Refine
Year of publication
Document Type
- Article (20)
- Postprint (4)
- Other (2)
- Part of a Book (1)
Keywords
Institute
Depletion-induced flocculation of concentrated emulsions probed by photon density wave spectroscopy
(2020)
Stable, creaming-free oil in water emulsions with high volume fractions of oil (phi = 0.05-0.40, density matched to water) and polysorbate 80 as an emulsifier were characterized without dilution by Photon Density Wave spectroscopy measuring light absorption and scattering behavior, the latter serving as the basis for droplet size distribution analysis. The emulsion with phi = 0.10 was used to investigate flocculation processes induced by xanthan as a semi-flexible linear nonabsorbing polymer. Different time regimes in the development of the reduced scattering coefficient mu(s)' could be identified. First, a rapid, temperature-dependent change in mu(s)' during the depletion process was observed. Second, the further decrease of mu(s)' follows a power law in analogy to a spinodal demixing behavior, as described by the Cahn-Hilliard theory.
We report on the fabrication, modeling, and experimental verification of the emission of fiber lenses fabricated on multimode fibers in different media. Concave fiber lenses with a radius of 150 mu m were fabricated onto a multimode silica fiber (100 mu m core) by grinding and polishing against a ruby sphere template. In our theoretical model we assume that the fiber guides light from a Lambertian light source and that the emission cone is governed solely by the range of permitted emission angles. We investigate concave and convex lenses at 532 nm with different radii and in a variety of surrounding media from air (n(0) = 1.00) to sapphire (n(0) = 1.77). It was found that noticeable focusing or defocusing effects of a silica fiber lens in ethanol (n(0) = 1.36) and dimethyl sulfoxide (DMSO) (n(0) = 1.48) are only observed when the fiber lens radius was less than the fiber diameter.
We demonstrate a method for the calibration-free and quantitative analysis of small volumes of gaseous samples. A 10 m hollow-core photonic bandgap fiber is used as the sample cell (volume = 0.44 mu L) and is placed inside a linear resonator setup. The application of cavity ring-down spectroscopy and in consideration of rather small coupling losses, this leads to an increased effective optical path length of up to 70 m. This implies a volume per optical interaction path length of 6.3 nL.m(-1). We used tunable diode laser spectroscopy at 760 nm and scanned the absorption for oxygen sensing. The optical loss due to sample absorption is obtained by measuring the ring-down time of light propagating inside the cavity. The resultant absorption coefficient shows a discrepancy of only 5.1% comparing to the HITRAN database. This approach is applicable for sensitive measurements if only submicroliter sample volumes are available.
We present a fluorescence excitation-emission-matrix spectrometer with superior data acquisition rates over previous instruments. Light from a white light emitting diode (LED) source is dispersed onto a digital micromirror array (DMA) and encoded using binary n-size Walsh functions ("barcodes"). The encoded excitation light is used to irradiate the liquid sample and its fluorescence is dispersed and detected using a conventional array spectrometer. After exposure to excitation light encoded in n different ways, the 2-dimensional excitation-emission-matrix (EEM) spectrum is obtained by inverse Hadamard transformation. Using this technique we examined the kinetics of the fluorescence of rhodamine B as a function of temperature and the acid-driven demetalation of chlorophyll into pheophytin-a. For these experiments, EEM spectra with 31 excitation channels and 2048 emission channels were recorded every 15 s. In total, data from over 3000 EEM spectra were included in this report. It is shown that the increase in data acquisition rate can be as high as [{n(n + 1)}/2]-fold over conventional EEM spectrometers. Spectral acquisition rates of more than two spectra per second were demonstrated.
We describe an in-fiber interferometer based on a gas-filled hollow-core photonic crystal fiber. Expressions for the sensitivity, figure of merit and refractive index resolution are derived, and values are experimentally measured and theoretically validated using mode field calculations. The refractive indices of nine monoatomic and molecular gases are measured with a resolution of delta(ns) < 10(-6). (C)2016 Optical Society of America
Electronic intensity and frequency modulation of diode lasers enables new perspectives for highly sensitive analytical in-situ techniques. For analyis of "heterogeneous" media, which may consist of coexisting gaseous, liquid, and solid phases and often show multiple light scattering, non-invasive techniques with outstanding performance characteristics can be developed. Analysis of photon density waves launched by intensity-modulated lasers provide an elegant way for the determination of absorption and scattering coefficients of multiple scattering media. The absorption coefficient can be used for qualitative and quantitative analysis of chemical constituents (which absorb in the range of the laser wavelengths). The scattering coefficient allows characterization of physical and morphological properties of the sample. In the current work, applicability of appropriate radiation transport models was investigated with simple light scattering solutions and compared with results obtained from the treatment according to the theory of Kubelka and Munk. Measurements of human blood samples are discussed. A new method for determination of water vapor partial pressure in a polyurethane foam with a frequency-modulated external cavity diode laser is discussed.
Industrial applications of photon density wave spectroscopy for in-line particle sizing [Invited]
(2013)
Optical spectroscopy in highly turbid liquid material is often restricted by simultaneous occurrence of absorption and scattering of light. Photon Density Wave (PDW) spectroscopy is one of the very few, yet widely unknown, technologies for the independent quantification of these two optical processes. Here, a concise overview about modern PDW spectroscopy is given, including all necessary equations concerning the optical description of the investigated material, dependent light scattering, particle sizing, and PDW spectroscopy itself. Additionally, it is shown how the ambiguity in particle sizing, arising from Mie theory, can be correctly solved. Due to its high temporal resolution, its applicability to highest particle concentrations, and its purely fiber-optical probe, PDW spectroscopy possesses all fundamental characteristics for optical in-line process analysis. Several application examples from the chemical industry are presented. (C) 2013 Optical Society of America
Objective Due to multiple light scattering that occurs inside and between cells, quantitative optical spectroscopy in turbid biological suspensions is still a major challenge. This includes also optical inline determination of biomass in bioprocessing. Photon Density Wave (PDW) spectroscopy, a technique based on multiple light scattering, enables the independent and absolute determination of optical key parameters of concentrated cell suspensions, which allow to determine biomass during cultivation. Results A unique reactor type, called "mesh ultra-thin layer photobioreactor" was used to create a highly concentrated algal suspension. PDW spectroscopy measurements were carried out continuously in the reactor without any need of sampling or sample preparation, over 3 weeks, and with 10-min time resolution. Conventional dry matter content and coulter counter measurements have been employed as established offline reference analysis. The PBR allowed peak cell dry weight (CDW) of 33.4 g L-1. It is shown that the reduced scattering coefficient determined by PDW spectroscopy is strongly correlated with the biomass concentration in suspension and is thus suitable for process understanding. The reactor in combination with the fiber-optical measurement approach will lead to a better process management.
Die Inline-Bestimmung von Teilchengroeßen in Emulsionen und Suspensionen stellt besondere Anforderungen an die Messtechnik, da auch bei sehr hohen Teilchenkonzentrationen im Prozess verduennungsfreie Analytik betrieben werden soll. Neben einer Klaerung der Begriffe atline, online und in-line gibt der Beitrag eine Einfuehrung in die mathematische Beschreibung von Groeßenverteilungen. Als Inline-Techniken werden Photonendichtewellen-Spektroskopie, Focused Beam Reflectance Measurement und Ultraschallextinktion-Spektroskopie diskutiert und ihre sehr unterschiedlichen physikalischen Messprinzipien erlaeutert. Auch wird kurz erklaert, wie Teilchengroeßen aus den Messresultaten erhalten werden. Die wesentlichen Charakteristika dieser drei Methoden werden abschließend im ueberblick dargestellt.