Refine
Year of publication
Document Type
- Article (30)
- Postprint (4)
- Doctoral Thesis (2)
Keywords
Institute
Fluoroionophores of fluorophore-spacer-receptor format were prepared for detection of PdCl2 by fluorescence enhancement. The fluorophore probes 1-13 consist of a fluorophore group, in alkyl spacer and a dithiomaleonitrile PdCl2 receptor. First, varying the length of the alkylene spacer (compounds 1-3) revealed, dominant through-space pathway for oxidative photoinduced electron transfer (PET) in CH2-bridged dithiomaleonitrile fluoroionophores. Second. fluorescent probes 4-9 containing two anthracene or pyrene fragments connected through CH2 bridges to the dithiomaleonitrile unit were synthesized. Modulation of the oxidation potential (E-Ox) through electron-withdrawing or -donating groups on the anthracene moiety regulates file thermodynamic driving force for oxidative PET (Delta G(PET)) in bis(anthrylmethylthio)maleonitriles and therefore the fluorescence quantum yields (Phi(f)), too. The new concept was confirmed and transferred to pyrenyl ligands, and fluorescence enhancements (FE) greater than 3.2 in the presence of PdCl2 were achieved by 7 and 8 (FE=5.4 and 5.2). Finally, for comparison, monofluorophore ligands 10-13 were synthesized.
Fluoroionophores of fluorophore-spacer-receptor format were prepared for detection of PdCl2 by fluorescence enhancement. The fluorescent probes 1-13 consist of a fluorophore group, an alkyl spacer and a dithiomaleonitrile PdCl2 receptor. First, varying the length of the alkylene spacer (compounds 1-3) revealed a dominant through-space pathway for oxidative photoinduced electron transfer (PET) in CH2-bridged dithiomaleonitrile fluoroionophores. Second, fluorescent probes 4-9 containing two anthracene or pyrene fragments connected through CH2 bridges to the dithiomaleonitrile unit were synthesized. Modulation of the oxidation potential (EOx) through electron-withdrawing or -donating groups on the anthracene moiety regulates the thermodynamic driving force for oxidative PET (GPET) in bis(anthrylmethylthio)maleonitriles and therefore the fluorescence quantum yields (f), too. The new concept was confirmed and transferred to pyrenyl ligands, and fluorescence enhancements (FE) greater than 3.2 in the presence of PdCl2 were achieved by 7 and 8 (FE=5.4 and 5.2). Finally, for comparison, monofluorophore ligands 10-13 were synthesized.
In high-value sweet cherry (Prunus avium), the red coloration - determined by the anthocyanins content - is correlated with the fruit ripeness stage and market value. Non-destructive spectroscopy has been introduced in practice and may be utilized as a tool to assess the fruit pigments in the supply chain processes. From the fruit spectrum in the visible (Vis) wavelength range, the pigment contents are analyzed separately at their specific absorbance wavelengths.
A drawback of the method is the need for re-calibration due to varying optical properties of the fruit tissue. In order to correct for the scattering differences, most often the spectral intensity in the visible spectrum is normalized by wavelengths in the near infrared (NIR) range, or pre-processing methods are applied in multivariate calibrations.
In the present study, the influence of the fruit scattering properties on the Vis/NIR fruit spectrum were corrected by the effective pathlength in the fruit tissue obtained from time-resolved readings of the distribution of time-of-flight (DTOF). Pigment analysis was carried out according to Lambert-Beer law, considering fruit spectral intensities, effective pathlength, and refractive index. Results were compared to commonly applied linear color and multivariate partial least squares (PLS) regression analysis. The approaches were validated on fruits at different ripeness stages, providing variation in the scattering coefficient and refractive index exceeding the calibration sample set.
In the validation, the measuring uncertainty of non-destructively analyzing fruits with Vis/NIR spectra by means of PLS or Lambert-Beer in comparison with combined application of Vis/NIR spectroscopy and DTOF measurements showed a dramatic bias reduction as well as enhanced coefficients of determination when using both, the spectral intensities and apparent information on the scattering influence by means of DTOF readings. Corrections for the refractive index did not render improved results.