Refine
Language
- English (5)
Is part of the Bibliography
- yes (5)
Keywords
- Vitamin A (5) (remove)
Institute
- Institut für Ernährungswissenschaft (5) (remove)
Background: Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC).
Methods: The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP).
Results: Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r2 = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison.
Conclusions: With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.
Background: Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC).
Methods: The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP).
Results: Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r2 = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison.
Conclusions: With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.
Vitamin A deficiency continues to be a global public health problem. Fortification of oil with vitamin A is considered a cost-effective, feasible strategy to prevent this problem but quality control poses a challenge to program implementation. To overcome this, we have validated a newly developed device that quantitatively measures the content of retinyl palmitate in refined palm oil, is simple to use, and yields immediate results.
Linearity of analysis rand from 2.5-30 mg retinol equivalents (RE)/kg of palm oil, with 2.5 mg RE/kg being the determination limit; inter- and intra-assay precision ranged from 1.4-7.1 To. Comparison with a high-performance Liquid chromatography method showed high agreement between the methods (R-2 = 0.92; Limits of Agreement: -1.24 mg to 2.53 mg RE/kg), and further comparisons illustrate that the new device is useful in low resource settings. This device offers a field- and user-friendly solution to quantifying the vitamin A content in refined palm oil.
To study the role of the TTR-RBP4-ROH complex components (transthyretin, serum retinol binding protein, retinol) and of angiogenic factors PlGF (placental growth factor) and sFlt-1 (soluble fms-like tyrosine kinase-1) in pregnancies complicated by small for gestational age infants (SGA). Case control study conducted on maternal serum collected between 11 + 0 to 13 + 6 weeks of gestation. TTR, RBP4, ROH, PlGF and sFlt-1 were measured in SGA patients (birth weight < 10%) who delivered at term (n = 37) and before 37 weeks of gestation (n = 17) and in a matched control group with uneventful pregnancies (n = 37). We found decreased RBP4 in SGA patients that delivered fetuses < 3% and in fetuses delivered after the 37 weeks of gestation compared to controls [1.50 (95% CI 1.40-1.75) vs 1.62 (95% CI 1.47-1.98), p < 0.05]. Further, we found lower PlGF and sFlt-1 concentrations in SGA that delivered before 37 weeks of gestation compared to controls (respectively, PIGF and sFlt-1: 39.7 pg/ml (95% CI 32.3-66.3) vs 62.9 pg/ml (95% CI 45.2-78.4) and 906 pg/ml (95% CI 727-1626) vs 1610 pg/ml (95% CI 1088-212), p < 0.05). First trimester maternal serum RBP4 and angiogenic factors PlGF and sFlt-1 can differently predict the timing of delivery of pregnancies complicated by SGA fetuses.
Research in rodents has shown that dietary vitamin A reduces body fat by enhancing fat mobilisation and energy utilisation; however, their effects in growing dogs remain unclear. In the present study, we evaluated the development of body weight and body composition and compared observed energy intake with predicted energy intake in forty-nine puppies from two breeds (twenty-four Labrador Retriever (LAB) and twenty-five Miniature Schnauzer (MS)). A total of four different diets with increasing vitamin A content between 5.24 and 104.80 mu mol retinol (5000-100 000 IU vitamin A)/4184 kJ (1000 kcal) metabolisable energy were fed from the age of 8 weeks up to 52 (MS) and 78 weeks (LAB). The daily energy intake was recorded throughout the experimental period. The body condition score was evaluated weekly using a seven-category system, and food allowances were adjusted to maintain optimal body condition. Body composition was assessed at the age of 26 and 52 weeks for both breeds and at the age of 78 weeks for the LAB breed only using dual-energy X-ray absorptiometry. The growth curves of the dogs followed a breed-specific pattern. However, data on energy intake showed considerable variability between the two breeds as well as when compared with predicted energy intake. In conclusion, the data show that energy intakes of puppies particularly during early growth are highly variable; however, the growth pattern and body composition of the LAB and MS breeds are not affected by the intake of vitamin A at levels up to 104.80 mu mol retinol (100 000 IU vitamin A)/4184 kJ (1000 kcal).