Refine
Has Fulltext
- no (37) (remove)
Year of publication
Document Type
- Article (37) (remove)
Is part of the Bibliography
- yes (37)
Keywords
- sonography (11)
- young athletes (5)
- Achilles tendon (3)
- advanced dynamic flow (3)
- neovascularization (3)
- neuromuscular (3)
- tendinopathy (3)
- training adaptation (3)
- ultrasound (3)
- Achilles and patellar tendon (2)
- Doppler ultrasound (2)
- SEMG-pattern (2)
- Tendinopathy (2)
- Ultrasonography (2)
- achilles tendinopathy (2)
- back pain (2)
- drop jump (2)
- epidemiology (2)
- hypoechogenicities (2)
- isokinetic (2)
- musculoskeletal (2)
- non-athletes (2)
- performance (2)
- pre-activity (2)
- reliability (2)
- reproducibility (2)
- trunk (2)
- ultrasonography (2)
- vascularization (2)
- Adaptation (1)
- Advanced Dynamic Flow (1)
- Ankle joint (1)
- Athletes (1)
- Athletic loading (1)
- Axillary lymph nodes (1)
- Breast ultrasound (1)
- Calorimetry (1)
- Cancer detection (1)
- Dietary supplements (1)
- ECG (1)
- Elasticity imaging (1)
- Electromyography (1)
- Elite athletes (1)
- Energy requirement (1)
- Fat-free mass (1)
- HI-RTE (1)
- Injury (1)
- Lymph node metastases (1)
- Minerals (1)
- Nutritional counseling (1)
- Overuse injury (1)
- Pain occurrence (1)
- Patella tendon (1)
- Prevalence (1)
- Real-time tissue elastography (1)
- Running gait (1)
- Sonoelastography (1)
- Tendon structure (1)
- Tolerable upper limits (1)
- Training volume (1)
- Ultrasound (1)
- VO2mdx (1)
- Vitamins (1)
- Young athletes (1)
- achilles and patellar tendon (1)
- adolescent athletes (1)
- ankle joint rotation (1)
- athlete (1)
- athletes (1)
- biomechanics (1)
- body composition (1)
- breast tissue (1)
- cardiopulmonary exercise testing (1)
- children (1)
- complaints (1)
- compliance (1)
- doppler ultrasound (1)
- dynamic (1)
- echocardiography (1)
- elasticity imaging (1)
- electromyography (1)
- elite athletes (1)
- gastrocnemius muscle (1)
- hyperechogenicities (1)
- hyperemia (1)
- inter-rater variability (1)
- intra- and inter-rater variability (1)
- intratendinous blood flow (1)
- kinematics (1)
- kinetics (1)
- lactate threshold (1)
- locomotion (1)
- metabolic device (1)
- muscle architecture (1)
- musculoskeletal ultrasound (1)
- neuromuscular control (1)
- overuse injuries (1)
- paediatric athlete (1)
- performance diagnostics (1)
- plantar fascia (1)
- pre-participation screening (1)
- principles of therapy (1)
- real-time tissue elastography (1)
- risk factors (1)
- runners (1)
- running gait (1)
- skinfold thickness (1)
- sonoelastography (1)
- sports (1)
- standard values (1)
- subcutaneous adipose tissue (1)
- sudden cardiac death (1)
- symptoms (1)
- tendinosis (1)
- tendon diameter (1)
- tendon thickness (1)
- training volume (1)
Objectives-The purpose of this study was to determine the dependence of breast tissue elasticity on the menstrual cycle of healthy volunteers by means of real-time sonoelastography.
Methods-Twenty-two healthy volunteers (aged 18-33 years) were examined once weekly during two consecutive menstrual cycles using sonoelastography. Group 1 (n = 10) was not taking hormonal medication; group 2 (n = 12) was taking oral contraceptives.
Results-The breast parenchyma appeared softer than the dermis and harder than the adipose tissue, and elasticity varied over the menstrual cycle and between groups. Group 1 (no hormone intake) showed continuously increasing elasticity with relatively soft breast parenchyma in the menstrual and follicular phases and harder parenchyma in the luteal phase (P = .012). Group 2 (oral contraceptives) showed no statistically significant changes in breast parenchymal elasticity according to sonoelastography. The parenchyma was generally softer in group 1 compared with group 2 throughout the menstrual cycle (P = .033). The dermis, the subcutaneous adipose tissue, and the pectoralis major muscle showed no changes in elasticity. Comparison of measurements made during the first and the second menstrual cycles showed similar patterns of elasticity in both groups.
Conclusions-Sonoelastography is a reproducible method that can be used to determine the dependence of breast parenchyma elasticity on the menstrual cycle and on the intake of hormonal contraceptives.
Subcutaneous adipose tissue (SAT) measurements with ultrasound have recently been introduced to assess body fat in elite athletes. However, appropriate protocols and data on various groups of athletes are missing. We investigated intra-rater reliability of SAT measurements using ultrasound in elite canoe athletes. 25 international level canoeists (18 male, 7 female; 23 +/- 4 years; 81 +/- 11 kg; 1.83 +/- 0.09 m; 20 +/- 3 training h/wk) were measured on 2 consecutive days. SAT was assessed with B-mode ultrasound at 8 sites (ISAK): triceps, subscapular, biceps, iliac crest, supraspinal, abdominal, front thigh, medial calf, and quantified using image analysis software. Data was analyzed descriptively (mean +/- SD, [range]). Coefficient of variation (CV %), intraclass correlation coefficient (ICC, 2.1) and absolute (LoA) and ratio limits of agreement (RLoA) were calculated for day-to-day reliability. Mean sum of SAT thickness was 30.0 +/- 19.4 mm [8.0, 80.1 mm], with 3.9 +/- 1.8 mm [1.2 mm subscapular, 8.0 mm abdominal] for individual sites. CV for the sum of sites was 4.7 %, ICC 0.99, LoA 1.7 +/- 3.6 mm, RLoA 0.940 (*/divided by 1.155). Measuring SAT with ultrasound has proved to have excellent day-to-day reliability in elite canoe athletes. Recommendations for standardization of the method will further increase accuracy and reproducibility.
BACKGROUND: Reproducible measurements of tendon structural properties are a prerequisite for accurate diagnosis of tendon disorders and for determination of their mechanical properties. Despite the widely used application of Ultrasonography (US) in musculoskeletal assessment, its operator dependency and lack of standardization influences the consistency of the measurement.
OBJECTIVE: To evaluate the intra-rater reproducibility of a standardized US method assessing the structural properties of the Achilles tendon (AT).
METHODS: Sixteen asymptomatic participants were positioned prone on an isokinetic dynamometer with the knee extended and ankle at 90. flexion. US was used to assess AT-length, cross-sectional area (CSA), and AT-elongation during isometric plantarflexion contraction. The intra-rater reproducibility was assessed by ICC (2.1), Test-Retest Variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]), and Standard-Error of Measurement (SEM).
RESULTS: Measurements of AT-length demonstrated an ICC of 0.93, TRV of 4.5 +/- 3.9%, Bias +/- LoA of -2.8 +/- 25.0 mm and SEM of 6.6 mm. AT-CSA showed an ICC of 0.79, TRV of 8.7 +/- 9.6%, Bias +/- LoA of 1.7 +/- 19.4 mm(2) and SEM of 5.3 mm(2). AT-elongation revealed an ICC of 0.92, TRV of 12.9 +/- 8.9%, Bias +/- LoA of 0.3 +/- 5.7 mm and SEM of 1.5 mm.
CONCLUSIONS: The presented methodology allows a reproducible assessment of Achilles tendon structural properties when performed by a single rater.
In the context of back pain, great emphasis has been placed on the importance of trunk stability, especially in situations requiring compensation of repetitive, intense loading induced during high-performance activities, e.g., jumping or landing. This study aims to evaluate trunk muscle activity during drop jump in adolescent athletes with back pain (BP) compared to athletes without back pain (NBP). Eleven adolescent athletes suffering back pain (BP: m/f: n = 4/7; 15.9 ± 1.3 y; 176 ± 11 cm; 68 ± 11 kg; 12.4 ± 10.5 h/we training) and 11 matched athletes without back pain (NBP: m/f: n = 4/7; 15.5 ± 1.3 y; 174 ± 7 cm; 67 ± 8 kg; 14.9 ± 9.5 h/we training) were evaluated. Subjects conducted 3 drop jumps onto a force plate (ground reaction force). Bilateral 12-lead SEMG (surface Electromyography) was applied to assess trunk muscle activity. Ground contact time [ms], maximum vertical jump force [N], jump time [ms] and the jump performance index [m/s] were calculated for drop jumps. SEMG amplitudes (RMS: root mean square [%]) for all 12 single muscles were normalized to MIVC (maximum isometric voluntary contraction) and analyzed in 4 time windows (100 ms pre- and 200 ms post-initial ground contact, 100 ms pre- and 200 ms post-landing) as outcome variables. In addition, muscles were grouped and analyzed in ventral and dorsal muscles, as well as straight and transverse trunk muscles. Drop jump ground reaction force variables did not differ between NBP and BP (p > 0.05). Mm obliquus externus and internus abdominis presented higher SEMG amplitudes (1.3–1.9-fold) for BP (p < 0.05). Mm rectus abdominis, erector spinae thoracic/lumbar and latissimus dorsi did not differ (p > 0.05). The muscle group analysis over the whole jumping cycle showed statistically significantly higher SEMG amplitudes for BP in the ventral (p = 0.031) and transverse muscles (p = 0.020) compared to NBP. Higher activity of transverse, but not straight, trunk muscles might indicate a specific compensation strategy to support trunk stability in athletes with back pain during drop jumps. Therefore, exercises favoring the transverse trunk muscles could be recommended for back pain treatment.
In the context of back pain, great emphasis has been placed on the importance of trunk stability, especially in situations requiring compensation of repetitive, intense loading induced during high-performance activities, e.g., jumping or landing. This study aims to evaluate trunk muscle activity during drop jump in adolescent athletes with back pain (BP) compared to athletes without back pain (NBP). Eleven adolescent athletes suffering back pain (BP: m/f: n = 4/7; 15.9 +/- 1.3 y; 176 +/- 11 cm; 68 +/- 11 kg; 12.4 +/- 10.5 h/we training) and 11 matched athletes without back pain (NBP: m/f: n = 4/7; 15.5 +/- 1.3 y; 174 +/- 7 cm; 67 +/- 8 kg; 14.9 +/- 9.5 h/we training) were evaluated. Subjects conducted 3 drop jumps onto a force plate (ground reaction force). Bilateral 12-lead SEMG (surface Electromyography) was applied to assess trunk muscle activity. Ground contact time [ms], maximum vertical jump force [N], jump time [ms] and the jump performance index [m/s] were calculated for drop jumps. SEMG amplitudes (RMS: root mean square [%]) for all 12 single muscles were normalized toMIVC (maximum isometric voluntary contraction) and analyzed in 4 time windows (100 ms pre- and 200 ms post-initial ground contact, 100 ms pre- and 200 ms post-landing) as outcome variables. In addition, muscles were grouped and analyzed in ventral and dorsal muscles, as well as straight and transverse trunk muscles. Drop jump ground reaction force variables did not differ between NBP and BP (p > 0.05). Mm obliquus externus and internus abdominis presented higher SEMG amplitudes (1.3-1.9-fold) for BP (p < 0.05). Mm rectus abdominis, erector spinae thoracic/lumbar and latissimus dorsi did not differ (p > 0.05). The muscle group analysis over the whole jumping cycle showed statistically significantly higher SEMG amplitudes for BP in the ventral (p = 0.031) and transverse muscles (p = 0.020) compared to NBP. Higher activity of transverse, but not straight, trunk muscles might indicate a specific compensation strategy to support trunk stability in athletes with back pain during drop jumps. Therefore, exercises favoring the transverse trunk muscles could be recommended for back pain treatment.
Tendon adaptation due to mechanical loading is controversially discussed. However, data concerning the development of tendon thickness in adolescent athletes is sparse. The purpose of this study was to examine possible differences in Achilles (AT) and patellar tendon (PT) thickness in adolescent athletes while considering age, gender and sport-specific loading. In 500 adolescent competitive athletes of 16 different sports and 40 recreational controls both ATs and PTs were sonographically measured. Subjects were divided into 2 age groups (< 13; ≥ 13 years) and 6 sport type categories (ball, combat, and water sports, combined disciplines, cycling, controls). In addition, 3 risk groups (low, moderate, high) were created according to the athlete’s risk of developing tendinopathy. AT and PT thickness did not significantly differ between age groups (AT/PT:<13: 5.4±0.7 mm/3.6±0.5 mm;≥13: 5.3±0.7 mm/3.6±0.5 mm). In both age groups males presented higher tendon thickness than females (p<0.001). AT thickness was highest in ball sports/cyclists and lowest in controls (p≤0.002). PT thickness was greatest in water sports and lowest in controls (p=0.02). High risk athletes presented slightly higher AT thickness compared to the low risk group (p=0.03). Increased AT and PT thickness in certain sport types compared to controls supports the hypothesis of structural tendon adaptation due to sport-specific loading.
Tendinopathies are frequently the cause of chronic, load-dependent complaints of the lower extremity. Commonly, the large tendons of the ankle and knee joints are affected, especially the Achilles and patellar tendons. Repeated overuse in sports and/or daily activities is assumed as the aetiology. Besides the clinical examination including a comprehensive anamnesis of pain and training/loading, sonographic imaging has a high training/loading relevance for the diagnosis of tendon pathologies of the lower extremity. Training concepts are considered in first line as the treatment of choice. A combination with physical therapy interventions can be useful. In cases of a more severe pathology and long-standing complaints multimodal therapeutic options should be employed. The use of surgical treatment procedures should only be taken into account in case of failed response to conservative treatment.
Background: Athletes may differ in their resting metabolic rate (RMR) from the general population. However, to estimate the RMR in athletes, prediction equations that have not been validated in athletes are often used. The purpose of this study was therefore to verify the applicability of commonly used RMR predictions for use in athletes. Methods: The RMR was measured by indirect calorimetry in 17 highly trained rowers and canoeists of the German national teams (BMI 24 +/- 2 kg/m(2), fat-free mass 69 +/- 15 kg). In addition, the RMR was predicted using Cunningham (CUN) and Harris-Benedict (HB) equations. A two-way repeated measures ANOVA was calculated to test for differences between predicted and measured RMR (alpha = 0.05). The root mean square percentage error (RMSPE) was calculated and the Bland-Altman procedure was used to quantify the bias for each prediction. Results: Prediction equations significantly underestimated the RMR in males (p < 0.001). The RMSPE was calculated to be 18.4% (CUN) and 20.9% (HB) in the entire group. The bias was 133 kcal/24 h for CUN and 202 kcal/24 h for HB. Conclusions: Predictions significantly underestimate the RMR in male heavyweight endurance athletes but not in females. In athletes with a high fat-free mass, prediction equations might therefore not be applicable to estimate energy requirements. Instead, measurement of the resting energy expenditure or specific prediction equations might be needed for the individual heavyweight athlete.
BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly.
This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.