and echocardiography. The electrocardiogram (ECG) was normal in 220 (64%), mildly abnormal in 108 (31%), and distinctly abnormal in 15 (4%) athletes. Echocardiographic upper reference limits (URL, 97.5 percentile) for the left ventricular (LV) wall thickness in 10-11-year-old boys and girls were 9-10 mm and 8-9 mm, respectively; in 12-13-year-old boys and girls 9-10 mm; and in 14-15-year-old boys and girls 10-11 mm and 9-10 mm, respectively. Three athletes were excluded from competitive sports: one for symptomatic Wolff-Parkinson-White syndrome with a normal echocardiogram; one for negative T-waves in V-1-V-4 and a dilated right ventricle by echocardiography suggestive of (arrhythmogenic) right ventricular disease; and one for normal ECG and biscupid aortic valve including an aneurysm of the ascending aorta detected by echocardiography. Related to echocardiographic findings, the sensitivity and specificity of the ECG to identify cardiovascular abnormalities was 38% and 64%, respectively. The ECG's positive-predictive and negative-predictive values were 13% and 88%, respectively. The numbers needed to screen and calculated costs were 172 for ECG ( 7049), 172 for echocardiography ( 11,530), and 114 combining ECG and echocardiography ( 9323).
Conclusions: Compared to adults, paediatric athletes presented with fewer distinctly abnormal ECGs, and there was no gender difference in paediatric athletes' ECG-pattern distribution. A combination of ECG and echocardiography for pre-participation screening of paediatric athletes is superior to ECG alone but 30% more costly.
In the context of back pain, great emphasis has been placed on the importance of trunk stability, especially in situations requiring compensation of repetitive, intense loading induced during high-performance activities, e.g., jumping or landing. This study aims to evaluate trunk muscle activity during drop jump in adolescent athletes with back pain (BP) compared to athletes without back pain (NBP). Eleven adolescent athletes suffering back pain (BP: m/f: n = 4/7; 15.9 +/- 1.3 y; 176 +/- 11 cm; 68 +/- 11 kg; 12.4 +/- 10.5 h/we training) and 11 matched athletes without back pain (NBP: m/f: n = 4/7; 15.5 +/- 1.3 y; 174 +/- 7 cm; 67 +/- 8 kg; 14.9 +/- 9.5 h/we training) were evaluated. Subjects conducted 3 drop jumps onto a force plate (ground reaction force). Bilateral 12-lead SEMG (surface Electromyography) was applied to assess trunk muscle activity. Ground contact time [ms], maximum vertical jump force [N], jump time [ms] and the jump performance index [m/s] were calculated for drop jumps. SEMG amplitudes (RMS: root mean square [%]) for all 12 single muscles were normalized toMIVC (maximum isometric voluntary contraction) and analyzed in 4 time windows (100 ms pre- and 200 ms post-initial ground contact, 100 ms pre- and 200 ms post-landing) as outcome variables. In addition, muscles were grouped and analyzed in ventral and dorsal muscles, as well as straight and transverse trunk muscles. Drop jump ground reaction force variables did not differ between NBP and BP (p > 0.05). Mm obliquus externus and internus abdominis presented higher SEMG amplitudes (1.3-1.9-fold) for BP (p < 0.05). Mm rectus abdominis, erector spinae thoracic/lumbar and latissimus dorsi did not differ (p > 0.05). The muscle group analysis over the whole jumping cycle showed statistically significantly higher SEMG amplitudes for BP in the ventral (p = 0.031) and transverse muscles (p = 0.020) compared to NBP. Higher activity of transverse, but not straight, trunk muscles might indicate a specific compensation strategy to support trunk stability in athletes with back pain during drop jumps. Therefore, exercises favoring the transverse trunk muscles could be recommended for back pain treatment.
Effects of exercise treatment on functional outcome parameters in mid-portion achilles tendinopathy
(2023)
Exercise interventions are evident in the treatment of mid-portion Achilles tendinopathy (AT). However, there is still a lack of knowledge concerning the effect of different exercise treatments on improving a specific function (e.g., strength) in this population. Thus, this study aimed to systematically review the effect of exercise treatments on different functional outcomes in mid-portion AT. An electronic database of Pubmed, Web of Science, and Cochrane Central Register of Controlled Trials were searched from inception to 21 February 2023. Studies that investigated changes in plantar flexor function with exercise treatments were considered in mid-portion AT. Only randomized controlled trials (RCTs) and clinical controlled trials (CCTs) were included. Functional outcomes were classified by kinetic (e.g., strength), kinematic [e.g., ankle range of motion (ROM)], and sensorimotor (e.g., balance index) parameters. The types of exercise treatments were classified into eccentric, concentric, and combined (eccentric plus concentric) training modes. Quality assessment was appraised using the Physiotherapy Evidence Database scale for RCTs, and the Joanna Briggs Institute scale for CCTs. The search yielded 2,260 records, and a total of ten studies were included. Due to the heterogeneity of the included studies, a qualitative synthesis was performed. Eccentric training led to improvements in power outcomes (e.g., height of countermovement jump), and in strength outcomes (e.g., peak torque). Concentric training regimens showed moderate enhanced power outcomes. Moreover, one high-quality study showed an improvement in the balance index by eccentric training, whereas the application of concentric training did not. Combined training modalities did not lead to improvements in strength and power outcomes. Plantarflexion and dorsiflexion ROM measures did not show relevant changes by the exercise treatments. In conclusion, eccentric training is evident in improving strength outcomes in AT patients. Moreover, it shows moderate evidence improvements in power and the sensorimotor parameter "balance index". Concentric training presents moderate evidence in the power outcomes and can therefore be considered as an alternative to improve this function. Kinematic analysis of plantarflexion and dorsiflexion ROM might not be useful in AT people. This study expands the knowledge what types of exercise regimes should be considered to improve the functional outcomes in AT.
On utilise de plus en plus les tests de verification pour confirmer l'atteinte du consommation d'oxygene maximale (VO(2 max)). Toutefois, le moment et les methodes d'evaluation varient d'un groupe de travail a l'autre. Les objectifs de cette etude sont de constater si on peut administrer un test de verification apres un test d'effort progressif ou s'il est preferable de le faire une autre journee et si on peut determiner le VO(2 max) tout de meme lors de la premiere seance chez des sujets ne repondant pas au critere de verification. Quarante sujets (age, 24 +/- 4 ans; VO(2 max), 50 +/- 7 mL center dot min(-1)center dot kg(-1)) participent a un test d'effort progressif sur tapis roulant et, 10 min plus tard, a un test de verification (VerifDay1) a 110 % de la velocite maximale (v(max)). Le critere de verification est un VO(2) de pointe au VerifDay1 < 5,5 % a la valeur retenue au test d'effort progressif. Les sujets ne repondant pas au critere de verification passent un autre test de verification, mais a 115 % du VerifDay1', et ce, 10 min plus tard pour confirmer le VO(2) de pointe du VerifDay1 en tant que VO(2 max). Tous les autres sujets repassent le VerifDay1 a un jour different (VerifDay2). Six sujets sur quarante ne repondent pas au critere de verification. Chez quatre d'entre eux, on confirme l'atteinte du VO(2 max) au VerifDay1'. Le VO(2) de pointe au VerifDay1 est equivalent a celui du VerifDay2 (3722 +/- 991 mL center dot min(-1) comparativement a 3752 +/- 995 mL center dot min(-1), p = 0,56), mais le temps jusqu'a l'epuisement est significativement plus long au VerifDay2 (2:06 +/- 0:22 min:s comparativement a 2:42 +/- 0:38 min:s, p < 0,001, n = 34). Le VO(2) de pointe obtenu au test de verification ne semble pas conditionne par un test d'effort progressif maximal prealable. On peut donc realiser le test d'effort progressif et le test de verification lors de la meme seance d'evaluation. Chez presque tous les individus ne repondant pas au critere de verification, on peut determiner le VO(2 max) au moyen d'un autre test de verification plus intense.
Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation.
Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm.
Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.