We sought to investigate the effects of wearing a mobile respiratory gas analysis system during a treadmill test on blood lactate (bLa) concentrations and commonly applied bLa thresholds. A total of 16 recreational athletes (31 +/- 3 years, V0205: 58 6 ml min(-1)-kg(-1)) performed one multistage treadmill test with and one without gas exchange measurements (GEM and noGEM). The whole bLa curve, the lactate threshold (LT), the individual anaerobic thresholds according to Stegmann(IAT(sr)) and Dickhuth (IAT(Di)), and a fixed bLa concentration of 4 mmob.l(-1) (OBLA) were evaluated. The bLa curve was shifted slightly leftward in GEM compared to noGEM (P<0.05), whereas the heart rate response was not different between conditions (P= 0.89). There was no difference between GEM and noGEM for LT (2.61 +/- 0.34 vs. 2.64 +/- 0.39 m(-1) s(-1) P=0.49) and IAT(st) (3.47 +/- 0.42 vs. 3.55 +/- 0.47m-s(-1), P=0.12). However, IATD(Di) (3.57 +/- 0.39 vs. 3.66 +/- 0.44m-s(-1), P<0.01) and OBLA (3.85 +/- 0.46 vs. 3.96 +/- 0.47m-s-1, P<0.01) occurred at slower running velocities in GEM. The bLa response to treadmill tests is mildly affected by wearing a mobile gas analysis system. This also applies to bLa thresholds located at higher exercise intensities. While the magnitude of the effects is of little importance for recreational athletes, it might be relevant for elite athletes and scientific studies.
The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended.