Refine
Year of publication
Document Type
Is part of the Bibliography
- yes (113)
Keywords
- Cardiac rehabilitation (19)
- cardiac rehabilitation (16)
- rehabilitation (8)
- TAVI (7)
- Return to work (5)
- Telerehabilitation (5)
- coronary artery disease (5)
- mortality (5)
- Frailty (4)
- elderly (4)
Institute
- Department Sport- und Gesundheitswissenschaften (54)
- Strukturbereich Kognitionswissenschaften (26)
- Humanwissenschaftliche Fakultät (13)
- Fakultät für Gesundheitswissenschaften (5)
- Department Psychologie (2)
- Extern (2)
- Hochschulambulanz (2)
- Institut für Biochemie und Biologie (2)
- Institut für Ernährungswissenschaft (2)
- Gesundheitsmanagement (1)
Objective: To determine immediate performance measures for short-term, multicomponent cardiac rehabilitation (CR) in clinical routine in patients of working age, taking into
account cardiovascular risk factors, physical performance, social medicine, and subjective health parameters and to explore the underlying dimensionality.
Design: Prospective observational multicenter register study in 12 rehabilitation centers throughout Germany.
Setting: Comprehensive 3-week CR.
Objective: To determine immediate performance measures for short-term, multicomponent cardiac rehabilitation (CR) in clinical routine in patients of working age, taking into
account cardiovascular risk factors, physical performance, social medicine, and subjective health parameters and to explore the underlying dimensionality.
Design: Prospective observational multicenter register study in 12 rehabilitation centers throughout Germany.
Setting: Comprehensive 3-week CR.
Research question: The purpose of this study was to evaluate the test-retest reliability of lower extremity kinematics during squat, hip abduction and lunge exercises captured by the Kinect and to evaluate the agreement to a reference 3D camera-based motion system. Methods: Twenty-one healthy individuals performed five repetitions of each lower limb exercise on two different days. Movements were simultaneously assessed by the Kinect and the reference 3D motion system. Joint angles and positions of the lower limb were calculated for sagittal and frontal plane. For the inter-session reliability and the agreement between the two systems standard error of measurement (SEM), bias with limits of agreement (LoA) and Pearson Correlation Coefficient (r) were calculated. Results: Parameters indicated varying reliability for the assessed joint angles and positions and decreasing reliability with increasing task complexity. Across all exercises, measurement deviations were shown especially for small movement amplitudes. Variability was acceptable for joint angles and positions during the squat, partially acceptable during the hip abduction and predominately inacceptable during the lunge. The agreement between systems was characterized by systematic errors. Overestimations by the Kinect were apparent for hip flexion during the squat and hip abduction/adduction during the hip abduction exercise as well as for the knee positions during the lunge. Knee and hip flexion during hip abduction and lunge were underestimated by the Kinect. Significance: The Kinect system can reliably assess lower limb joint angles and positions during simple exercises. The validity of the system is however restricted. An application in the field of early orthopedic rehabilitation without further development of post-processing techniques seems so far limited.
Hintergrund
Eine Verlängerung der Lebens- und Arbeitszeit erfordert einen aktiven Lebensstil, eine Optimierung von kardiovaskulären Risikofaktoren und psychosoziale Unterstützung chronisch Herzkranker.
Fragestellung
Können die Prognose und Lebensqualität sowie die soziale oder berufliche Teilhabe kardiovaskulär Erkrankter durch kardiologische Rehabilitation (KardReha) verbessert werden?
Material und Methode
Auf der Grundlage neuer Metaanalysen und aktueller Positionspapiere gibt die S3-Leitlinie zur kardiologischen Rehabilitation evidenzbasierte Empfehlungen.
Ergebnisse
Eine KardReha reduziert bei Patienten nach akutem Koronarsyndrom, nach PCI („percutaneous coronary interventions“) oder nach aortokoronarer Koronarbypassoperation (ACB-Op.) sowie nach Klappenkorrektur die Gesamtsterblichkeit. Bei Patienten mit systolischer Herzinsuffizienz (HFrEF [„heart failure with reduced ejection fraction“]) werden Belastbarkeit und Lebensqualität durch eine KardReha verbessert. Psychosozialer Distress kann verringert und die berufliche Wiedereingliederung besser strukturiert werden.
Schlussfolgerung
Im Jahr 2019 liegen aktuelle, evidenzbasierte Leitlinien vor, die aufgrund verbesserter Prognose, Belastbarkeit und Lebensqualität eine multimodale kardiologische Rehabilitation bei Patienten nach akutem kardialem Ereignis auch bei technischem Fortschritt (z. B. katheterbasierter Klappenkorrektur) und unter Aspekten der sozialen und beruflichen Teilhabe empfehlen.
Background Transcatheter aortic-valve implantation (TAVI) is an established alternative therapy in patients with severe aortic stenosis and a high surgical risk. Despite a rapid growth in its use, very few data exist about the efficacy of cardiac rehabilitation (CR) in these patients. We assessed the hypothesis that patients after TAVI benefit from CR, compared to patients after surgical aortic-valve replacement (sAVR).
Methods From September 2009 to August 2011, 442 consecutive patients after TAVI (n=76) or sAVR (n=366) were referred to a 3-week CR. Data regarding patient characteristics as well as changes of functional (6-min walk test. 6-MWT), bicycle exercise test), and emotional status (Hospital Anxiety and Depression Scale) were retrospectively evaluated and compared between groups after propensity score adjustment.
Results Patients after TAVI were significantly older (p<0.001), more female (p<0.001), and had more often coronary artery disease (p=0.027), renal failure (p=0.012) and a pacemaker (p=0.032). During CR, distance in 6-MWT (both groups p0.001) and exercise capacity (sAVR p0.001, TAVI p0.05) significantly increased in both groups. Only patients after sAVR demonstrated a significant reduction in anxiety and depression (p0.001). After propensity scores adjustment, changes were not significantly different between sAVR and TAVI, with the exception of 6-MWT (p=0.004).
Conclusions Patients after TAVI benefit from cardiac rehabilitation despite their older age and comorbidities. CR is a helpful tool to maintain independency for daily life activities and participation in socio-cultural life.
Background Transcatheter aortic-valve implantation (TAVI) is an established alternative therapy in patients with severe aortic stenosis and a high surgical risk. Despite a rapid growth in its use, very few data exist about the efficacy of cardiac rehabilitation (CR) in these patients. We assessed the hypothesis that patients after TAVI benefit from CR, compared to patients after surgical aortic-valve replacement (sAVR).
Methods From September 2009 to August 2011, 442 consecutive patients after TAVI (n=76) or sAVR (n=366) were referred to a 3-week CR. Data regarding patient characteristics as well as changes of functional (6-min walk test. 6-MWT), bicycle exercise test), and emotional status (Hospital Anxiety and Depression Scale) were retrospectively evaluated and compared between groups after propensity score adjustment.
Results Patients after TAVI were significantly older (p<0.001), more female (p<0.001), and had more often coronary artery disease (p=0.027), renal failure (p=0.012) and a pacemaker (p=0.032). During CR, distance in 6-MWT (both groups p0.001) and exercise capacity (sAVR p0.001, TAVI p0.05) significantly increased in both groups. Only patients after sAVR demonstrated a significant reduction in anxiety and depression (p0.001). After propensity scores adjustment, changes were not significantly different between sAVR and TAVI, with the exception of 6-MWT (p=0.004).
Conclusions Patients after TAVI benefit from cardiac rehabilitation despite their older age and comorbidities. CR is a helpful tool to maintain independency for daily life activities and participation in socio-cultural life.
Background: The LumiraDx INR Test is a new point-of-care diagnostic test designed to analyze fingerstick blood samples. The test was assessed in patients receiving phenprocoumon (NCT04074980).
Methods: Venous plasma international normalized ratio (INR) was measured using the LumiraDx INR Test. LumiraDx INR Test-ascertained capillary whole blood INR was compared with venous plasma INR measured using the IL ACL Elite Pro and Sysmex CS-5100 reference instruments.
Results: A total of 102 patients receiving phenprocoumon were recruited. The INR results from venous plasma and capillary whole blood that were analyzed on the LumiraDx INR Test correlated well with those measured using the IL ACL Elite Pro (plasma: n = 25, r = 0.981; capillary blood: n = 74, r = 0.949) and the Sysmex CS-5100 (n = 73, r = 0.950).
Conclusions: The LumiraDx INR Test showed high accuracy in analyzing venous plasma and capillary whole blood from patients receiving phenprocoumon.