• Treffer 14 von 16
Zurück zur Trefferliste

Validation of two accelerometers to determine mechanical loading of physical activities in children

  • The purpose of this study was to assess the validity of accelerometers using force plates (i.e., ground reaction force (GRF)) during the performance of different tasks of daily physical activity in children. Thirteen children (10.1 (range 5.4-15.7)years, 3 girls) wore two accelerometers (ActiGraph GT3X+ (ACT), GENEA (GEN)) at the hip that provide raw acceleration signals at 100Hz. Participants completed different tasks (walking, jogging, running, landings from boxes of different height, rope skipping, dancing) on a force plate. GRF was collected for one step per trial (10 trials) for ambulatory movements and for all landings (10 trials), rope skips and dance procedures. Accelerometer outputs as peak loading (g) per activity were averaged. ANOVA, correlation analyses and Bland-Altman plots were computed to determine validity of accelerometers using GRF. There was a main effect of task with increasing acceleration values in tasks with increasing locomotion speed and landing height (P<0.001). Data from ACT and GEN correlated with GRFThe purpose of this study was to assess the validity of accelerometers using force plates (i.e., ground reaction force (GRF)) during the performance of different tasks of daily physical activity in children. Thirteen children (10.1 (range 5.4-15.7)years, 3 girls) wore two accelerometers (ActiGraph GT3X+ (ACT), GENEA (GEN)) at the hip that provide raw acceleration signals at 100Hz. Participants completed different tasks (walking, jogging, running, landings from boxes of different height, rope skipping, dancing) on a force plate. GRF was collected for one step per trial (10 trials) for ambulatory movements and for all landings (10 trials), rope skips and dance procedures. Accelerometer outputs as peak loading (g) per activity were averaged. ANOVA, correlation analyses and Bland-Altman plots were computed to determine validity of accelerometers using GRF. There was a main effect of task with increasing acceleration values in tasks with increasing locomotion speed and landing height (P<0.001). Data from ACT and GEN correlated with GRF (r=0.90 and 0.89, respectively) and between each other (r=0.98), but both accelerometers consistently overestimated GRF. The new generation of accelerometer models that allow raw signal detection are reasonably accurate to measure impact loading of bone in children, although they systematically overestimate GRF.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Ursina Meyer, Dominique Ernst, Silvia Schott, Claudia Riera, Jan Hattendorf, Jacqueline Romkes, Urs GranacherORCiDGND, Beat Göpfert, Susi Kriemler
DOI:https://doi.org/10.1080/02640414.2015.1004638
ISSN:0264-0414
ISSN:1466-447X
Pubmed ID:https://pubmed.ncbi.nlm.nih.gov/25620031
Titel des übergeordneten Werks (Englisch):Journal of sports sciences
Verlag:Routledge, Taylor & Francis Group
Verlagsort:Abingdon
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2015
Erscheinungsjahr:2015
Datum der Freischaltung:27.03.2017
Freies Schlagwort / Tag:bone; children; ground reaction force; impact loading; physical activity
Band:33
Ausgabe:16
Seitenanzahl:8
Erste Seite:1702
Letzte Seite:1709
Organisationseinheiten:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften
Peer Review:Referiert
Name der Einrichtung zum Zeitpunkt der Publikation:Humanwissenschaftliche Fakultät / Exzellenzbereich Kognitionswissenschaften
Verstanden ✔