• Treffer 10 von 181
Zurück zur Trefferliste

Feasibility of open low-field MRI measurements in adolescent athletes with spondylolisthesis

  • PURPOSE: To determine the feasibility of upright compared to supine MRI measurements to determine characteristics of the lumbar spine in AA with spondylolisthesis. METHODS: Ten AA (n=10; m/f: 4/6; 14.5±1.7y; 163±7cm; 52±8kg) from various sports, diagnosed with spondylolisthesis grade I-II Meyerding confirmed by x-ray in standing lateral view, were included. Open low-field MRI images (0.25 Tesla) in upright (82°) and supine (0°) position were evaluated by two observers. Medical imaging software was used to measure the anterior translation (AT, mm), lumbosacral joint angle (LSJA, °) and lordosis angle (LA, °). Reliability was analyzed by the intra-rater correlation coefficient (ICC) and standard error of measurements (SEM). RESULTS: Due to motion artifacts during upright position, measures of three participants had to be excluded. Between observers, AT ranged from 4.2±2.7mm to 5.5±1.9mm (ICC=0.94, SEM=0.6mm) in upright and from 4.9±2.4mm to 5.9±3.0mm (ICC=0.89, SEM=0.9mm) in supine position. LSJA varied from 5.1±2.2° to 7.3±1.5°PURPOSE: To determine the feasibility of upright compared to supine MRI measurements to determine characteristics of the lumbar spine in AA with spondylolisthesis. METHODS: Ten AA (n=10; m/f: 4/6; 14.5±1.7y; 163±7cm; 52±8kg) from various sports, diagnosed with spondylolisthesis grade I-II Meyerding confirmed by x-ray in standing lateral view, were included. Open low-field MRI images (0.25 Tesla) in upright (82°) and supine (0°) position were evaluated by two observers. Medical imaging software was used to measure the anterior translation (AT, mm), lumbosacral joint angle (LSJA, °) and lordosis angle (LA, °). Reliability was analyzed by the intra-rater correlation coefficient (ICC) and standard error of measurements (SEM). RESULTS: Due to motion artifacts during upright position, measures of three participants had to be excluded. Between observers, AT ranged from 4.2±2.7mm to 5.5±1.9mm (ICC=0.94, SEM=0.6mm) in upright and from 4.9±2.4mm to 5.9±3.0mm (ICC=0.89, SEM=0.9mm) in supine position. LSJA varied from 5.1±2.2° to 7.3±1.5° (ICC=0.54, SEM=1.5°) in upright and from 9.8±2.5° to 10±2.4° (ICC=0.73, SEM=1.1°) in supine position. LA differed from 58.8±14.6° to 61.9±6° (ICC=0.94, SEM=1.19°) in upright and from 51.9±11.7° to 52.6±11.1° (ICC=0.98, SEM=1.59°) in supine position. CONCLUSIONS: Determination of AT and LA showed good to excellent reliability in both, upright and supine position. In contrast, reliability of LSJA had only moderate to good correlation between observers and should therefore be interpreted with caution. However, motion artifacts should be taken into consideration during upright imaging procedures.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Theresa Anna Joost, Pia Brecht, Frank MayerORCiDGND, Michael CasselORCiDGND
DOI:https://doi.org/10.1249/01.mss.0000683832.74059.9d
ISSN:0195-9131
ISSN:1530-0315
Titel des übergeordneten Werks (Englisch):Medicine and science in sports and exercise : official journal of the American College of Sports Medicine
Verlag:Lippincott Williams & Wilkins
Verlagsort:Philadelphia
Publikationstyp:Sonstiges
Sprache:Englisch
Datum der Erstveröffentlichung:24.12.2020
Erscheinungsjahr:2020
Datum der Freischaltung:03.02.2023
Band:52
Ausgabe:17
Seitenanzahl:1
Erste Seite:790
Letzte Seite:790
Organisationseinheiten:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Sport- und Gesundheitswissenschaften
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Peer Review:Referiert
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.