Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 3 von 5
Zurück zur Trefferliste

Test-retest reliability of the olfactory detection threshold test of the Sniffin' Sticks

  • The aim of the present study was to investigate the test-retest reliability of the olfactory detection threshold subtest of the Sniffin" Sticks test battery, if administered repeatedly on 4 time points. The detection threshold test was repeatedly conducted in 64 healthy subjects. On the first testing session, the threshold test was accomplished 3 times (T(1) = 0 min, T(2) = 35 min, and T(3) = 105 min), representing a short-term testing. A fourth threshold test was conducted on a second testing session (T(4) = 35.1 days after the first testing session), representing a long-term testing. The average scores for olfactory detection threshold for n-butanol did not differ significantly across the 4 points of time. The test-retest reliability (Pearson"s r) between the 4 time points of threshold testing were in a range of 0.43-0.85 (P < 0.01). These results support the notion that the olfactory detection threshold test is a highly reliable method for repeated olfactory testing, even if the test is repeated more than once per day and over aThe aim of the present study was to investigate the test-retest reliability of the olfactory detection threshold subtest of the Sniffin" Sticks test battery, if administered repeatedly on 4 time points. The detection threshold test was repeatedly conducted in 64 healthy subjects. On the first testing session, the threshold test was accomplished 3 times (T(1) = 0 min, T(2) = 35 min, and T(3) = 105 min), representing a short-term testing. A fourth threshold test was conducted on a second testing session (T(4) = 35.1 days after the first testing session), representing a long-term testing. The average scores for olfactory detection threshold for n-butanol did not differ significantly across the 4 points of time. The test-retest reliability (Pearson"s r) between the 4 time points of threshold testing were in a range of 0.43-0.85 (P < 0.01). These results support the notion that the olfactory detection threshold test is a highly reliable method for repeated olfactory testing, even if the test is repeated more than once per day and over a long-term period. It is concluded that the olfactory detection threshold test of the Sniffin" Sticks is suitable for repeated testing during experimental or clinical studies.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Jessica Albrecht, Andrea Anzinger, Rainer Kopietz, Veronika Schöpf, Anna Maria Kleemann, Olga PollatosGND, Martin Wiesmann
URL:http://chemse.oxfordjournals.org/
ISSN:0379-864X
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2008
Erscheinungsjahr:2008
Datum der Freischaltung:25.03.2017
Quelle:Chemical senses. - ISSN 0379-864X. - 33 (2008), 5, S. 461 - 467
Organisationseinheiten:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Psychologie
Peer Review:Referiert
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.