Refine
Has Fulltext
- no (16)
Document Type
- Article (16) (remove)
Language
- English (16)
Is part of the Bibliography
- yes (16) (remove)
Keywords
- reliability (16) (remove)
Institute
- Department Sport- und Gesundheitswissenschaften (4)
- Fakultät für Gesundheitswissenschaften (2)
- Institut für Ernährungswissenschaft (2)
- Department Linguistik (1)
- Department Psychologie (1)
- Hasso-Plattner-Institut für Digital Engineering GmbH (1)
- Hasso-Plattner-Institut für Digital Engineering gGmbH (1)
- Hochschulambulanz (1)
- Humanwissenschaftliche Fakultät (1)
- Institut für Chemie (1)
Using two clinical samples of patients, the presented studies examined the construct validity of the recently revised Anxiety Sensitivity Index-3 (ASI-3). Confirmatory factor analyses established a clear three-factor structure that corresponds to the postulated subdivision of the construct into correlated somatic, social, and cognitive components. Participants with different primary clinical diagnoses differed from each other on the ASI-3 subscales in theoretically meaningful ways. Specifically, the ASI-3 successfully discriminated patients with anxiety disorders from patients with nonanxiety disorders. Moreover, patients with panic disorder or agoraphobia manifested more somatic concerns than patients with other anxiety disorders and patients with nonanxiety disorders. Finally, correlations of the ASI-3 scales with other measures of clinical symptoms and negative affect substantiated convergent and discriminant validity. Substantial positive correlations were found between the ASI-3 Somatic Concerns and body vigilance, between Social Concerns and fear of negative evaluation and socially inhibited behavior, and between Cognitive Concerns and depression symptoms, anxiety, fear of negative evaluation, and subjective complaints. Moreover, Social Concerns correlated negatively with dominant and intrusive behavior. Results are discussed with respect to the contribution of the ASI-3 to the assessment of anxiety-related disorders.
Reliability tests for wavelength-stabilized compact diode laser systems emitting at 671 nm are presented. The devices were mounted on microoptical benches with the dimensions of 13 mm x 4 mm. Reflecting Bragg gratings were used for wavelength stabilization and emission width narrowing. The reliability tests were performed at 25 degrees C and at an output power up to 10 mW per micrometer stripe width of the gain medium. Reliable operation could be demonstrated over a test time up to 14 500 h at an output power up to 1.0 W. Environmental tests using random vibrations with acceleration up to 29 g were performed without deterioration of the devices.
This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.
The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended.
Accuracy of training recommendations based on a treadmill multistage incremental exercise test
(2018)
Competitive runners will occasionally undergo exercise in a laboratory setting to obtain predictive and prescriptive information regarding their performance. The present research aimed to assess whether the physiological demands of lab-based treadmill running (TM) can simulate that of over-ground (OG) running using a commonly used protocol. Fifteen healthy volunteers with a weekly mileage of ≥ 20 km over the past 6 months and treadmill experience participated in this cross-sectional study. Two stepwise incremental tests until volitional exhaustion was performed in a fixed order within one week in an Outpatient Clinic research laboratory and outdoor athletic track. Running velocity (IATspeed), heart rate (IATHR) and lactate concentration at the individual anaerobic threshold (IATbLa) were primary endpoints. Additionally, distance covered (DIST), maximal heart rate (HRmax), maximal blood lactate concentration (bLamax) and rate of perceived exertion (RPE) at IATspeed were analyzed. IATspeed, DIST and HRmax were not statistically significantly different between conditions, whereas bLamax and RPE at IATspeed showed statistical significance (p < 0.05). Apart from RPE at IATspeed, IATspeed, DIST, HRmax and bLamax strongly correlate between conditions (r = 0.815–0.988). High reliability between conditions provides strong evidence to suggest that running on a treadmill are physiologically comparable to that of OG and that training recommendations and be made with assurance.
The Test of Masticating and Swallowing Solids (TOMASS) is a validated assessment tool measuring the efficiency of solid bolus intake by four quantitative parameters: discrete bites, masticatory cycles, swallows and time to ingest a single cracker. A normative database for adults (20-80+ years) has previously been established. The objective of this study was to investigate the applicability and reliability of the TOMASS in children and adolescents (TOMASS-C) and to establish the normative database for this younger population. We collected data from 638 participants (male: 311, female: 327) in five age groups (4-18 years) with five different but very similar test crackers in four countries. Significant effects of bolus type (cracker), age group and gender on the TOMASS parameters were identified, requiring stratification of the TOMASS-C database by these variables. Intra-rater reliability was excellent (ICC > 0.94) for all parameters; inter-rater reliability was moderate for "number of swallows" (ICC = 0.54), good for "bites" (ICC = 0.78) and "time" (ICC = 0.82), and excellent for "masticatory cycles" (ICC = 0.96). The "Test of Masticating and Swallowing Solids in Children (TOMASS-C)" was identified to be a reliable diagnostic tool for the comprehensive measurement of discrete oral stage components of solid bolus ingestion, standardised by a large normative database that covers age groups from preschoolers to young adults. While differences between gender groups were less pronounced than in the adult population, previous results relating to changes in masticatory and swallowing as a function of age are confirmed by our data.
Our experimental approach included two studies to determine discriminative validity and test-retest reliability (study 1) as well as ecological validity (study 2) of a judo ergometer system while performing judo-specific movements. Sixteen elite (age: 23 +/- 3 years) and 11 sub-elite (age: 16 +/- 1 years) athletes participated in study 1 and 14 male sub-elite judo athletes participated in study 2. Discriminative validity and test-retest reliability of sport-specific parameters (mechanical work, maximal force) were assessed during pulling movements with and without tsukuri (kuzushi). Ecological validity of muscle activity was determined by performing pulling movements using the ergometer without tsukuri and during the same movements against an opponent. In both conditions, electromyographic activity of trunk (e.g., m. erector spinae) and upper limb muscles (e.g., m. biceps brachii) were assessed separately for the lifting and pulling arm. Elite athletes showed mostly better mechanical work, maximal force, and power (0.12 <= d <= 1.80) compared with sub-elite athletes. The receiver operating characteristic analysis revealed acceptable validity of the JERGo(C) system to discriminate athletes of different performance levels predominantly during kuzushi without tsukuri (area under the curve = 0.27-0.90). Moreover, small-to-medium discriminative validity was found to detect meaningful performance changes for mechanical work and maximal force. The JERGo(C) system showed small-to-high relative (ICC = 0.37-0.92) and absolute reliability (SEM = 10.8-18.8%). Finally, our analyses revealed acceptable correlations (r = 0.41-0.88) between muscle activity during kuzushi performed with the JERGo(C) system compared with a judo opponent. Our findings indicate that the JERGo(C) system is a valid and reliable test instrument for the assessment and training of judo-specific pulling kinetics particularly during kuzushi movement without tsukuri.
Internet connectivity of cloud services is of exceptional importance for both their providers and consumers. This article demonstrates the outlines of a method for measuring cloud-service connectivity at the internet protocol level from a client's perspective. For this, we actively collect connectivity data via traceroute measurements from PlanetLab to several major cloud services. Furthermore, we construct graph models from the collected data, and analyse the connectivity of the services based on important graph-based measures. Then, random and targeted node removal attacks are simulated, and the corresponding vulnerability of cloud services is evaluated. Our results indicate that cloud service hosts are, on average, much better connected than average hosts. However, when interconnecting nodes are removed in a targeted manner, cloud connectivity is dramatically reduced.
As research on sexual aggression has been growing, methodological issues in assessing prevalence rates have received increased attention. Building on work by Abbey and colleagues about effects of question format, participants in this study (1,253; 621 female; 632 male) were randomly assigned to one of two versions of the Sexual Aggression and Victimization Scale (SAV-S). In Version 1, the coercive tactic (use/threat of physical force, exploitation of the inability to resist, verbal pressure) was presented first, and sexual acts (sexual touch, attempted and completed sexual intercourse, other sexual acts) were presented as subsequent questions. In Version 2, sexual acts were presented first, and coercive tactics as subsequent questions. No version effects emerged for overall perpetration rates reported by men and women. The overall victimization rate across all items was significantly higher in the tactic-first than in the sexual-act-first conditions for women, but not for men. Classifying participants by their most severe experience of sexual victimization showed that fewer women were in the nonvictim category and more men were in the nonconsensual sexual contact category when the coercive tactic was presented first. Sexual experience background did not moderate the findings. The implications for the measurement of self-reported sexual aggression victimization and perpetration are discussed.