Refine
Has Fulltext
- no (30)
Year of publication
Document Type
- Other (30) (remove)
Is part of the Bibliography
- yes (30)
Keywords
- Monte-Carlo simulations (1)
- Near infrared (1)
- OH suppression (1)
- PHEMA (1)
- Photon Density Wave Spectroscopy (1)
- SAW impedance sensor (1)
- Time-resolved crystallography (1)
- algae cultivation (1)
- astrophotonics (1)
- crystallography (1)
Institute
- Institut für Chemie (30) (remove)
Monte-Carlo calculations are carried out to simulate the light transport in dense materials. Focus lies on the calculation of diffuse light transmission through films of scattering and absorbing media considering additionally the effect of dependent scattering. Different influences like interaction type between particles, particle size, composition etc. can be studied by this program. Simulations in this study show major influences on the diffuse transmission. Further simulations are carried out to model a sunscreen film and study best compositions of this film and will be presented.
The problem of atmospheric emission from OH molecules is a long standing problem for near-infrared astronomy. PRAXIS is a unique spectrograph which is fed by fibres that remove the OH background and is optimised specifically to benefit from OH-Suppression. The OH suppression is achieved with fibre Bragg gratings, which were tested successfully on the GNOSIS instrument. PRAXIS uses the same fibre Bragg gratings as GNOSIS in its first implementation, and will exploit new, cheaper and more efficient, multicore fibre Bragg gratings in the second implementation. The OH lines are suppressed by a factor of similar to 1000, and the expected increase in the signal-to-noise in the interline regions compared to GNOSIS is a factor of similar to 9 with the GNOSIS gratings and a factor of similar to 17 with the new gratings. PRAXIS will enable the full exploitation of OH suppression for the first time, which was not achieved by GNOSIS (a retrofit to an existing instrument that was not OH-Suppression optimised) due to high thermal emission, low spectrograph transmission and detector noise. PRAXIS has extremely low thermal emission, through the cooling of all significantly emitting parts, including the fore-optics, the fibre Bragg gratings, a long length of fibre, and the fibre slit, and an optical design that minimises leaks of thermal emission from outside the spectrograph. PRAXIS has low detector noise through the use of a Hawaii-2RG detector, and a high throughput through a efficient VPH based spectrograph. PRAXIS will determine the absolute level of the interline continuum and enable observations of individual objects via an IFU. In this paper we give a status update and report on acceptance tests.
Stable covalently photo-cross-linked porous poly(ionic liquid) membrane with gradient pore size
(2018)
Porous polyelectrolyte membranes stable in a highly ionic environment are obtained by covalent crosslinking of an imidazolium-based poly(ionic liquid). The crosslinking reaction involves the UV light-induced thiol-ene (click) chemistry, and the phase separation, occurring during the crosslinking step, generates a fully interconnected porous structure in the membrane. The porosity is on the order of the micrometer scale and the membrane shows a gradient of pore size across the membrane cross-section. The membrane can separate polystyrene latex particles of different size and undergoes actuation in contact with acetone due to the asymmetric porous structure.