Refine
Has Fulltext
- no (3)
Document Type
- Article (2)
- Conference Proceeding (1)
Language
- English (3)
Is part of the Bibliography
- yes (3)
Keywords
- Blood (1)
- Iodization (1)
- Milk (1)
- Point of Care Assay and Vitamin A (1)
- iodine (1)
- monitoring (1)
- potassium iodate (1)
- quality control (1)
- rapid test kit (1)
- regulatory monitoring (1)
Institute
Adipogenesis is governed by a well-documented cascade of transcription factors. However, less is known about non-transcription factors that govern early stages of adipogenesis. Here we show that cellular retinol-binding protein type I (CRBP-I), a small cytosolic binding protein for retinol and retinaldehyde, is specifically restricted to preadipocytes in white adipose tissue. The absence of CRBP-I in mice (CRBP-I-KO mice) leads to increased adiposity. Despite increased adiposity, CRBP-I-KO mice remain more glucose tolerant and insulin sensitive during high-fat-diet feeding. 3T3-L1 cells deficient in CRBP-I or mouse embryonic fibroblasts derived from CRBP-I-KO mice had increased adipocyte differentiation and triglyceride (TG) accumulation. This was due to increased expression and activity of PPAR gamma, while other transcription factor pathways in early and late differentiation remained unchanged. Conversely, the overexpression of CRBP-I in 3T3-L1 cells results in decreased TG accumulation. In conclusion, CRBP-I is a cytosolic protein specifically expressed in preadipocytes that regulates adipocyte differentiation in part by affecting PPAR gamma activity.
Background. Despite considerable progress made in the past decade through salt iodization programs, over 2 billion people worldwide still have inadequate iodine intake, with devastating consequences for brain development and intellectual capacity. To optimize these programs with regard to salt iodine content, careful monitoring of salt iodine content is essential, but few methods are available to quantitatively measure iodine concentration in a simple, fast, and safe way.
Objective. We have validated a newly developed device that quantitatively measures the content of potassium iodate in salt in a simple, safe, and rapid way.
Methods. The linearity, determination and detection limit, and inter- and intra-assay variability of this colorimetric method were assessed and the method was compared with iodometric titration, using salt samples from several countries.
Results. Linearity of analysis ranged from 5 to 75 mg/kg iodine, with I mg/kg being the determination limit; the intra- and interassay imprecision was 0.9%, 0.5%, and 0.7% and 1.5%, 1.7%, and 2.5% for salt samples with iodine contents of 17, 30, and 55 mg/kg, respectively; the interoperator imprecision for the same samples was 1.2%, 4.9%, and 4.7%, respectively. Comparison with the iodometric method showed high agreement between the methods (R-2 = 0.978; limits of agreement, -10.5 to 10.0 mg/kg).
Conclusions. The device offers a field- and user-friendly solution to quantifying potassium iodate salt content reliably. For countries that use potassium iodide in salt iodization programs, further validation is required.