Coherence experiments at the white-beam beamline of BESSYI
- The third-generation X-ray source BESSYII (Berlin, Germany) provides coherent X-ray radiation which can be used for static and dynamic speckle analysis. Recently we have demonstrated that one can perform experiments with coherent white radiation provided by a bending magnet (5 < E < 20 keV). In this paper we show that the diffraction figure of the initial pinhole must be considered for the interpretation of coherent experiments. The reflectivity spectrum of a sample results from the Fresnel diffraction of the incident pinhole deformed by the static speckle features of the sample surface. For dynamical experiments all speckle like features alter with time whereas the pure Fresnel fringes remain constant. (c) 2007 Published by Elsevier B.V.
Verfasserangaben: | Tobias Panzner, Gudrun Gleber, Tushar Sant, Wolfram LeitenbergerGND, Ullrich Pietsch |
---|---|
URL: | http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B6TW0-4N08M4P-1- F&_cdi=5548&_user=1584062&_orig=search&_coverDate=05%2F23%2F2007&_sk=994849985&view=c&wchp=dGLbVzW- zSkWA&md5=3a09375f874dccd9b382488e9d0 |
DOI: | https://doi.org/10.1016/j.tsf.2006.12.002 |
Publikationstyp: | Wissenschaftlicher Artikel |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2007 |
Erscheinungsjahr: | 2007 |
Datum der Freischaltung: | 25.03.2017 |
Quelle: | Thin Solid Films. - 515 (2007), 14, S. 5563 - 5567 |
Organisationseinheiten: | Mathematisch-Naturwissenschaftliche Fakultät / Institut für Physik und Astronomie |
Name der Einrichtung zum Zeitpunkt der Publikation: | Mathematisch-Naturwissenschaftliche Fakultät / Institut für Physik |