• Treffer 3 von 8
Zurück zur Trefferliste

Validation of a user-friendly and rapid method for quantifying iodine content of salt

  • Background. Despite considerable progress made in the past decade through salt iodization programs, over 2 billion people worldwide still have inadequate iodine intake, with devastating consequences for brain development and intellectual capacity. To optimize these programs with regard to salt iodine content, careful monitoring of salt iodine content is essential, but few methods are available to quantitatively measure iodine concentration in a simple, fast, and safe way. Objective. We have validated a newly developed device that quantitatively measures the content of potassium iodate in salt in a simple, safe, and rapid way. Methods. The linearity, determination and detection limit, and inter- and intra-assay variability of this colorimetric method were assessed and the method was compared with iodometric titration, using salt samples from several countries. Results. Linearity of analysis ranged from 5 to 75 mg/kg iodine, with I mg/kg being the determination limit; the intra- and interassay imprecision was 0.9%, 0.5%, and 0.7% andBackground. Despite considerable progress made in the past decade through salt iodization programs, over 2 billion people worldwide still have inadequate iodine intake, with devastating consequences for brain development and intellectual capacity. To optimize these programs with regard to salt iodine content, careful monitoring of salt iodine content is essential, but few methods are available to quantitatively measure iodine concentration in a simple, fast, and safe way. Objective. We have validated a newly developed device that quantitatively measures the content of potassium iodate in salt in a simple, safe, and rapid way. Methods. The linearity, determination and detection limit, and inter- and intra-assay variability of this colorimetric method were assessed and the method was compared with iodometric titration, using salt samples from several countries. Results. Linearity of analysis ranged from 5 to 75 mg/kg iodine, with I mg/kg being the determination limit; the intra- and interassay imprecision was 0.9%, 0.5%, and 0.7% and 1.5%, 1.7%, and 2.5% for salt samples with iodine contents of 17, 30, and 55 mg/kg, respectively; the interoperator imprecision for the same samples was 1.2%, 4.9%, and 4.7%, respectively. Comparison with the iodometric method showed high agreement between the methods (R-2 = 0.978; limits of agreement, -10.5 to 10.0 mg/kg). Conclusions. The device offers a field- and user-friendly solution to quantifying potassium iodate salt content reliably. For countries that use potassium iodide in salt iodization programs, further validation is required.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Fabian Rohner, Greg S. Garrett, Arnaud Laillou, Simone K. Frey, Ralf Mothes, Florian J. SchweigertORCiDGND, Lorenzo Locatelli-Rossi
ISSN:0379-5721
Titel des übergeordneten Werks (Englisch):Food and nutrition bulletin
Verlag:International Nutrition Foundation
Verlagsort:Boston
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2012
Erscheinungsjahr:2012
Datum der Freischaltung:26.03.2017
Freies Schlagwort / Tag:Iodization; iodine; monitoring; potassium iodate; quality control; rapid test kit; regulatory monitoring; salt
Band:33
Ausgabe:4
Seitenanzahl:6
Erste Seite:S330
Letzte Seite:S335
Fördernde Institution:Global Alliance for Improved Nutrition (GAIN) through Bill and Melinda Gates Foundation; UK Department for International Development (DFID)
Organisationseinheiten:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Ernährungswissenschaft
Peer Review:Referiert
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.