Reliability of the active knee joint position sense test and influence of limb dominance and sex

  • The output of a sensorimotor performance can be measured with the joint position sense (JPS) test. However, investigations of leg dominance, sex and quality measures on this test are limited. Therefore, these potential influencing factors as well as reliability and consistency measures were evaluated for angular reproduction performance and neuromuscular activity during the active knee JPS test in healthy participants. Twenty healthy participants (10 males; 10 females; age 29 +/- 8 years; height 165 +/- 39 cm; body mass 69 +/- 13 kg) performed a seated knee JPS test with a target angle of 50 degrees. Measurements were conducted in two sessions separated by two weeks and consisted of two blocks of continuous angular reproduction (three minutes each block). The difference between reproduced and target angle was identified as angular error measured by an electrogoniometer. During reproduction, the neuromuscular activity of the quadriceps muscle was assessed by surface electromyography. Neuromuscular activity was normalized to submaximalThe output of a sensorimotor performance can be measured with the joint position sense (JPS) test. However, investigations of leg dominance, sex and quality measures on this test are limited. Therefore, these potential influencing factors as well as reliability and consistency measures were evaluated for angular reproduction performance and neuromuscular activity during the active knee JPS test in healthy participants. Twenty healthy participants (10 males; 10 females; age 29 +/- 8 years; height 165 +/- 39 cm; body mass 69 +/- 13 kg) performed a seated knee JPS test with a target angle of 50 degrees. Measurements were conducted in two sessions separated by two weeks and consisted of two blocks of continuous angular reproduction (three minutes each block). The difference between reproduced and target angle was identified as angular error measured by an electrogoniometer. During reproduction, the neuromuscular activity of the quadriceps muscle was assessed by surface electromyography. Neuromuscular activity was normalized to submaximal voluntary contraction (subMVC) and displayed per muscle and movement phase. Differences between leg dominance and sex were calculated using Friedman-test (alpha = 0.05). Reliability measures including intraclass correlation coefficient (ICC), Bland-Altman analysis (bias +/- limits of agreement (LoA)) and minimal detectable change (MDC) were analysed. No significant differences between leg dominance and sex were found in angular error and neuromuscular activity. Angular error demonstrated inter-session ICC scores of 0.424 with a bias of 2.4 degrees (+/- 2.4 degrees LoA) as well as MDC of 6.8 degrees and moderate intra-session ICC (0.723) with a bias of 1.4 degrees (+/- 1.65 degrees LoA) as well as MDC of 4.7 degrees. Neuromuscular activity for all muscles and movement phases illustrated inter-session ICC ranging from 0.432 to 0.809 with biases between - 2.5 and 13.6% subMVC and MDC from 13.4 to 63.9% subMVC. Intra-session ICC ranged from 0.705 to 0.987 with biases of - 7.7 to 2.4% subMVC and MDC of 2.7 to 46.5% subMVC. Leg dominance and sex seem not to influence angular reproduction performance and neuromuscular activity. Poor to excellent relative reliability paired with an acceptable consistency confirm findings of previous studies. Comparisons to pathological populations should be conducted with caution.show moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:Aglaja BuschORCiD, Christian BangerterORCiD, Frank MayerORCiDGND, Heiner BaurORCiDGND
DOI:https://doi.org/10.1038/s41598-022-26932-2
ISSN:2045-2322
Pubmed ID:https://pubmed.ncbi.nlm.nih.gov/36599861
Title of parent work (English):Scientific reports
Publisher:Macmillan Publishers Limited, part of Springer Nature
Place of publishing:London
Publication type:Article
Language:English
Date of first publication:2023/01/04
Publication year:2023
Release date:2024/06/20
Volume:13
Article number:152
Number of pages:10
Organizational units:Weitere Einrichtungen / Hochschulambulanz
DDC classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Peer review:Referiert
Publishing method:Open Access / Gold Open-Access
DOAJ gelistet
License (German):License LogoCC-BY - Namensnennung 4.0 International