Refine
Year of publication
Document Type
- Article (82)
- Postprint (17)
- Conference Proceeding (10)
- Doctoral Thesis (2)
- Habilitation Thesis (1)
- Preprint (1)
- Review (1)
Is part of the Bibliography
- yes (114)
Keywords
- EMG (6)
- young athletes (6)
- Children (5)
- back pain (5)
- fertilization (5)
- trunk (5)
- Biodiversity Exploratories (4)
- Biodiversity exploratories (4)
- Nitrogen (4)
- land use (4)
Institute
- Department Sport- und Gesundheitswissenschaften (49)
- Institut für Biochemie und Biologie (35)
- Strukturbereich Kognitionswissenschaften (8)
- Institut für Chemie (7)
- Humanwissenschaftliche Fakultät (4)
- Institut für Ernährungswissenschaft (4)
- Institut für Informatik und Computational Science (3)
- Mathematisch-Naturwissenschaftliche Fakultät (2)
- Department Erziehungswissenschaft (1)
- Extern (1)
Co-doping of the MOF 3∞[Zn(2-methylimidazolate-4-amide-5-imidate)] (IFP-1 = Imidazolate Framework Potsdam-1) with luminescent Eu3+ and Tb3+ ions presents an approach to utilize the porosity of the MOF for the intercalation of luminescence centers and for tuning of the chromaticity to the emission of white light of the quality of a three color emitter. Organic based fluorescence processes of the MOF backbone as well as metal based luminescence of the dopants are combined to one homogenous single source emitter while retaining the MOF's porosity. The lanthanide ions Eu3+ and Tb3+ were doped in situ into IFP-1 upon formation of the MOF by intercalation into the micropores of the growing framework without a structure directing effect. Furthermore, the color point is temperature sensitive, so that a cold white light with a higher blue content is observed at 77 K and a warmer white light at room temperature (RT) due to the reduction of the organic emission at higher temperatures. The study further illustrates the dependence of the amount of luminescent ions on porosity and sorption properties of the MOF and proves the intercalation of luminescence centers into the pore system by low-temperature site selective photoluminescence spectroscopy, SEM and EDX. It also covers an investigation of the border of homogenous uptake within the MOF pores and the formation of secondary phases of lanthanide formates on the surface of the MOF. Crossing the border from a homogenous co-doping to a two-phase composite system can be beneficially used to adjust the character and warmth of the white light. This study also describes two-color emitters of the formula Ln@IFP-1a–d (Ln: Eu, Tb) by doping with just one lanthanide Eu3+ or Tb3+.
Co-doping of the MOF 3∞[Zn(2-methylimidazolate-4-amide-5-imidate)] (IFP-1 = Imidazolate Framework Potsdam-1) with luminescent Eu3+ and Tb3+ ions presents an approach to utilize the porosity of the MOF for the intercalation of luminescence centers and for tuning of the chromaticity to the emission of white light of the quality of a three color emitter. Organic based fluorescence processes of the MOF backbone as well as metal based luminescence of the dopants are combined to one homogenous single source emitter while retaining the MOF's porosity. The lanthanide ions Eu3+ and Tb3+ were doped in situ into IFP-1 upon formation of the MOF by intercalation into the micropores of the growing framework without a structure directing effect. Furthermore, the color point is temperature sensitive, so that a cold white light with a higher blue content is observed at 77 K and a warmer white light at room temperature (RT) due to the reduction of the organic emission at higher temperatures. The study further illustrates the dependence of the amount of luminescent ions on porosity and sorption properties of the MOF and proves the intercalation of luminescence centers into the pore system by low-temperature site selective photoluminescence spectroscopy, SEM and EDX. It also covers an investigation of the border of homogenous uptake within the MOF pores and the formation of secondary phases of lanthanide formates on the surface of the MOF. Crossing the border from a homogenous co-doping to a two-phase composite system can be beneficially used to adjust the character and warmth of the white light. This study also describes two-color emitters of the formula Ln@IFP-1a–d (Ln: Eu, Tb) by doping with just one lanthanide Eu3+ or Tb3+.
Functional gait development in children is discussed controversially. Differentiated information about the roll- over process of the foot, represented by the "Center of Pressure" (COP), are still missing. The purpose of the study was the validation of the COP-path to quantify the functional gait development of children. Plantar pressure distribution was measured barefoot with an individual speed on a walkway (tartan) - in 255 children aged between 2 and 15 years. The medial and lateral area enclosed between the COP-path and the bisection of plantar angle (A(med), A(lat), Sigma: A(ml)) was calculated from plantar pressure data. Furthermore, the duration of the COP-path in the heel (COPtimeF), midfoot (COPtimeM) and forefoot (COPtimeV) was analysed. The load distribution under the medial and lateral forefoot was also calculated. The variation coefficient (VC) was calculated as a measure of interindividual variability. The medio-lateral divergency of the COP (Aml) initially decreases with advancing age (-20.2%), followed by a continuous increase (+27.2%). No changes in VC (A(med), A(lat), and A(ml)) appeared during age-related development. COPtimeM remains constant in all children over time. In contrast to COPtimeM, Cop(time)F decreases from youngest to oldest children (-31.0%), and COPtimeV increases (+41.7%). After initial descent up to 8 years of age, VC (COPtimeF, COPtimeM, COPtimeV) remains constant. The mediolateral load under the forefoot did not change. The COP-Path is able to characterise the functional gait development of children. VC values indicate high individual variability of gait pattern. In this context, age-based standard values should be critically discussed
Background: Isokinetic measurements are widely used to assess strength capacity in a clinical or research context. Nevertheless, the validity of isokinetic measures for identifying strength deficits and the evaluation of therapeutic process regarding different pathologies is yet to be established. Therefore, the purpose of this review is to evaluate the validity of isokinetic measures in a specific case: that of muscular capacity in low back pain (LBP).
Methods: A literature search (PubMed; ISI Web of Knowledge; The Cochrane Library) covering the last 10 years was performed. Relevant papers regarding isokinetic trunk strength measures in healthy and patients with low back pain (PLBP) were searched. Peak torque values [Nm] and peak torque normalized to body weight [Nm/kg BW] were extracted for healthy and PLBP. Ranked mean values across studies were calculated for the concentric peak torque at 60 degrees/s as well as the flexion/extension (F/E) ratio.
Results: 34 publications (31 flexion/extension; 3 rotation) were suitable for reporting detailed isokinetic strength measures in healthy or LBP (untrained adults, adolescents, athletes). Adolescents and athletes were different compared to normal adults in terms of absolute trunk strength values and the F/E ratio. Furthermore, isokinetic measures evaluating therapeutic process and isokinetic rehabilitation training were infrequent in literature (8 studies).
Conclusion: Isokinetic measurements are valid for measuring trunk flexion/extension strength and F/E ratio in athletes, adolescents and (untrained) adults with/without LBP. The validity of trunk rotation is questionable due to a very small number of publications whereas no reliable source regarding lateral flexion could be traced. Therefore, isokinetic dynamometry may be utilized for identifying trunk strength deficits in healthy adults and PLBP.
Assessing diversity is among the major tasks in ecology and conservation science. In ecological and conservation studies, epiphytic cryptogams are usually sampled up to accessible heights in forests. Thus, their diversity, especially of canopy specialists, likely is underestimated. If the proportion of those species differs among forest types, plot-based diversity assessments are biased and may result in misleading conservation recommendations. We sampled bryophytes and lichens in 30 forest plots of 20 m x 20 m in three German regions, considering all substrates, and including epiphytic litter fall. First, the sampling of epiphytic species was restricted to the lower 2 m of trees and shrubs. Then, on one representative tree per plot, we additionally recorded epiphytic species in the crown, using tree climbing techniques. Per tree, on average 54% of lichen and 20% of bryophyte species were overlooked if the crown was not been included. After sampling all substrates per plot, including the bark of all shrubs and trees, still 38% of the lichen and 4% of the bryophyte species were overlooked if the tree crown of the sampled tree was not included. The number of overlooked lichen species varied strongly among regions. Furthermore, the number of overlooked bryophyte and lichen species per plot was higher in European beech than in coniferous stands and increased with increasing diameter at breast height of the sampled tree. Thus, our results indicate a bias of comparative studies which might have led to misleading conservation recommendations of plot-based diversity assessments.
Ultrasound evaluation of the patellar tendon cross-sectional area and its relation to maximum force
(2012)
BACKGROUND: Reproducible measurements of tendon structural properties are a prerequisite for accurate diagnosis of tendon disorders and for determination of their mechanical properties. Despite the widely used application of Ultrasonography (US) in musculoskeletal assessment, its operator dependency and lack of standardization influences the consistency of the measurement.
OBJECTIVE: To evaluate the intra-rater reproducibility of a standardized US method assessing the structural properties of the Achilles tendon (AT).
METHODS: Sixteen asymptomatic participants were positioned prone on an isokinetic dynamometer with the knee extended and ankle at 90. flexion. US was used to assess AT-length, cross-sectional area (CSA), and AT-elongation during isometric plantarflexion contraction. The intra-rater reproducibility was assessed by ICC (2.1), Test-Retest Variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]), and Standard-Error of Measurement (SEM).
RESULTS: Measurements of AT-length demonstrated an ICC of 0.93, TRV of 4.5 +/- 3.9%, Bias +/- LoA of -2.8 +/- 25.0 mm and SEM of 6.6 mm. AT-CSA showed an ICC of 0.79, TRV of 8.7 +/- 9.6%, Bias +/- LoA of 1.7 +/- 19.4 mm(2) and SEM of 5.3 mm(2). AT-elongation revealed an ICC of 0.92, TRV of 12.9 +/- 8.9%, Bias +/- LoA of 0.3 +/- 5.7 mm and SEM of 1.5 mm.
CONCLUSIONS: The presented methodology allows a reproducible assessment of Achilles tendon structural properties when performed by a single rater.