Blood lactate concentrations are mildly affected by mobile gas exchange measurements

  • We sought to investigate the effects of wearing a mobile respiratory gas analysis system during a treadmill test on blood lactate (bLa) concentrations and commonly applied bLa thresholds. A total of 16 recreational athletes (31 +/- 3 years, V0205: 58 6 ml min(-1)-kg(-1)) performed one multistage treadmill test with and one without gas exchange measurements (GEM and noGEM). The whole bLa curve, the lactate threshold (LT), the individual anaerobic thresholds according to Stegmann(IAT(sr)) and Dickhuth (IAT(Di)), and a fixed bLa concentration of 4 mmob.l(-1) (OBLA) were evaluated. The bLa curve was shifted slightly leftward in GEM compared to noGEM (P<0.05), whereas the heart rate response was not different between conditions (P= 0.89). There was no difference between GEM and noGEM for LT (2.61 +/- 0.34 vs. 2.64 +/- 0.39 m(-1) s(-1) P=0.49) and IAT(st) (3.47 +/- 0.42 vs. 3.55 +/- 0.47m-s(-1), P=0.12). However, IATD(Di) (3.57 +/- 0.39 vs. 3.66 +/- 0.44m-s(-1), P<0.01) and OBLA (3.85 +/- 0.46 vs. 3.96 +/- 0.47m-s-1, P<0.01) occurred atWe sought to investigate the effects of wearing a mobile respiratory gas analysis system during a treadmill test on blood lactate (bLa) concentrations and commonly applied bLa thresholds. A total of 16 recreational athletes (31 +/- 3 years, V0205: 58 6 ml min(-1)-kg(-1)) performed one multistage treadmill test with and one without gas exchange measurements (GEM and noGEM). The whole bLa curve, the lactate threshold (LT), the individual anaerobic thresholds according to Stegmann(IAT(sr)) and Dickhuth (IAT(Di)), and a fixed bLa concentration of 4 mmob.l(-1) (OBLA) were evaluated. The bLa curve was shifted slightly leftward in GEM compared to noGEM (P<0.05), whereas the heart rate response was not different between conditions (P= 0.89). There was no difference between GEM and noGEM for LT (2.61 +/- 0.34 vs. 2.64 +/- 0.39 m(-1) s(-1) P=0.49) and IAT(st) (3.47 +/- 0.42 vs. 3.55 +/- 0.47m-s(-1), P=0.12). However, IATD(Di) (3.57 +/- 0.39 vs. 3.66 +/- 0.44m-s(-1), P<0.01) and OBLA (3.85 +/- 0.46 vs. 3.96 +/- 0.47m-s-1, P<0.01) occurred at slower running velocities in GEM. The bLa response to treadmill tests is mildly affected by wearing a mobile gas analysis system. This also applies to bLa thresholds located at higher exercise intensities. While the magnitude of the effects is of little importance for recreational athletes, it might be relevant for elite athletes and scientific studies.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Verfasserangaben:Friederike Scharhag-RosenbergerORCiDGND, Monique WochatzORCiDGND, Christoph Otto, Michael CasselORCiDGND, Frank MayerORCiDGND, Jürgen Scharhag
DOI:https://doi.org/10.1055/s-0033-1354386
ISSN:0172-4622
ISSN:1439-3964
Pubmed ID:https://pubmed.ncbi.nlm.nih.gov/24258472
Titel des übergeordneten Werks (Englisch):International journal of sports medicine
Verlag:Thieme
Verlagsort:Stuttgart
Publikationstyp:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Erstveröffentlichung:2014
Erscheinungsjahr:2014
Datum der Freischaltung:27.03.2017
Freies Schlagwort / Tag:VO2mdx; cardiopulmonary exercise testing; lactate threshold; metabolic device; performance diagnostics
Band:35
Ausgabe:7
Seitenanzahl:5
Erste Seite:590
Letzte Seite:594
Organisationseinheiten:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Sport- und Gesundheitswissenschaften
Peer Review:Referiert
Name der Einrichtung zum Zeitpunkt der Publikation:Humanwissenschaftliche Fakultät / Institut für Sportmedizin und Prävention
Verstanden ✔
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.