Refine
Document Type
- Article (9)
- Postprint (3)
- Other (2)
- Conference Proceeding (1)
Language
- English (15)
Is part of the Bibliography
- yes (15)
Keywords
- diagnostic techniques and procedures (2)
- eccentric (2)
- exercise (2)
- exercise induced muscle damage (2)
- inflammation (2)
- interleukin-6 (2)
- internleukin-10 (2)
- isokinetics (2)
- kinematics (2)
- muscle fatigue (2)
- repeated bout effect (2)
- shoulder joint (2)
- trunk muscles (2)
- tumor necrosis factor-α (2)
- validation study (2)
- wearable devices (2)
- Isokinetics (1)
- Motion analysis (1)
- Scapular dyskinesis (1)
- Scapulohumeral rhythm (1)
- Scapulothoracic (1)
- advanced dynamic flow (1)
- electromyography (1)
- intratendinous blood flow (1)
- isokinetic testing (1)
- musculoskeletal (1)
- reliability (1)
- scapular muscle activity (1)
- shoulder (1)
- ultrasound (1)
Background and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 +/- 4 years, height 177 +/- 11 cm, weight 73 +/- 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficients (ICC), root mean square error (RMSE) and Bland and Altmann analysis (bias; upper and lower limits of agreement). Results ROM and TROM analysis revealed inconsistent validity during simple (ICC: 0.040-0.733, RMSE: 9.7 degrees-20.3 degrees, bias: 1.2 degrees-50.7 degrees) and insufficient agreement during complex shoulder movements (ICC: 0.104-0.453, RMSE: 10.1 degrees-23.3 degrees, bias: 1.0 degrees-55.9 degrees). Peak angular velocity (ICC: 0.202-0.865, RMSE: 14.6 degrees/s-26.7 degrees/s, bias: 10.2 degrees/s-29.9 degrees/s) and mean angular velocity (ICC: 0.019-0.786, RMSE:6.1 degrees/s-34.2 degrees/s, bias: 1.6 degrees/s-27.8 degrees/s) were inconsistent. Conclusions The "off-the-shelf" sensor-software system showed overall insufficient agreement with the gold standard. Further development of commercial IMU-software-solutions may increase measurement accuracy and permit their integration into everyday clinical practice.
The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended.
Background and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 +/- 4 years, height 177 +/- 11 cm, weight 73 +/- 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficients (ICC), root mean square error (RMSE) and Bland and Altmann analysis (bias; upper and lower limits of agreement). Results ROM and TROM analysis revealed inconsistent validity during simple (ICC: 0.040-0.733, RMSE: 9.7 degrees-20.3 degrees, bias: 1.2 degrees-50.7 degrees) and insufficient agreement during complex shoulder movements (ICC: 0.104-0.453, RMSE: 10.1 degrees-23.3 degrees, bias: 1.0 degrees-55.9 degrees). Peak angular velocity (ICC: 0.202-0.865, RMSE: 14.6 degrees/s-26.7 degrees/s, bias: 10.2 degrees/s-29.9 degrees/s) and mean angular velocity (ICC: 0.019-0.786, RMSE:6.1 degrees/s-34.2 degrees/s, bias: 1.6 degrees/s-27.8 degrees/s) were inconsistent. Conclusions The "off-the-shelf" sensor-software system showed overall insufficient agreement with the gold standard. Further development of commercial IMU-software-solutions may increase measurement accuracy and permit their integration into everyday clinical practice.
Altered scapular muscle activity is mostly described under unloaded and submaximal loaded conditions in impingement patients. However, there is no clear evidence on muscle activity with respect to movement phases under maximum load in healthy subjects. Therefore, this study aimed to investigate scapular muscle activity under unloaded and maximum loaded isokinetic shoulder flexion and extension in regard to the movement phase. Fourteen adults performed unloaded (continuous passive motion [CPM]) as well as maximum loaded (concentric [CON], eccentric [ECC]) isokinetic shoulder flexion (Flex) and extension (Ext). Simultaneously, scapular muscle activity was measured by EMG. Root mean square was calculated for the whole ROM and four movement phases. Data were analyzed descriptively and by two-way repeated measures ANOVA. CPMFlex resulted in a linear increase of muscle activity for all muscles. Muscle activity during CONFlex and ECCFlex resulted in either constant activity levels or in an initial increase followed by a plateau in the second half of movement. CPMExt decreased with the progression of movement, whereas CONExt and ECCExt initially decreased and either levelled off or increased in the second half of movement. Scapular muscle activity of unloaded shoulder flexion and extension changed under maximum load showing increased activity levels and an altered pattern over the course of movement.
Physical activity and exercise are effective approaches in prevention and therapy of multiple diseases. Although the specific characteristics of lengthening contractions have the potential to be beneficial in many clinical conditions, eccentric training is not commonly used in clinical populations with metabolic, orthopaedic, or neurologic conditions. The purpose of this pilot study is to investigate the feasibility, functional benefits, and systemic responses of an eccentric exercise program focused on the trunk and lower extremities in people with low back pain (LBP) and multiple sclerosis (MS). A six-week eccentric training program with three weekly sessions is performed by people with LBP and MS. The program consists of ten exercises addressing strength of the trunk and lower extremities. The study follows a four-group design (N = 12 per group) in two study centers (Israel and Germany): three groups perform the eccentric training program: A) control group (healthy, asymptomatic); B) people with LBP; C) people with MS; group D (people with MS) receives standard care physiotherapy. Baseline measurements are conducted before first training, post-measurement takes place after the last session both comprise blood sampling, self-reported questionnaires, mobility, balance, and strength testing. The feasibility of the eccentric training program will be evaluated using quantitative and qualitative measures related to the study process, compliance and adherence, safety, and overall program assessment. For preliminary assessment of potential intervention effects, surrogate parameters related to mobility, postural control, muscle strength and systemic effects are assessed. The presented study will add knowledge regarding safety, feasibility, and initial effects of eccentric training in people with orthopaedic and neurological conditions. The simple exercises, that are easily modifiable in complexity and intensity, are likely beneficial to other populations. Thus, multiple applications and implementation pathways for the herein presented training program are conceivable.
Eccentric exercise is discussed as a treatment option for clinical populations, but specific responses in terms of muscle damage and systemic inflammation after repeated loading of large muscle groups have not been conclusively characterized. Therefore, this study tested the feasibility of an isokinetic protocol for repeated maximum eccentric loading of the trunk muscles. Nine asymptomatic participants (5 f/4 m; 34±6 yrs; 175±13 cm; 76±17 kg) performed three isokinetic 2-minute all-out trunk strength tests (1x concentric (CON), 2x eccentric (ECC1, ECC2), 2 weeks apart; flexion/extension, 60°/s, ROM 55°). Outcomes were peak torque, torque decline, total work, and indicators of muscle damage and inflammation (over 168 h). Statistics were done using the Friedman test (Dunn’s post-test). For ECC1 and ECC2, peak torque and total work were increased and torque decline reduced compared to CON. Repeated ECC bouts yielded unaltered torque and work outcomes. Muscle damage markers were highest after ECC1 (soreness 48 h, creatine kinase 72 h; p<0.05). Their overall responses (area under the curve) were abolished post-ECC2 compared to post-ECC1 (p<0.05). Interleukin-6 was higher post-ECC1 than CON, and attenuated post-ECC2 (p>0.05). Interleukin-10 and tumor necrosis factor-α were not detectable. All markers showed high inter-individual variability. The protocol was feasible to induce muscle damage indicators after exercising a large muscle group, but the pilot results indicated only weak systemic inflammatory responses in asymptomatic adults.
Flexion-extension ratio of trunk peak torque measures and antagonistic activity in males and females
(2014)
Eccentric exercise is discussed as a treatment option for clinical populations, but specific responses in terms of muscle damage and systemic inflammation after repeated loading of large muscle groups have not been conclusively characterized. Therefore, this study tested the feasibility of an isokinetic protocol for repeated maximum eccentric loading of the trunk muscles. Nine asymptomatic participants (5 f/4 m; 34±6 yrs; 175±13 cm; 76±17 kg) performed three isokinetic 2-minute all-out trunk strength tests (1x concentric (CON), 2x eccentric (ECC1, ECC2), 2 weeks apart; flexion/extension, 60°/s, ROM 55°). Outcomes were peak torque, torque decline, total work, and indicators of muscle damage and inflammation (over 168 h). Statistics were done using the Friedman test (Dunn’s post-test). For ECC1 and ECC2, peak torque and total work were increased and torque decline reduced compared to CON. Repeated ECC bouts yielded unaltered torque and work outcomes. Muscle damage markers were highest after ECC1 (soreness 48 h, creatine kinase 72 h; p<0.05). Their overall responses (area under the curve) were abolished post-ECC2 compared to post-ECC1 (p<0.05). Interleukin-6 was higher post-ECC1 than CON, and attenuated post-ECC2 (p>0.05). Interleukin-10 and tumor necrosis factor-α were not detectable. All markers showed high inter-individual variability. The protocol was feasible to induce muscle damage indicators after exercising a large muscle group, but the pilot results indicated only weak systemic inflammatory responses in asymptomatic adults.
Characterization of scapular kinematics under demanding load conditions might aid to distinguish between physiological and clinically relevant alterations. Previous investigations focused only on submaximal external load situations. How scapular movement changes with maximal load remains unclear. Therefore, the present study aimed to evaluate 3D scapular kinematics during unloaded and maximal loaded shoulder flexion and extension. Twelve asymptomatic individuals performed shoulder flexion and extension movements under unloaded and maximal concentric and eccentric loaded isokinetic conditions. 3D scapular kinematics assessed with a motion capture system was analyzed for 20° intervals of humeral positions from 20° to 120° flexion. Repeated measures ANOVAs were used to evaluate kinematic differences between load conditions for scapular position angles, scapulohumeral rhythm and scapular motion extent. Increased scapular upward rotation was seen during shoulder flexion and extension as well as decreased posterior tilt and external rotation during eccentric and concentric arm descents of maximal loaded compared to unloaded conditions. Load effects were further seen for the scapulohumeral rhythm with greater scapular involvement at lower humeral positions and increased scapular motion extent under maximal loaded shoulder movements. With maximal load applied to the arm physiological scapular movement pattern are induced that may imply both impingement sparing and causing mechanisms.
Eccentric exercises (ECC) induce reversible muscle damage, delayed-onset muscle soreness and an inflammatory reaction that is often followed by a systemic anti-inflammatory response. Thus, ECC might be beneficial for treatment of metabolic disorders which are frequently accompanied by a low-grade systemic inflammation. However, extent and time course of a systemic immune response after repeated ECC bouts are poorly characterized.
PURPOSE: To analyze the (anti-)inflammatory response after repeated ECC loading of the trunk.
METHODS: Ten healthy participants (33 ± 6 y; 173 ± 14 cm; 74 ± 16 kg) performed three isokinetic strength measurements of the trunk (concentric (CON), ECC1, ECC2, each 2 wks apart; flexion/extension, velocity 60°/s, 120s MVC). Pre- and 4, 24, 48, 72, 168h post-exercise, muscle soreness (numeric rating scale, NRS) was assessed and blood samples were taken and analyzed [Creatine kinase (CK), C-reactive protein (CRP), Interleukin-6 (IL-6), IL-10, Tumor necrosis factor-α (TNF-α)]. Statistics were done by Friedman‘s test with Dunn‘s post hoc test (α=.05).
RESULTS: Mean peak torque was higher during ECC1 (319 ± 142 Nm) than during CON (268 ± 108 Nm; p<.05) and not different between ECC1 and ECC2 (297 ± 126 Nm; p>.05). Markers of muscle damage (peaks post-ECC1: NRS 48h, 4.4±2.9; CK 72h, 14407 ± 19991 U/l) were higher after ECC1 than after CON and ECC2 (p<.05). The responses over 72h (stated as Area under the Curve, AUC) were abolished after ECC2 compared to ECC1 (p<.05) indicating the presence of the repeated bout effect. CRP levels were not changed. IL-6 levels increased 2-fold post-ECC1 (pre: 0.5 ± 0.4 vs. 72h: 1.0 ± 0.8 pg/ml). The IL-6 response was enhanced after ECC1 (AUC 61 ± 37 pg/ml*72h) compared to CON (AUC 33 ± 31 pg/ml*72h; p<.05). After ECC2, the IL-6 response (AUC 43 ± 25 pg/ml*72h) remained lower than post-ECC1, but the difference was not statistically significant. Serum levels of TNF-α and of the anti-inflammatory cytokine IL-10 were below detection limits. Overall, markers of muscle damage and immune response showed high inter-individual variability.
CONCLUSION: Despite maximal ECC loading of a large muscle group, no anti-inflammatory and just weak inflammatory responses were detected in healthy adults. Whether ECC elicits a different reaction in inflammatory clinical conditions is unclear.