Filtern
Volltext vorhanden
- nein (2)
Erscheinungsjahr
- 2004 (2)
Dokumenttyp
Gehört zur Bibliographie
- ja (2)
Institut
- Institut für Biochemie und Biologie (2) (entfernen)
Partikelverstärkte Oberflächenplasmonresonanz für die Quantifizierung von Matrix Metalloproteinase-2
(2004)
Detection of subicomolar concentrations of human matrix metalloproteinase-2 by an optical biosensor
(2004)
We describe in this paper the development of a one-step sandwich assay for the highly sensitive and fast detection of human matrix metalloproteinase (MMP)-2 (EC 3.4.24.24), using surface plasmon resonance (SPR). For the assay, two ligands were selected: monoclonal anti-MMP-2 antibody Ab-2 and the tissue inhibitor of metalloproteinases (TIMP)-2. They were chosen on the basis of (1) their affinities to MMP-2, (2) the efficiency of immobilization to the sensor chip, (3) the efficiency of adsorption to colloidal gold, and (4) the stability of these protein-coated gold particles. The assay included mixing of MMP-2 with antibody Ab-2 adsorbed to colloidal gold with a diameter of about 20 rim and injection into the flowcell of the SPR instrument containing immobilized TIMP-2. By using colloidal gold particles an amplification factor of 114 and a detection limit of 0.5 pM for MMP-2 were obtained. The precision of the assay was high even at low analyte concentrations, the standard deviation being 8.3% for five determinations of 1 pM MMP- 2. No significant binding was observed with the structurally related MMP-9. The assay is far more sensitive and faster than commonly used methods for MMP-2 detection. As TIMP-bound MMP-2 is not detected by this method, the assay can be applied for measuring free MMP-2, reflecting the imbalance of free and inhibitor-bound enzyme in various pathological situations. (C) 2004 Elsevier Inc. All rights reserved