The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 5 of 9
Back to Result List

Intra- and interrater variability of sonographic investigations of patella and achilles tendons

  • Background: Clinical examinations of tendon disorders routinely include ultrasound examinations, despite the fact that availability of data concerning validity criteria of these measurements are limited. The present study therefore aims to evaluate the reliability of measurements of Achilles- and Patella tendon diameter and in the detection of structural adaptations. Materials and Methods: In 14 healthy, recreationally active subjects both asymptomatic Achilles (AT) and patella tendons (PT) were measured twice by two examiners in a test-retest design. Besides the detection of anteroposterior (a.p.-) and mediolateral (m.l.-) diameters, areas of hypoechogenicity and neovascularisation were registered. Data were analysed descriptively with calculation of test-retest variability (TRV), intraclass-correlation coefficient (ICC) and Bland and Altman's plots with bias and 95% limits of agreement (LOA). Results: Intra- and interrater differences of AT- and PT-a.p.-diameter varied from 0.2 - 1.2 mm, those of AT- and PT-m.l-diameter fromBackground: Clinical examinations of tendon disorders routinely include ultrasound examinations, despite the fact that availability of data concerning validity criteria of these measurements are limited. The present study therefore aims to evaluate the reliability of measurements of Achilles- and Patella tendon diameter and in the detection of structural adaptations. Materials and Methods: In 14 healthy, recreationally active subjects both asymptomatic Achilles (AT) and patella tendons (PT) were measured twice by two examiners in a test-retest design. Besides the detection of anteroposterior (a.p.-) and mediolateral (m.l.-) diameters, areas of hypoechogenicity and neovascularisation were registered. Data were analysed descriptively with calculation of test-retest variability (TRV), intraclass-correlation coefficient (ICC) and Bland and Altman's plots with bias and 95% limits of agreement (LOA). Results: Intra- and interrater differences of AT- and PT-a.p.-diameter varied from 0.2 - 1.2 mm, those of AT- and PT-m.l-diameter from 0.7-5.1 mm. Areas of hypoechogenicity were visible in 24% of the tendons, while 15% showed neovascularisations. Intrarater AT-a.p.-diameters showed sparse deviations (TRV 4.5-7.4%; ICC 0.60-0.84; bias -0.05-0.07 mm; LOA-0.6-0.5 to -1.1 - 1.0 mm), while interrater AT- and PT-m.l.-diameters were highly variable (TRV 13.7-19.7%; ICC 0.11-0.20; bias -1.4-4.3 mm; LOA-5.5-2.7 to -10.5 - 1.9 mm). Conclusion: Our results suggest that the measurement of AT- and PT-a.p.-diameters is a reliable parameter. In contrast, reproducibility of AT- and PT-m.l.-diameters is questionable. The study corroborates the presence of hypoechogenicity and neovascularisation in asymptomatic tendons.show moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:Michael CasselORCiDGND, Steffen MüllerGND, Anja CarlsohnORCiDGND, Heiner BaurORCiDGND, N. Jerusel, Frank MayerORCiDGND
DOI:https://doi.org/10.1055/s-0031-1281839
ISSN:0932-0555
Title of parent work (German):Sportverletzung, Sportschaden : Grundlagen, Prävention, Rehabilitation
Publisher:Thieme
Place of publishing:Stuttgart
Publication type:Article
Language:German
Year of first publication:2012
Publication year:2012
Release date:2017/03/26
Tag:Achilles tendon; Patella tendon; intra- and inter-rater variability; tendon diameter; ultrasound
Volume:26
Issue:1
Number of pages:6
First page:21
Last Page:26
Organizational units:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Sport- und Gesundheitswissenschaften
Peer review:Referiert
Institution name at the time of the publication:Humanwissenschaftliche Fakultät / Institut für Sportmedizin und Prävention
Accept ✔
This website uses technically necessary session cookies. By continuing to use the website, you agree to this. You can find our privacy policy here.