During the last decade microarrays have become a powerful analytical tool. Commonly microarrays are produced in a non-contact manner using silicone printheads. However, silicone printheads are expensive and not able to be used as a disposable. Here, we show the development and functional characterization of 8-channel plastic microarray printheads that overcome both disadvantages of their conventional silicone counterparts. A combination of injection-molding and laser processing allows us to produce a high quantity of cheap, customizable and disposable microarray printheads. The use of plastics (e.g., polystyrene) minimizes the need for surface modifications required previously for proper printing results. Time-consuming regeneration processes, cleaning procedures and contaminations caused by residual samples are avoided. The utilization of plastic printheads for viscous liquids, such as cell suspensions or whole blood, is possible. Furthermore, functional parts within the plastic printhead (e.g., particle filters) can be included. Our printhead is compatible with commercially available TopSpot devices but provides additional economic and technical benefits as compared to conventional TopSpot printheads, while fulfilling all requirements demanded on the latter. All in all, this work describes how the field of traditional microarray spotting can be extended significantly by low cost plastic printheads.
A direct competitive homogeneous immunoassay for progesterone - the Redox Quenching Immunoassay
(2012)
A direct competitive amperometric immunoassay format for the detection of haptens and proteins was developed. The method is based on the quenching of electroactivity of ferrocenium, which is coupled to the antigen and used as the primary reporter, upon binding to a monoclonal anti-ferrocenium antibody, which is coupled to the detection antibody and used as a secondary reporter. A separation-free progesterone immunoassay with a lower detection limit of 1 ng?mL-1 (3.18 nmol?L-1) in 1?:?2 diluted blood serum was realised by combining two bifunctional conjugates, a ferrocenium-PEG-progesterone tracer and a bioconjugate of one anti-progesterone and one anti-ferrocenium antibody. The immune complex is formed within 30 s upon addition of progesterone, resulting in a total analysis time of 1.5 min.
Changing functionality of surfaces by directed self-assembly using oligonucleotides - the oligo-tag
(1999)
The progesterone concentration in blood samples can be utilised as a marker for the diagnosis of early pregnancy, endocrinopathy and virilism. Here, we describe a method for progesterone detection and measurement in whole blood samples by a surface sensitive biosensor used in conjunction with an integrated optical grating coupler. This device determines refractive index changes near the biosensor's surface. Hence, biological species bound to a surface layer can be measured in real-time without any label. For the measurements, we have modified the indirect competitive immonoassay principle. The concentration of the progesterone antibody was kept at 1 µg/ml. Progesterone concentration was determined in buffer solution and whole blood in a range between 0.005 and 10 ng/ml. The detection limit was determined to be 3 pM. The relative standard deviation was calculated to be 3.5%.