Refine
Has Fulltext
- yes (2)
Year of publication
- 2010 (2) (remove)
Document Type
- Doctoral Thesis (2)
Is part of the Bibliography
- yes (2) (remove)
Keywords
- synchrotron radiation (2) (remove)
Institute
This thesis is focused on the electronic, spin-dependent and dynamical properties of thin magnetic systems. Photoemission-related techniques are combined with synchrotron radiation to study the spin-dependent properties of these systems in the energy and time domains. In the first part of this thesis, the strength of electron correlation effects in the spin-dependent electronic structure of ferromagnetic bcc Fe(110) and hcp Co(0001) is investigated by means of spin- and angle-resolved photoemission spectroscopy. The experimental results are compared to theoretical calculations within the three-body scattering approximation and within the dynamical mean-field theory, together with one-step model calculations of the photoemission process. From this comparison it is demonstrated that the present state of the art many-body calculations, although improving the description of correlation effects in Fe and Co, give too small mass renormalizations and scattering rates thus demanding more refined many-body theories including nonlocal fluctuations. In the second part, it is shown in detail monitoring by photoelectron spectroscopy how graphene can be grown by chemical vapour deposition on the transition-metal surfaces Ni(111) and Co(0001) and intercalated by a monoatomic layer of Au. For both systems, a linear E(k) dispersion of massless Dirac fermions is observed in the graphene pi-band in the vicinity of the Fermi energy. Spin-resolved photoemission from the graphene pi-band shows that the ferromagnetic polarization of graphene/Ni(111) and graphene/Co(0001) is negligible and that graphene on Ni(111) is after intercalation of Au spin-orbit split by the Rashba effect. In the last part, a time-resolved x-ray magnetic circular dichroic-photoelectron emission microscopy study of a permalloy platelet comprising three cross-tie domain walls is presented. It is shown how a fast picosecond magnetic response in the precessional motion of the magnetization can be induced by means of a laser-excited photoswitch. From a comparision to micromagnetic calculations it is demonstrated that the relatively high precessional frequency observed in the experiments is directly linked to the nature of the vortex/antivortex dynamics and its response to the magnetic perturbation. This includes the time-dependent reversal of the vortex core polarization, a process which is beyond the limit of detection in the present experiments.
In dieser Arbeit wurden die Möglichkeiten und Grenzen für Zirkulardichroismus-Messungen mit Synchrotronstrahlung untersucht. Dazu wurde ein Messaufbau für Zirkulardichroismus-Messungen an zwei Strahlrohren am Berliner Elektronenspeicherring für Synchrotronstrahlung eingesetzt, die für Messungen im Bereich des ultravioletten Lichts geeignet sind. Eigenschaften der Strahlrohre und des Messaufbau wurden in einigen wichtigen Punkten mit kommerziellen Zirkulardichroismus-Spektrometern verglichen. Der Schwerpunkt lag auf der Ausdehnung des zugänglichen Wellenlängenbereichs unterhalb von 180 nm zur Untersuchung des Zirkulardichroismus von Proteinen in diesem Bereich. In diesem Bereich ist es nicht nur die Lichtquelle sondern vor allem die Absorption des Lichts durch Wasser, die den Messbereich bei der Messung biologischer Proben in wässriger Lösung einschränkt. Es wurden Bedingungen gefunden, unter denen der Messbereich auf etwa 160 nm, in einigen Fällen bis auf 130 nm ausgedehnt werden konnte. Dazu musste die Pfadlänge deutlich reduziert werden und verschieden Probenküvetten wurden getestet. Der Einfluss der dabei auftretenden Spannungsdoppelbrechung in den Probenküvetten auf das Messsignal konnte mit einem alternativen Messaufbau deutlich reduziert werden. Systematische Fehler im Messsignal und auftretende Strahlenschäden begrenzen jedoch die Zuverlässigkeit der gemessenen Spektren. Bei Proteinfilmen schränkt die Absorption von Wasser den Messbereich kaum ein. Es wurden jedoch meist deutliche Unterschiede zwischen den Spektren von Proteinfilmen und den Spektren von Proteinen in wässriger Lösung festgestellt. Solange diese Unterschiede nicht minimiert werden können, stellen Proteinfilme keine praktikable Alternative zu Messungen in wässriger Lösung dar.