Repeated measurements of Adaptive Force
- The Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisomax) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisomax, and AFmax (maximal torque of one AF measurement) were evaluated regardingThe Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisomax) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisomax, and AFmax (maximal torque of one AF measurement) were evaluated regarding different considerations and statistical tests. AFmax and AFisomax declined in the course of 30 trials [slope regression (mean ± standard deviation): AFmax = −0.323 ± 0.263; AFisomax = −0.45 ± 0.45]. The decline from start to end amounted to −12.8% ± 8.3% (p < 0.001) for AFmax and −25.41% ± 26.40% (p < 0.001) for AFisomax. AF parameters declined more in strength vs. endurance athletes. Thereby, strength athletes showed a rather stable decline for AFmax and a plateau formation for AFisomax after 15 trials. In contrast, endurance athletes reduced their AFmax, especially after the first five trials, and remained on a rather similar level for AFisomax. The maximum of AFisomax of all 30 trials amounted 67.67% ± 13.60% of MVIC (p < 0.001, n = 12), supporting the hypothesis of two types of isometric muscle action (holding vs. pushing). The findings provided the first data on the behavior of torque parameters after repeated isometric–eccentric actions and revealed further insights into neuromuscular control strategies. Additionally, they highlight the importance of investigating AF parameters in athletes based on the different behaviors compared to MVIC. This is assumed to be especially relevant regarding injury mechanisms.…
Verfasserangaben: | Laura SchaeferORCiDGND, Friederike Carnarius, Silas DechORCiDGND, Frank BittmannORCiDGND |
---|---|
URN: | urn:nbn:de:kobv:517-opus4-588030 |
DOI: | https://doi.org/10.25932/publishup-58803 |
ISSN: | 1866-8364 |
Titel des übergeordneten Werks (Deutsch): | Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe |
Untertitel (Englisch): | Maximal holding capacity differs from other maximal strength parameters and preliminary characteristics for non-professional strength vs. endurance athletes |
Schriftenreihe (Bandnummer): | Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe (831) |
Publikationstyp: | Postprint |
Sprache: | Englisch |
Datum der Erstveröffentlichung: | 22.02.2023 |
Erscheinungsjahr: | 2023 |
Veröffentlichende Institution: | Universität Potsdam |
Datum der Freischaltung: | 24.04.2023 |
Freies Schlagwort / Tag: | Adaptive Force; holding (HIMA) and pushing (PIMA) isometric muscle action; holding capacity; injury mechanisms; maximal isometric Adaptive Force; neuromuscular control; repeated adaptive isometric–eccentric muscle action; strength vs. endurance athletes |
Ausgabe: | 831 |
Seitenanzahl: | 19 |
Quelle: | Frontiers in Physiology 14 (2023); DOI: https://doi.org/10.3389/fphys.2023.1020954 |
Organisationseinheiten: | Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Sport- und Gesundheitswissenschaften |
DDC-Klassifikation: | 6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit |
Peer Review: | Referiert |
Publikationsweg: | Open Access / Green Open-Access |
Lizenz (Deutsch): | ![]() |
Externe Anmerkung: | Bibliographieeintrag der Originalveröffentlichung |