• Deutsch

University Logo

  • Home
  • Search
  • Browse
  • Submit
  • Sitemap
Schließen

Refine

Has Fulltext

  • no (55)
  • yes (7)

Author

  • Bittmann, Frank N. (62)
  • Badtke, Gernot (24)
  • Schaefer, Laura V. (12)
  • Lazik, Dieter (6)
  • Schmidt, Marco (6)
  • Kittel, Rene (5)
  • Schmidt, Ottmar (5)
  • Dech, Silas (4)
  • Luther, Sven (4)
  • Schaefer, Laura (4)
+ more

Year of publication

  • 2020 (6)
  • 2019 (1)
  • 2018 (3)
  • 2017 (5)
  • 2015 (1)
  • 2010 (1)
  • 2005 (2)
  • 2003 (4)
  • 2002 (5)
  • 2001 (1)
+ more

Document Type

  • Article (52)
  • Postprint (7)
  • Monograph/Edited Volume (3)

Language

  • German (39)
  • English (23)

Is part of the Bibliography

  • yes (62)

Keywords

  • Adaptive Force (5)
  • Holding isometric muscle action (3)
  • Mechanomyography (3)
  • Mechanotendography (3)
  • Pushing isometric muscle action (3)
  • Two forms of isometric muscle action (3)
  • muscle action (3)
  • O2C spectrophotometer (2)
  • adaptation to external force impact (2)
  • adaptive force (2)
+ more

Institute

  • Department Sport- und Gesundheitswissenschaften (48)
  • Strukturbereich Kognitionswissenschaften (10)
  • Humanwissenschaftliche Fakultät (2)
  • Institut für Biochemie und Biologie (2)

62 search hits

  • 1 to 10
  • BibTeX
  • CSV
  • RIS
  • XML
  • 10
  • 20
  • 50
  • 100

Sort by

  • Year
  • Year
  • Title
  • Title
  • Author
  • Author
Can chronic irritations of the trigeminal nerve cause musculoskeletal disorders? (2010)
Schmidt, Marco ; Hennke, Thomas ; Knochel, Mira ; Kurten, Achim ; Hierholzer, Johannes ; Daniel, Peter ; Bittmann, Frank N.
In this article, five cases of odontogenous dysfunctions and musculoskeletal complaints are presented. A common finding in all patients of this study was that the presence of joint complaints was related to deficits in the corresponding muscular function. These deficits were determined by manual muscle tests as described by Kendall et al. [Muscles - Testing and Function, ed 4. Baltimore, Williams and Wilkins, 1993] and were eliminated immediately by a neural therapeutic test injection into the disturbed dental region. The therapy provided solely aimed to eliminate the odontogenous dysfunction. No other therapeutic measures were carried out with regard to the patients' respective muscle, tendon, or joint complaints.
Untersuchungen des Zusammenhangs von äußerer Wirbelsäulenkurvatur und Funktion der posturalen Muskulatur (1997)
Schmidt, Marco ; Bittmann, Frank N. ; Lazik, Dieter
A new approach for objektive determination of the external spine profile in the sagittal plane (1998)
Schmidt, Marco ; Badtke, Gernot ; Bittmann, Frank N. ; Steuer, M.
Inhibitionen im neuromuskulären Reflexbogen als ein Faktor für rezidivierende Sportverletzungen und Überlastungsfolgen (2003)
Schmidt, Marco ; Badtke, Gernot ; Bittmann, Frank N.
Measuring system and method of determining the Adaptive Force (2017)
Schaefer, Laura V. ; Hoff, Marco ; Bittmann, Frank N.
The term Adaptive Force (AF) describes the capability of adaptation of the nerve-muscle-system to externally applied forces during isometric and eccentric muscle action. This ability plays an important role in real life motions as well as in sports. The focus of this paper is on the specific measurement method of this neuromuscular action, which can be seen as innovative. A measuring system based on the use of compressed air was constructed and evaluated for this neuromuscular function. It depends on the physical conditions of the subject, at which force level it deviates from the quasi isometric position and merges into eccentric muscle action. The device enables – in contrast to the isokinetic systems – a measure of strength without forced motion. Evaluation of the scientific quality criteria of the devices was done by measurements regarding the intra- and interrater-, the test-retest-reliability and fatiguing measurements. Comparisons of the pneumatic device with a dynamometer were also done. Looking at the mechanical evaluation, the results show a high level of consistency (r²=0.94 to 0.96). The parallel test reliability delivers a very high and significant correlation (ρ=0.976; p=0.000). Including the biological system, the concordance of three different raters is very high (p=0.001, Cronbachs alpha α=0.987). The test retest with 4 subjects over five weeks speaks for the reliability of the device in showing no statistically significant differences. These evaluations indicate that the scientific evaluation criteria are fulfilled. The specific feature of this system is that an isometric position can be maintained while the externally impacting force rises. Moreover, the device can capture concentric, static and eccentric strength values. Fields of application are performance diagnostics in sports and medicine.
Measuring system and method of determining the Adaptive Force (2017)
Schaefer, Laura V. ; Hoff, Marco ; Bittmann, Frank N.
The term Adaptive Force (AF) describes the capability of adaptation of the nerve-muscle-system to externally applied forces during isometric and eccentric muscle action. This ability plays an important role in real life motions as well as in sports. The focus of this paper is on the specific measurement method of this neuromuscular action, which can be seen as innovative. A measuring system based on the use of compressed air was constructed and evaluated for this neuromuscular function. It depends on the physical conditions of the subject, at which force level it deviates from the quasi isometric position and merges into eccentric muscle action. The device enables – in contrast to the isokinetic systems – a measure of strength without forced motion. Evaluation of the scientific quality criteria of the devices was done by measurements regarding the intra- and interrater-, the test-retest-reliability and fatiguing measurements. Comparisons of the pneumatic device with a dynamometer were also done. Looking at the mechanical evaluation, the results show a high level of consistency (r²=0.94 to 0.96). The parallel test reliability delivers a very high and significant correlation (ρ=0.976; p=0.000). Including the biological system, the concordance of three different raters is very high (p=0.001, Cronbachs alpha α=0.987). The test retest with 4 subjects over five weeks speaks for the reliability of the device in showing no statistically significant differences. These evaluations indicate that the scientific evaluation criteria are fulfilled. The specific feature of this system is that an isometric position can be maintained while the externally impacting force rises. Moreover, the device can capture concentric, static and eccentric strength values. Fields of application are performance diagnostics in sports and medicine.
Coherent behavior of neuromuscular oscillations between isometrically interacting subjects (2018)
Schaefer, Laura V. ; Bittmann, Frank N.
Previous research has shown that electrical muscle activity is able to synchronize between muscles of one subject. The ability to synchronize the mechanical muscle oscillations measured by Mechanomyography (MMG) is not described sufficiently. Likewise, the behavior of myofascial oscillations was not considered yet during muscular interaction of two human subjects. The purpose of this study is to investigate the myofascial oscillations intra- and interpersonally. For this the mechanical muscle oscillations of the triceps and the abdominal external oblique muscles were measured by MMG and the triceps tendon was measured by mechanotendography (MTG) during isometric interaction of two subjects (n = 20) performed at 80% of the MVC using their arm extensors. The coherence of MMG/MTG-signals was analyzed with coherence wavelet transform and was compared with randomly matched signal pairs. Each signal pairing shows significant coherent behavior. Averagely, the coherent phases of n = 485 real pairings last over 82 ± 39 % of the total duration time of the isometric interaction. Coherent phases of randomly matched signal pairs take 21 ± 12 % of the total duration time (n = 39). The difference between real vs. randomly matched pairs is significant (U = 113.0, p = 0.000, r = 0.73). The results show that the neuromuscular system seems to be able to synchronize to another neuromuscular system during muscular interaction and generate a coherent behavior of the mechanical muscular oscillations. Potential explanatory approaches are discussed.
Coherent behavior of neuromuscular oscillations between isometrically interacting subjects (2018)
Schaefer, Laura V. ; Bittmann, Frank N.
Previous research has shown that electrical muscle activity is able to synchronize between muscles of one subject. The ability to synchronize the mechanical muscle oscillations measured by Mechanomyography (MMG) is not described sufficiently. Likewise, the behavior of myofascial oscillations was not considered yet during muscular interaction of two human subjects. The purpose of this study is to investigate the myofascial oscillations intra- and interpersonally. For this the mechanical muscle oscillations of the triceps and the abdominal external oblique muscles were measured by MMG and the triceps tendon was measured by mechanotendography (MTG) during isometric interaction of two subjects (n = 20) performed at 80% of the MVC using their arm extensors. The coherence of MMG/MTG-signals was analyzed with coherence wavelet transform and was compared with randomly matched signal pairs. Each signal pairing shows significant coherent behavior. Averagely, the coherent phases of n = 485 real pairings last over 82 ± 39 % of the total duration time of the isometric interaction. Coherent phases of randomly matched signal pairs take 21 ± 12 % of the total duration time (n = 39). The difference between real vs. randomly matched pairs is significant (U = 113.0, p = 0.000, r = 0.73). The results show that the neuromuscular system seems to be able to synchronize to another neuromuscular system during muscular interaction and generate a coherent behavior of the mechanical muscular oscillations. Potential explanatory approaches are discussed.
Are there two forms of isometric muscle action? (2017)
Schaefer, Laura V. ; Bittmann, Frank N.
Background In isometric muscle function, there are subjectively two different modes of performance: one can either hold isometrically – thus resist an impacting force – or push isometrically – therefore work against a stable resistance. The purpose of this study is to investigate whether or not two different isometric muscle actions – the holding vs. pushing one (HIMA vs PIMA) – can be distinguished by objective parameters. Methods Ten subjects performed two different measuring modes at 80% of MVC realized by a special pneumatic system. During HIMA the subject had to resist the defined impacting force of the pneumatic system in an isometric position, whereby the force of the cylinder works in direction of elbow flexion against the subject. During PIMA the subject worked isometrically in direction of elbow extension against a stable position of the system. The signals of pressure, force, acceleration and mechanomyography/-tendography (MMG/MTG) of the elbow extensor (MMGtri/MTGtri) and the abdominal muscle (MMGobl) were recorded and evaluated concerning the duration of maintaining the force level (force endurance) and the characteristics of MMG-/MTG-signals. Statistical group differences comparing HIMA vs. PIMA were estimated using SPSS. Results Significant differences between HIMA and PIMA were especially apparent regarding the force endurance: During HIMA the subjects showed a decisively shorter time of stable isometric position (19 ± 8 s) in comparison with PIMA (41 ± 24 s; p = .005). In addition, during PIMA the longest isometric plateau amounted to 59.4% of the overall duration time of isometric measuring, during HIMA it lasted 31.6% (p = .000). The frequency of MMG/MTG did not show significant differences. The power in the frequency ranges of 8–15 Hz and 10–29 Hz was significantly higher in the MTGtri performing HIMA compared to PIMA (but not for the MMGs). The amplitude of MMG/MTG did not show any significant difference considering the whole measurement. However, looking only at the last 10% of duration time (exhaustion), the MMGtri showed significantly higher amplitudes during PIMA. Conclusion The results suggest that under holding isometric conditions muscles exhaust earlier. That means that there are probably two forms of isometric muscle action. We hypothesize two potential reasons for faster yielding during HIMA: (1) earlier metabolic fatigue of the muscle fibers and (2) the complexity of neural control strategies.
Are there two forms of isometric muscle action? (2017)
Schaefer, Laura V. ; Bittmann, Frank N.
Background In isometric muscle function, there are subjectively two different modes of performance: one can either hold isometrically – thus resist an impacting force – or push isometrically – therefore work against a stable resistance. The purpose of this study is to investigate whether or not two different isometric muscle actions – the holding vs. pushing one (HIMA vs PIMA) – can be distinguished by objective parameters. Methods Ten subjects performed two different measuring modes at 80% of MVC realized by a special pneumatic system. During HIMA the subject had to resist the defined impacting force of the pneumatic system in an isometric position, whereby the force of the cylinder works in direction of elbow flexion against the subject. During PIMA the subject worked isometrically in direction of elbow extension against a stable position of the system. The signals of pressure, force, acceleration and mechanomyography/-tendography (MMG/MTG) of the elbow extensor (MMGtri/MTGtri) and the abdominal muscle (MMGobl) were recorded and evaluated concerning the duration of maintaining the force level (force endurance) and the characteristics of MMG-/MTG-signals. Statistical group differences comparing HIMA vs. PIMA were estimated using SPSS. Results Significant differences between HIMA and PIMA were especially apparent regarding the force endurance: During HIMA the subjects showed a decisively shorter time of stable isometric position (19 ± 8 s) in comparison with PIMA (41 ± 24 s; p = .005). In addition, during PIMA the longest isometric plateau amounted to 59.4% of the overall duration time of isometric measuring, during HIMA it lasted 31.6% (p = .000). The frequency of MMG/MTG did not show significant differences. The power in the frequency ranges of 8–15 Hz and 10–29 Hz was significantly higher in the MTGtri performing HIMA compared to PIMA (but not for the MMGs). The amplitude of MMG/MTG did not show any significant difference considering the whole measurement. However, looking only at the last 10% of duration time (exhaustion), the MMGtri showed significantly higher amplitudes during PIMA. Conclusion The results suggest that under holding isometric conditions muscles exhaust earlier. That means that there are probably two forms of isometric muscle action. We hypothesize two potential reasons for faster yielding during HIMA: (1) earlier metabolic fatigue of the muscle fibers and (2) the complexity of neural control strategies.
  • 1 to 10

OPUS4 Logo  KOBV Logo  OAI Logo  DINI Zertifikat 2007  OA Netzwerk Logo

    • Publication server
    • University Bibliography
    • University Library
    • Policy
    • Contact
    • Imprint
    • Privacy Policy
    • Accessibility

    Login