Refine
Year of publication
Document Type
- Article (26)
- Review (7)
- Postprint (6)
- Doctoral Thesis (1)
Is part of the Bibliography
- yes (40)
Keywords
- molecularly imprinted polymers (14)
- Molecularly imprinted polymers (7)
- Electropolymerization (5)
- biomimetic sensors (5)
- Biosensors (4)
- electropolymerization (4)
- Biomimetic sensors (3)
- Cytochrome P450 (3)
- direct electron transfer (3)
- Direct electron transfer (2)
- Epitope imprinting (2)
- Microperoxidase-11 (2)
- Molecularly imprinted polymer (2)
- Nanoparticles (2)
- Proteins (2)
- Redox marker (2)
- SEIRA spectroelectrochemistry (2)
- SELEX (2)
- Scopoletin (2)
- anticancer drug (2)
- aptamers (2)
- aptasensors (2)
- bioelectrocatalysis (2)
- biomimetic recognition elements (2)
- butyrylcholinesterase (2)
- catalysis (2)
- chemical sensors (2)
- electropolymerisation (2)
- enzymatic MIP synthesis (2)
- enzymatic analyte conversion (2)
- enzyme tracer (2)
- gate effect (2)
- hydrogen peroxide (2)
- in vitro selection (2)
- o-phenylenediamine (2)
- redox marker (2)
- rivastigmine (2)
- self-assembled monolayer (2)
- tamoxifen (2)
- template digestion (2)
- 4-Fluoroaniline (1)
- ATP (1)
- Aniline (1)
- Bioelectrocatalysis (1)
- Biomarker (1)
- Catalytically active MIPs (1)
- Catalytically active molecularly imprinted polymers (1)
- Catechol (1)
- Cellobiose dehydrogenase (1)
- Cytochrome c (1)
- Daptomycin (1)
- Enzymatic recycling (1)
- Esterase (1)
- Functional scaffolds (1)
- HPLC (1)
- HTHP (1)
- Hexokinase (1)
- Hybrid nanofilms (1)
- Hydrogen peroxide (1)
- Laccase (1)
- MIP (1)
- Microperoxidase (1)
- Microperoxidases (1)
- Molecularly Imprinted Polymers (1)
- Monoclonal MIPs (1)
- Multiwalled carbon nanotube (1)
- Nanohybrid (1)
- Nanostructuring (1)
- Paracetamol (1)
- Peroxidatic activity (1)
- Personalised medicine (1)
- Personalized medicine (1)
- Phenacetin (1)
- Phenolic substances (1)
- Plastibodies (1)
- Poylaniline (1)
- Protein adsorption (1)
- Protein imprinting (1)
- Pyruvate kinase (1)
- Superoxide (1)
- Surface imprinting (1)
- Third generation sensor (1)
- Transferrin (1)
- Tyrosinase (1)
- Unspecific peroxygenase (1)
- acetylcholinesterase (1)
- binding (1)
- direct electron (1)
- drug imprinting (1)
- drug sensors (1)
- electrochemical sensors (1)
- electrochemistry (1)
- electron transfer (1)
- electropolymers (1)
- electrosynthesis (1)
- enzymes (1)
- epitope imprinting (1)
- glycated peptide (1)
- gold (1)
- heme proteins (1)
- hierarchical structures (1)
- hydrochlorothiazide (1)
- irbesartan (1)
- modified electrodes (1)
- molecular modeling (1)
- molecularly imprinted electropolymers (1)
- molecularly imprinted polymer (1)
- monolayers (1)
- nanoparticles (1)
- non-specific (1)
- ophenylenediamine (1)
- p-Aminophenol (1)
- peptide imprinting (1)
- peripheral anionic site (1)
- pharmaceutical dosage forms (1)
- platinum nanoparticles (1)
- propidium (1)
- redox gating (1)
- scopoletin (1)
- transfer (1)
- tyrosinase (1)
Institute
Biosensors representing the technological counterpart of living senses have found routine application in amperometric enzyme electrodes for decentralized blood glucose measurement, interaction analysis by surface plasmon resonance in drug development, and to some extent DNA chips for expression analysis and enzyme polymorphisms. These technologies have already reached a highly advanced level and need minor improvement at most. The dream of the "100-dollar' personal genome may come true in the next few years provided that the technological hurdles of nanopore technology or of polymerase-based single molecule sequencing can be overcome. Tailor-made recognition elements for biosensors including membrane-bound enzymes and receptors will be prepared by cell-free protein synthesis. As alternatives for biological recognition elements, molecularly imprinted polymers (MIPs) have been created. They have the potential to substitute antibodies in biosensors and biochips for the measurement of low-molecular-weight substances, proteins, viruses, and living cells. They are more stable than proteins and can be produced in large amounts by chemical synthesis. Integration of nanomaterials, especially of graphene, could lead to new miniaturized biosensors with high sensitivity and ultrafast response. In the future individual therapy will include genetic profiling of isoenzymes and polymorphic forms of drug-metabolizing enzymes especially of the cytochrome P450 family. For defining the pharmacokinetics including the clearance of a given genotype enzyme electrodes will be a useful tool. For decentralized online patient control or the integration into everyday "consumables' such as drinking water, foods, hygienic articles, clothing, or for control of air conditioners in buildings and cars and swimming pools, a new generation of "autonomous' biosensors will emerge.
Molecularly imprinted polymers (MIPs) have the potential to complement antibodies in bioanalysis, are more stable under harsh conditions, and are potentially cheaper to produce. However, the affinity and especially the selectivity of MIPs are in general lower than those of their biological pendants. Enzymes are useful tools for the preparation of MIPs for both low and high-molecular weight targets: As a green alternative to the well-established methods of chemical polymerization, enzyme-initiated polymerization has been introduced and the removal of protein templates by proteases has been successfully applied. Furthermore, MIPs have been coupled with enzymes in order to enhance the analytical performance of biomimetic sensors: Enzymes have been used in MIP-sensors as tracers for the generation and amplification of the measuring signal. In addition, enzymatic pretreatment of an analyte can extend the analyte spectrum and eliminate interferences.
Molecularly imprinted polymers (MIPs) have the potential to complement antibodies in bioanalysis, are more stable under harsh conditions, and are potentially cheaper to produce. However, the affinity and especially the selectivity of MIPs are in general lower than those of their biological pendants. Enzymes are useful tools for the preparation of MIPs for both low and high-molecular weight targets: As a green alternative to the well-established methods of chemical polymerization, enzyme-initiated polymerization has been introduced and the removal of protein templates by proteases has been successfully applied. Furthermore, MIPs have been coupled with enzymes in order to enhance the analytical performance of biomimetic sensors: Enzymes have been used in MIP-sensors as tracers for the generation and amplification of the measuring signal. In addition, enzymatic pretreatment of an analyte can extend the analyte spectrum and eliminate interferences.
Enzyme electrode for aromatic compounds exploiting the catalytic activities of microperoxidase-11
(2011)
Microperoxidase-11 (MR-11) which has been immobilised in a matrix of chitosan-embedded gold nanoparticles on the surface of a glassy carbon electrode catalyzes the conversion of aromatic substances. This peroxide-dependent catalysis of microperoxidase has been applied in an enzyme electrode for the first time to indicate aromatic compounds such as aniline. 4-fluoroaniline, catechol and p-aminophenol. The electrode signal is generated by the cathodic reduction of the quinone or quinoneimine which is formed in the presence of both MP-II and peroxide from the substrate. The same sensor principle will be extended to aromatic drugs.
Molecularly imprinted polymers (MIPs) for the recognition of proteins are expected to possess high affinity through the establishment of multiple interactions between the polymer matrix and the large number of functional groups of the target. However, while highly affine recognition sites need building blocks rich in complementary functionalities to their target, such units are likely to generate high levels of nonspecific binding. This paradox, that nature solved by evolution for biological receptors, needs to be addressed by the implementation of new concepts in molecular imprinting of proteins. Additionally, the structural variability, large size and incompatibility with a range of monomers made the development of protein MIPs to take a slow start. While the majority of MIP preparation methods are variants of chemical polymerization, the polymerization of electroactive functional monomers emerged as a particularly advantageous approach for chemical sensing application. Electropolymerization can be performed from aqueous solutions to preserve the natural conformation of the protein templates, with high spatial resolution and electrochemical control of the polymerization process. This review compiles the latest results, identifying major trends and providing an outlook on the perspectives of electrosynthesised protein-imprinted MIPs for chemical sensing. (C) 2016 Elsevier B.V. All rights reserved.
The first molecularly imprinted polymer (MIP) for the recognition of the copper-enzyme laccase was successfully prepared by electropolymerizing scopoletin in the presence of alkaline-inactivated enzyme. Laccase-MIP and the control polymer without laccase (nonimprinted polymer, NIP) were characterized by voltammetry using the redox marker ferricyanide. After electropolymerization, the signals for ferricyanide for both the MIP and the NIP were almost completely suppressed and increased after removal of the target from the polymer layer. Rebinding of both inactivated and active laccase decreased the ferricyanide peak currents to almost equal extent. The relative decrease of signal suppression approached saturation above 10 nM. Furthermore, the surface activity of rebound laccase toward the oxidation of catechol was investigated. The surface activity approached saturation above 10 nM, a value close to the value of the measurements with ferricyanide. Interaction of NIP with laccase brought about a six times smaller signal of catechol oxidation.
Molecularly imprinted polymer (MP) nanofilrns for transferrin (Trf) have been synthesized on gold surfaces by electro-polymerizing the functional monomer scopoletin in the presence of the protein target or around pre-adsorbed Trf. As determined by atomic force microscopy (AFM) the film thickness was comparable with the molecular dimension of the target. The target (re)binding properties of the electro-synthesized MIP films was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV) through the target-binding induced permeability changes of the MIP nanofilms to the ferricyanide redox marker, as well as by surface plasmon resonance (SPR) and surface enhanced infrared absorption spectroscopy (SEIRAS) of the immobilized protein molecules. For Trf a linear concentration dependence in the lower micromolar range and an imprinting factor of similar to 5 was obtained by SWV and SPR. Furthermore, non-target proteins including the iron-free apo-Trf were discriminated by pronounced size and shape specificity. Whilst it is generally assumed that the rebinding of the target or of cross-reacting proteins exclusively takes place at the polymer here we considered also the interaction of the protein molecules with the underlying gold transducers. We demonstrate by SWV that adsorption of proteins suppresses the signal of the redox marker even at the bare gold surface and by SEIRAS that the treatment of the MIP with proteinase K or NaOH only partially removes the target protein. Therefore, we conclude that when interpreting binding of proteins to directly MIP-covered gold electrodes the interactions between the protein and the gold surface should also be considered.
In order to replace bio-macromolecules by stable synthetic materials in separation techniques and bioanalysis biomimetic receptors and catalysts have been developed: Functional monomers are polymerized together with the target analyte and after template removal cavities are formed in the "molecularly imprinted polymer" (MIP) which resemble the active sites of antibodies and enzymes. Starting almost 80 years ago, around 1,100 papers on MIPs were published in 2016. Electropolymerization allows to deposit MIPs directly on voltammetric electrodes or chips for quartz crystal microbalance (QCM) and surface plasmon resonance (SPR). For the readout of MIPs for drugs amperometry, differential pulse voltammetry (DPV) and impedance spectroscopy (EIS) offer higher sensitivity as compared with QCM or SPR. Application of simple electrochemical devices allows both the reproducible preparation of MIP sensors, but also the sensitive signal generation. Electrochemical MIP-sensors for the whole arsenal of drugs, e.g. the most frequently used analgesics, antibiotics and anticancer drugs have been presented in literature and tested under laboratory conditions. These biomimetic sensors typically have measuring ranges covering the lower nano-up to millimolar concentration range and they are stable under extreme pH and in organic solvents like nonaqueous extracts.
Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range.
Molecularly imprinted polymers (MIPs) mimic the binding sites of antibodies by substituting the amino acid-scaffold of proteins by synthetic polymers. In this work, the first MIP for the recognition of the diagnostically relevant enzyme butyrylcholinesterase (BuChE) is presented. The MIP was prepared using electropolymerization of the functional monomer o-phenylenediamine and was deposited as a thin film on a glassy carbon electrode by oxidative potentiodynamic polymerization. Rebinding and removal of the template were detected by cyclic voltammetry using ferricyanide as a redox marker. Furthermore, the enzymatic activity of BuChE rebound to the MIP was measured via the anodic oxidation of thiocholine, the reaction product of butyrylthiocholine. The response was linear between 50 pM and 2 nM concentrations of BuChE with a detection limit of 14.7 pM. In addition to the high sensitivity for BuChE, the sensor responded towards pseudo-irreversible inhibitors in the lower mM range.