• Treffer 2 von 8
Zurück zur Trefferliste

The Double Quasar HE 1104-1805 : a case study for time delay determination with poorly sampled lightcurves

  • We present a new determination of the time delay of the gravitational lens system HE 1104-1805 (``Double Hamburger'') based on a previously unpublished dataset. We argue that the previously published value of Delta tA-B=0.73 years was affected by a bias of the employed method. We determine a new value of Delta tA-B=0.85+/-0.05 years (2sigma confidence level), using six different techniques based on non interpolation methods in the time domain. The result demonstrates that even in the case of poorly sampled lightcurves, useful information can be obtained with regard to the time delay. The error estimates were calculated through Monte Carlo simulations. With two already existing models for the lens and using its recently determined redshift, we infer a range of values of the Hubble parameter: H0=48+/-4 km s-1 Mpc-1 (2sigma ) for a singular isothermal ellipsoid (SIE) and H0=62+/-4 km s-1 Mpc-1 (2sigma ) for a constant mass-to-light ratio plus shear model (M/L+gamma ). The possibly much larger errors due to systematic uncertainties inWe present a new determination of the time delay of the gravitational lens system HE 1104-1805 (``Double Hamburger'') based on a previously unpublished dataset. We argue that the previously published value of Delta tA-B=0.73 years was affected by a bias of the employed method. We determine a new value of Delta tA-B=0.85+/-0.05 years (2sigma confidence level), using six different techniques based on non interpolation methods in the time domain. The result demonstrates that even in the case of poorly sampled lightcurves, useful information can be obtained with regard to the time delay. The error estimates were calculated through Monte Carlo simulations. With two already existing models for the lens and using its recently determined redshift, we infer a range of values of the Hubble parameter: H0=48+/-4 km s-1 Mpc-1 (2sigma ) for a singular isothermal ellipsoid (SIE) and H0=62+/-4 km s-1 Mpc-1 (2sigma ) for a constant mass-to-light ratio plus shear model (M/L+gamma ). The possibly much larger errors due to systematic uncertainties in modeling the lens potential are not included in this error estimate.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Rodrigo Gil-Merino, Lutz WisotzkiORCiDGND, Joachim Wambsganß
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2002
Erscheinungsjahr:2002
Datum der Freischaltung:24.03.2017
Quelle:Astronomy and Astrophysics. - 381 (2002), 2, S. 428 - 439
Organisationseinheiten:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Physik und Astronomie
Name der Einrichtung zum Zeitpunkt der Publikation:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Physik
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.