• Treffer 27 von 35
Zurück zur Trefferliste

Repeated measurements of Adaptive Force

  • The Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisomax) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisomax, and AFmax (maximal torque of one AF measurement) were evaluated regardingThe Adaptive Force (AF) reflects the neuromuscular capacity to adapt to external loads during holding muscle actions and is similar to motions in real life and sports. The maximal isometric AF (AFisomax) was considered to be the most relevant parameter and was assumed to have major importance regarding injury mechanisms and the development of musculoskeletal pain. The aim of this study was to investigate the behavior of different torque parameters over the course of 30 repeated maximal AF trials. In addition, maximal holding vs. maximal pushing isometric muscle actions were compared. A side consideration was the behavior of torques in the course of repeated AF actions when comparing strength and endurance athletes. The elbow flexors of n = 12 males (six strength/six endurance athletes, non-professionals) were measured 30 times (120 s rest) using a pneumatic device. Maximal voluntary isometric contraction (MVIC) was measured pre and post. MVIC, AFisomax, and AFmax (maximal torque of one AF measurement) were evaluated regarding different considerations and statistical tests. AFmax and AFisomax declined in the course of 30 trials [slope regression (mean ± standard deviation): AFmax = −0.323 ± 0.263; AFisomax = −0.45 ± 0.45]. The decline from start to end amounted to −12.8% ± 8.3% (p < 0.001) for AFmax and −25.41% ± 26.40% (p < 0.001) for AFisomax. AF parameters declined more in strength vs. endurance athletes. Thereby, strength athletes showed a rather stable decline for AFmax and a plateau formation for AFisomax after 15 trials. In contrast, endurance athletes reduced their AFmax, especially after the first five trials, and remained on a rather similar level for AFisomax. The maximum of AFisomax of all 30 trials amounted 67.67% ± 13.60% of MVIC (p < 0.001, n = 12), supporting the hypothesis of two types of isometric muscle action (holding vs. pushing). The findings provided the first data on the behavior of torque parameters after repeated isometric–eccentric actions and revealed further insights into neuromuscular control strategies. Additionally, they highlight the importance of investigating AF parameters in athletes based on the different behaviors compared to MVIC. This is assumed to be especially relevant regarding injury mechanisms.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • zhr831.pdfeng
    (1954KB)

    SHA-512:f070bde4691ea87d595e7963299ded793ff297608920c5fa7ea50e25ed65e0af14914d4f42d9990d45e5ecebb96fbefec71f658a48873843c75b35fc7d7582ee

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Laura SchaeferORCiDGND, Friederike Carnarius, Silas DechORCiDGND, Frank BittmannORCiDGND
URN:urn:nbn:de:kobv:517-opus4-588030
DOI:https://doi.org/10.25932/publishup-58803
ISSN:1866-8364
Titel des übergeordneten Werks (Deutsch):Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe
Untertitel (Englisch):Maximal holding capacity differs from other maximal strength parameters and preliminary characteristics for non-professional strength vs. endurance athletes
Schriftenreihe (Bandnummer):Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe (831)
Publikationstyp:Postprint
Sprache:Englisch
Datum der Erstveröffentlichung:22.02.2023
Erscheinungsjahr:2023
Veröffentlichende Institution:Universität Potsdam
Datum der Freischaltung:24.04.2023
Freies Schlagwort / Tag:Adaptive Force; holding (HIMA) and pushing (PIMA) isometric muscle action; holding capacity; injury mechanisms; maximal isometric Adaptive Force; neuromuscular control; repeated adaptive isometric–eccentric muscle action; strength vs. endurance athletes
Ausgabe:831
Seitenanzahl:19
Quelle:Frontiers in Physiology 14 (2023); DOI: https://doi.org/10.3389/fphys.2023.1020954
Organisationseinheiten:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Sport- und Gesundheitswissenschaften
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Peer Review:Referiert
Publikationsweg:Open Access / Green Open-Access
Lizenz (Deutsch):License LogoCC-BY - Namensnennung 4.0 International
Externe Anmerkung:Bibliographieeintrag der Originalveröffentlichung
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.