Refine
Year of publication
Document Type
- Article (37)
- Postprint (13)
- Conference Proceeding (12)
- Habilitation Thesis (1)
- Other (1)
- Review (1)
Is part of the Bibliography
- yes (65)
Keywords
- sonography (15)
- young athletes (7)
- neovascularization (5)
- neuromuscular (5)
- achilles tendinopathy (4)
- advanced dynamic flow (4)
- tendinopathy (4)
- training adaptation (4)
- ultrasound (4)
- Achilles and patellar tendon (3)
- Achilles tendon (3)
- Doppler ultrasound (3)
- SEMG-pattern (3)
- back pain (3)
- drop jump (3)
- epidemiology (3)
- musculoskeletal (3)
- non-athletes (3)
- performance (3)
- pre-activity (3)
- reliability (3)
- trunk (3)
- Advanced Dynamic Flow (2)
- Athletes (2)
- Calorimetry (2)
- ECG (2)
- Energy requirement (2)
- Fat-free mass (2)
- HI-RTE (2)
- Injury (2)
- Nutritional counseling (2)
- Pain occurrence (2)
- Tendinopathy (2)
- Training volume (2)
- Ultrasonography (2)
- Young athletes (2)
- athlete (2)
- athletes (2)
- biomechanics (2)
- complaints (2)
- echocardiography (2)
- elasticity imaging (2)
- electromyography (2)
- elite athletes (2)
- hypoechogenicities (2)
- isokinetic (2)
- kinematics (2)
- kinetics (2)
- overuse injuries (2)
- paediatric athlete (2)
- plantar fascia (2)
- pre-participation screening (2)
- real-time tissue elastography (2)
- reproducibility (2)
- risk factors (2)
- runners (2)
- sonoelastography (2)
- sports (2)
- sudden cardiac death (2)
- symptoms (2)
- tendinosis (2)
- ultrasonography (2)
- vascularization (2)
- Adaptation (1)
- Ankle joint (1)
- Athletic loading (1)
- Axillary lymph nodes (1)
- Breast ultrasound (1)
- Cancer detection (1)
- Dietary supplements (1)
- Elasticity imaging (1)
- Electromyography (1)
- Elite athletes (1)
- Lymph node metastases (1)
- Minerals (1)
- Overuse injury (1)
- Patella tendon (1)
- Prevalence (1)
- Real-time tissue elastography (1)
- Running gait (1)
- Sonoelastography (1)
- Tendon structure (1)
- Tolerable upper limits (1)
- Ultrasound (1)
- VO2mdx (1)
- Vitamins (1)
- achilles and patellar tendon (1)
- adolescent athletes (1)
- ankle joint rotation (1)
- axillary lymph nodes (1)
- body composition (1)
- breast tissue (1)
- breast ultrasound (1)
- cancer detection (1)
- cardiopulmonary exercise testing (1)
- children (1)
- compliance (1)
- dietary supplements (1)
- doppler ultrasound (1)
- dynamic (1)
- gastrocnemius muscle (1)
- hyperechogenicities (1)
- hyperemia (1)
- inter-rater variability (1)
- intra- and inter-rater variability (1)
- intratendinous blood flow (1)
- lactate threshold (1)
- locomotion (1)
- lymph node metastases (1)
- metabolic device (1)
- minerals (1)
- muscle architecture (1)
- musculoskeletal ultrasound (1)
- neuromuscular control (1)
- performance diagnostics (1)
- principles of therapy (1)
- running gait (1)
- skinfold thickness (1)
- standard values (1)
- subcutaneous adipose tissue (1)
- tendon diameter (1)
- tendon thickness (1)
- tolerable upper limits (1)
- training volume (1)
- vitamins (1)
Tendinopathies are frequently the cause of chronic, load-dependent complaints of the lower extremity. Commonly, the large tendons of the ankle and knee joints are affected, especially the Achilles and patellar tendons. Repeated overuse in sports and/or daily activities is assumed as the aetiology. Besides the clinical examination including a comprehensive anamnesis of pain and training/loading, sonographic imaging has a high training/loading relevance for the diagnosis of tendon pathologies of the lower extremity. Training concepts are considered in first line as the treatment of choice. A combination with physical therapy interventions can be useful. In cases of a more severe pathology and long-standing complaints multimodal therapeutic options should be employed. The use of surgical treatment procedures should only be taken into account in case of failed response to conservative treatment.
Background: Athletes may differ in their resting metabolic rate (RMR) from the general population. However, to estimate the RMR in athletes, prediction equations that have not been validated in athletes are often used. The purpose of this study was therefore to verify the applicability of commonly used RMR predictions for use in athletes. Methods: The RMR was measured by indirect calorimetry in 17 highly trained rowers and canoeists of the German national teams (BMI 24 ± 2 kg/m2, fat-free mass 69 ± 15 kg). In addition, the RMR was predicted using Cunningham (CUN) and Harris-Benedict (HB) equations. A two-way repeated measures ANOVA was calculated to test for differences between predicted and measured RMR (α = 0.05). The root mean square percentage error (RMSPE) was calculated and the Bland-Altman procedure was used to quantify the bias for each prediction. Results: Prediction equations significantly underestimated the RMR in males (p < 0.001). The RMSPE was calculated to be 18.4% (CUN) and 20.9% (HB) in the entire group. The bias was 133 kcal/24 h for CUN and 202 kcal/24 h for HB. Conclusions: Predictions significantly underestimate the RMR in male heavyweight endurance athletes but not in females. In athletes with a high fat-free mass, prediction equations might therefore not be applicable to estimate energy requirements. Instead, measurement of the resting energy expenditure or specific prediction equations might be needed for the individual heavyweight athlete.
Background: Athletes may differ in their resting metabolic rate (RMR) from the general population. However, to estimate the RMR in athletes, prediction equations that have not been validated in athletes are often used. The purpose of this study was therefore to verify the applicability of commonly used RMR predictions for use in athletes. Methods: The RMR was measured by indirect calorimetry in 17 highly trained rowers and canoeists of the German national teams (BMI 24 +/- 2 kg/m(2), fat-free mass 69 +/- 15 kg). In addition, the RMR was predicted using Cunningham (CUN) and Harris-Benedict (HB) equations. A two-way repeated measures ANOVA was calculated to test for differences between predicted and measured RMR (alpha = 0.05). The root mean square percentage error (RMSPE) was calculated and the Bland-Altman procedure was used to quantify the bias for each prediction. Results: Prediction equations significantly underestimated the RMR in males (p < 0.001). The RMSPE was calculated to be 18.4% (CUN) and 20.9% (HB) in the entire group. The bias was 133 kcal/24 h for CUN and 202 kcal/24 h for HB. Conclusions: Predictions significantly underestimate the RMR in male heavyweight endurance athletes but not in females. In athletes with a high fat-free mass, prediction equations might therefore not be applicable to estimate energy requirements. Instead, measurement of the resting energy expenditure or specific prediction equations might be needed for the individual heavyweight athlete.
BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly.
This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.
This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.