• Treffer 1 von 0
Zurück zur Trefferliste

Plantar pressure trigger for reliable nerve stimulus application during dynamic H-reflex measurements

  • In dynamic H-reflex measurements, the standardisation of the nerve stimulation to the gait cycle is crucial to avoid misinterpretation due to altered pre-synaptic inhibition. In this pilot study, a plantar pressure sole was used to trigger the stimulation of the tibialis nerve with respect to the gait cycle. Consequently, the intersession reliability of the soleus muscle H-reflex during treadmill walking was investigated. Seven young participants performed walking trials on a treadmill at 5 km/h. The stimulating electrode was placed on the tibial nerve in the popliteal fossa. An EMG was recorded from the soleus muscle. To synchronize the stimulus to the gait cycle, initial heel strike was detected with a plantar pressure sole. Maximum H-reflex amplitude and M-wave amplitude were obtained and the Hmax/Mmax ratio was calculated. Data reveals excellent reliability, ICC = 0.89. Test-retest variability was 13.0% (+/- 11.8). The Bland-Altman analysis showed a systematic error of 2.4%. The plantar pressure sole was capable of triggeringIn dynamic H-reflex measurements, the standardisation of the nerve stimulation to the gait cycle is crucial to avoid misinterpretation due to altered pre-synaptic inhibition. In this pilot study, a plantar pressure sole was used to trigger the stimulation of the tibialis nerve with respect to the gait cycle. Consequently, the intersession reliability of the soleus muscle H-reflex during treadmill walking was investigated. Seven young participants performed walking trials on a treadmill at 5 km/h. The stimulating electrode was placed on the tibial nerve in the popliteal fossa. An EMG was recorded from the soleus muscle. To synchronize the stimulus to the gait cycle, initial heel strike was detected with a plantar pressure sole. Maximum H-reflex amplitude and M-wave amplitude were obtained and the Hmax/Mmax ratio was calculated. Data reveals excellent reliability, ICC = 0.89. Test-retest variability was 13.0% (+/- 11.8). The Bland-Altman analysis showed a systematic error of 2.4%. The plantar pressure sole was capable of triggering the stimulation of the tibialis nerve in a reliable way and offers a simple technique for the evaluation of reflex activity during walking.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Niklas König, Antje ReschkeORCiDGND, Martin Wolter, Steffen MüllerGND, Frank MayerORCiDGND, Heiner BaurORCiDGND
DOI:https://doi.org/10.1016/j.gaitpost.2012.09.021
ISSN:0966-6362
Titel des übergeordneten Werks (Englisch):Gait & posture
Verlag:Elsevier
Verlagsort:Clare
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2013
Erscheinungsjahr:2013
Datum der Freischaltung:26.03.2017
Freies Schlagwort / Tag:Monosynaptic reflexes; Reflex reproducibility; Treadmill walking
Band:37
Ausgabe:4
Seitenanzahl:3
Erste Seite:637
Letzte Seite:639
Fördernde Institution:German Federal Ministry of Economics and Technology (BMWi Bundesministerium fur Wirtschaft und Technologie), Berlin, Germany [KA0121102KF7]
Organisationseinheiten:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Sport- und Gesundheitswissenschaften
Peer Review:Referiert
Name der Einrichtung zum Zeitpunkt der Publikation:Humanwissenschaftliche Fakultät / Institut für Sportmedizin und Prävention
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.