Refine
Year of publication
Document Type
- Article (57)
- Postprint (2)
- Conference Proceeding (1)
Language
- English (60) (remove)
Is part of the Bibliography
- yes (60)
Keywords
- cyclic voltammetry (3)
- cytochrome c (2)
- 3D electrode structures (1)
- Bioelectrocatalysis (1)
- DMSO (1)
- DNA (1)
- Direct electron transfer (1)
- IR ellipsometry (1)
- Immobilization (1)
- PQQ-GDH (1)
In this work, the fabrication and characterization of a simple, inexpensive, and effective microfluidic paper analytic device (mu PAD) for monitoring DNA samples is reported. The glass microfiber-based chip has been fabricated by a new wax-based transfer-printing technique and an electrode printing process. It is capable of moving DNA effectively in a time-dependent fashion. The nucleic acid sample is not damaged by this process and is accumulated in front of the anode, but not directly on the electrode. Thus, further DNA processing is feasible. The system allows the DNA to be purified by separating it from other components in sample mixtures such as proteins. Furthermore, it is demonstrated that DNA can be moved through several layers of the glass fiber material. This proof of concept will provide the basis for the development of rapid test systems, e.g., for the detection of pathogens in water samples.
The combination of the biocatalytic features of enzymes with the unique physical properties of nanoparticles in a biohybrid system provides a promising approach for the development of advanced bioelectrocatalytic devices. This study describes the construction of photoelectrochemical signal chains based on CdSe/ZnS quantum dot (QD) modified gold electrodes as light switchable elements, and low molecular weight redox molecules for the combination with different biocatalysts. Photoelectrochemical and photoluminescence experiments verify that electron transfer can be achieved between the redox molecules hexacyanoferrate and ferrocene, and the QDs under illumination. Since for both redox mediators a concentration dependent photocurrent change has been found, light switchable enzymatic signal chains are built up with fructose dehydrogenase (FDH) and pyrroloquinoline quinone-dependent glucose dehydrogenase ((PQQ) GDH) for the detection of sugars. After immobilization of the enzymes at the QD electrode the biocatalytic oxidation of the substrates can be followed by conversion of the redox mediator in solution and subsequent detection at the QD electrode. Furthermore, (PQQ) GDH has been assembled together with ferrocenecarboxylic acid on top of the QD electrode for the construction of a funtional biohybrid architecture, showing that electron transfer can be realized from the enzyme over the redox mediator to the QDs and subsequently to the electrode in a completely immobilized fashion. The results obtained here do not only provide the basis for light-switchable biosensing and bioelectrocatalytic applications, but may also open the way for self-driven point-of-care systems by combination with solar cell approaches (power generation at the QD electrode by enzymatic substrate consumption).
This study introduces a thermally responsive, polymer-based electrode system. The key component is a surface-attached, temperature-responsive poly(oligoethylene glycol) methacrylate (poly(OEGMA)) type polymer bearing photoreactive benzophenone and carboxy groups containing side chains. The responsive behavior of the polymer in aqueous media has been investigated by turbidimetry measurements. Polymer films are formed on gold substrates by means of the photoreactive 2(dicyclohexylphosphino)benzophenone (DPBP) through photocrosslinking. The electrochemical behavior of the resulting polymer-substrate interface has been investigated in buffered [Fe(CN)6](3-)/[Fe (CN)6](4-)solutions at room temperature and under temperature variation by cyclic voltammetry (CV). The CV experiments show that with increasing temperature structural changes of the polymer layer occur, which alter the output of the electrochemical measurement. Repeated heating/cooling cycles analyzed by CV measurements and pH changes analyzed by quartz crystal microbalance with dissipation monitoring (QCM-D) reveal the reversible nature of the restructuring process. The immobilized films are further modified by covalent coupling of two small biomolecules - a hydrophobic peptide and a more hydrophilic one. These attached components influence the hydrophobicity of the layer in a different way the resulting change of the temperature-caused behavior has been studied by CV indicating a different state of the polymer after coupling of the hydrophobic peptide.
An efficient electrocatalytic biosensor for sulfite detection was developed by co-immobilizing sulfite oxidase and cytochrome c with polyaniline sulfonic acid in a layer-by-layer assembly. QCM, UV-Vis spectroscopy and cyclic voltammetry revealed increasing loading of electrochemically active protein with the formation of multilayers. The sensor operates reagentless at low working potential. A catalytic oxidation current was detected in the presence of sulfite at the modified gold electrode, polarized at +0.1 V ( vs. Ag/AgCl 1 M KCl). The stability of the biosensor performance was characterized and optimized. A 17-bilayer electrode has a linear range between 1 and 60 mu M sulfite with a sensitivity of 2.19 mA M-1 sulfite and a response time of 2 min. The electrode retained a stable response for 3 days with a serial reproducibility of 3.8% and lost 20% of sensitivity after 5 days of operation. It is possible to store the sensor in a dry state for more than 2 months. The multilayer electrode was used for determination of sulfite in unspiked and spiked samples of red and white wine. The recovery and the specificity of the signals were evaluated for each sample.
A cysteine mutant of a monomeric human Cu, Zn-SOD (Glycine 61, Serine 142) has been immobilized directly on gold electrodes using the thiol groups introduced. The electrochemical behavior of the surface confined protein was studied in mixtures of aqueous buffer and DMSO up to an organic solvent content of 60%. The formal potential was found to be rather independent of the DMSO content. However, half peak width increased and the redoxactive amount clearly decreased with raising DMSO content. In addition, the kinetics of the heterogeneous electron transfer became slower; but still a quasireversible electrochemical conversion of the mutant SOD was feasible. Thus, the electrodes were applied for sensorial superoxide detection. At a potential of +220 mV vs. Ag/AgCl advantage was taken of the partial oxidation reaction of the enzyme. A defined superoxide signal was obtained in solutions up to 40% DMSO. The sensitivity of the mutant electrodes decreased linearly with the organic solvent content in solution but was still higher compared to conventional cyt.c based sensors. At DMSO concentrations higher than 40% no sensor response was detected.
A fluidic chip system was developed, which combines a stable generation of superoxide radicals and hydrogen peroxide with their sensorial detection. The generation of both reactive oxygen species was achieved by immobilization of xanthine oxidase on controlled pore glass in a reaction chamber. Antioxidants can be introduced into the fluidic chip system by means of mixing chamber. The detection of both species is based on the amperometric principle using a biosensor chip with two working electrodes. As sensing protein for both electrodes cytochrome c was used. The novel system was designed for the quantification of the antioxidant efficiency of different potential scavengers of the respective reactive species in an aqueous medium. Several model antioxidants such as ascorbic acid or catalase have been tested under flow conditions.
The creation of electron transfer (ET) chains based on the defined arrangement of enzymes and redox proteins on electrode surfaces represents an interesting approach within the field of bioelectrocatalysis. In this study, we investigated the ET reaction of the flavin-dependent enzyme fructose dehydrogenase (FDH) with the redox protein cytochrome c (cyt c). Two different pH optima were found for the reaction in acidic and neutral solutions. When cyt c was adsorbed on an electrode surface while the enzyme remained in solution, ET proceeded efficiently in media of neutral pH. Interprotein ET was also observed in acidic media; however, it appeared to be less efficient. These findings suggest that two different ET pathways between the enzyme and cyt c may occur. Moreover, cyt c and FDH were immobilized in multiple layers on an electrode surface by means of another biomacromolecule: DNA (double stranded) using the layer -by -layer technique. The biprotein multilayer architecture showed a catalytic response in dependence on the fructose concentration, indicating that the ET reaction between both proteins is feasible even in the immobilized state. The electrode showed a defined response to fructose and a good storage stability. Our results contribute to the better understanding of the ET reaction between FDH and cyt c and provide the basis for the creation of all-biomolecule based fructose sensors the sensitivity of which can be controlled by the layer preparation.
We report on the pH-dependent bioelectrocatalytic activity of the redox enzyme xanthine dehydrogenase (XDH) in the presence of sulfonated polyaniline PMSA1 (poly(2-methoxyaniline-5-sulfonic acid)-co-aniline). Ultraviolet-visible (UV-vis) spectroscopic measurements with both components in solution reveal electron transfer from the hypoxanthine (HX)-reduced enzyme to the polymer. The enzyme shows bioelectrocatalytic activity on indium tin oxide (ITO) electrodes, when the polymer is present. Depending on solution pH, different processes can be identified. It can be demonstrated that not only product-based communication with the electrode but also efficient polymer-supported bioelectrocatalysis occur. Interestingly, substrate dependent catalytic currents can be obtained in acidic and neutral solutions, although the highest activity of XDH with natural reaction partners is in the alkaline region. Furthermore, operation of the enzyme electrode without addition of the natural cofactor of XDH is feasible. Finally, macroporous ITO electrodes have been used as an immobilization platform for the fabrication of HX-sensitive electrodes. The study shows that the efficient polymer/enzyme interaction can be advantageously combined with the open structure of an electrode material of controlled pore size, resulting in good processability, stability, and defined signal transfer in the presence of a substrate.
This study reports on the investigation of a thermoresponsive polymer as a thin film on electrodes and the influence of coupling a peptide and an antibody to the film. The utilized polymer from the class of poly(oligoethylene glycol)-methacrylate polymers (poly(OEGMA)) with carboxy functions containing side chains was synthesized and properly characterized in aqueous solutions. The dependence of the cloud point on the pH of the surrounding media is discussed. The responsive polymer was immobilized on gold electrodes as shown by electrochemical, quartz crystal microbalance (QCM), and atomic force microscopy (AFM) techniques. The temperature dependent behavior of the polymer covalently grafted to gold substrates is investigated using cyclic voltammetry (CV) in ferro-/ferricyanide solution. Significant changes in the slope of the temperature-dependence of the voltammetric peak current and the peak separation values clearly indicate the thermally induced conformational change on the surface. Finally, a biorecognition reaction between a short FLAG peptide (N-Asp-Tyr-Lys-Asp-Asp-Asp-Asp-Lys-C) covalently immobilized on the polymer interface and the corresponding IgG antibody was performed. The study shows that the responsiveness of the electrode is retained after peptide coupling and antibody binding, although the response is diminished.
A feasible approach to construct multilayer films of sulfonated polyanilines - PMSA1 and PABMSA1 containing different ratios of aniline, 2-methoxyaniline-5-sulfonic acid (MAS) and 3-aminobenzoic acid (AB), with the entrapped redox enzyme pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQ-GDH) on Au and ITO electrode surfaces, is described. The formation of layers has been followed and confirmed by electrochemical impedance spectroscopy (EIS), which demonstrates that the multilayer assembly can be achieved in a progressive and uniform manner. The gold and ITO electrodes subsequently modified with PMSA1:PQQ-GDH and PABMSA1 films are studied by cyclic voltammetry (CV) and UV-Vis spectroscopy which show a significant direct bioelectrocatalytical response to the oxidation of the substrate glucose without any additional mediator. This response correlates linearly with the number of deposited layers. Furthermore, the constructed polymer/enzyme multilayer system exhibits a rather good long-term stability, since the catalytic current response is maintained for more than 60% of the initial value even after two weeks of storage. This verifies that a productive interaction of the enzyme embedded in the film of substituted polyaniline can be used as a basis for the construction of bioelectronic units, which are useful as indicators for processes liberating glucose and allowing optical and electrochemical transduction.