TY - JOUR A1 - Aloui, Ali A1 - Tayech, Amel A1 - Arbi Mejri, Mohamed A1 - Makhlouf, Issam A1 - Clark, Cain C. T. A1 - Granacher, Urs A1 - Zouhal, Hassane A1 - Ben Abderrahman, Abderraouf T1 - Reliability and Validity of a New Taekwondo-Specific Change-of-Direction Speed Test With Striking Techniques in Elite Taekwondo Athletes: A Pilot Study JF - Frontiers in Physiology N2 - The purpose of this study was to examine the test-retest reliability, and convergent and discriminative validity of a new taekwondo-specific change-of-direction (COD) speed test with striking techniques (TST) in elite taekwondo athletes. Twenty (10 males and 10 females) elite (athletes who compete at national level) and top-elite (athletes who compete at national and international level) taekwondo athletes with an average training background of 8.9 ± 1.3 years of systematic taekwondo training participated in this study. During the two-week test-retest period, various generic performance tests measuring COD speed, balance, speed, and jump performance were carried out during the first week and as a retest during the second week. Three TST trials were conducted with each athlete and the best trial was used for further analyses. The relevant performance measure derived from the TST was the time with striking penalty (TST-TSP). TST-TSP performances amounted to 10.57 ± 1.08 s for males and 11.74 ± 1.34 s for females. The reliability analysis of the TST performance was conducted after logarithmic transformation, in order to address the problem of heteroscedasticity. In both groups, the TST demonstrated a high relative test-retest reliability (intraclass correlation coefficients and 90% compatibility limits were 0.80 and 0.47 to 0.93, respectively). For absolute reliability, the TST’s typical error of measurement (TEM), 90% compatibility limits, and magnitudes were 4.6%, 3.4 to 7.7, for males, and 5.4%, 3.9 to 9.0, for females. The homogeneous sample of taekwondo athletes meant that the TST’s TEM exceeded the usual smallest important change (SIC) with 0.2 effect size in the two groups. The new test showed mostly very large correlations with linear sprint speed (r = 0.71 to 0.85) and dynamic balance (r = −0.71 and −0.74), large correlations with COD speed (r = 0.57 to 0.60) and vertical jump performance (r = −0.50 to −0.65), and moderate correlations with horizontal jump performance (r = −0.34 to −0.45) and static balance (r = −0.39 to −0.44). Top-elite athletes showed better TST performances than elite counterparts. Receiver operating characteristic analysis indicated that the TST effectively discriminated between top-elite and elite taekwondo athletes. In conclusion, the TST is a valid, and sensitive test to evaluate the COD speed with taekwondo specific skills, and reliable when considering ICC and TEM. Although the usefulness of the TST is questioned to detect small performance changes in the present population, the TST can detect moderate changes in taekwondo-specific COD speed. KW - taekwondo-specific testing KW - sport-specific performance KW - striking combat sports KW - sensitivity KW - taekwondo electronic scoring system Y1 - 2022 U6 - https://doi.org/10.3389/fphys.2022.774546 SN - 1664-042X VL - 13 SP - 1 EP - 15 PB - Frontiers CY - Lausanne, Schweiz ER - TY - GEN A1 - Albert, Justin Amadeus A1 - Owolabi, Victor A1 - Gebel, Arnd A1 - Brahms, Clemens Markus A1 - Granacher, Urs A1 - Arnrich, Bert T1 - Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard BT - A Pilot Study T2 - Postprints der Universität Potsdam : Reihe der Digital Engineering Fakultät N2 - Gait analysis is an important tool for the early detection of neurological diseases and for the assessment of risk of falling in elderly people. The availability of low-cost camera hardware on the market today and recent advances in Machine Learning enable a wide range of clinical and health-related applications, such as patient monitoring or exercise recognition at home. In this study, we evaluated the motion tracking performance of the latest generation of the Microsoft Kinect camera, Azure Kinect, compared to its predecessor Kinect v2 in terms of treadmill walking using a gold standard Vicon multi-camera motion capturing system and the 39 marker Plug-in Gait model. Five young and healthy subjects walked on a treadmill at three different velocities while data were recorded simultaneously with all three camera systems. An easy-to-administer camera calibration method developed here was used to spatially align the 3D skeleton data from both Kinect cameras and the Vicon system. With this calibration, the spatial agreement of joint positions between the two Kinect cameras and the reference system was evaluated. In addition, we compared the accuracy of certain spatio-temporal gait parameters, i.e., step length, step time, step width, and stride time calculated from the Kinect data, with the gold standard system. Our results showed that the improved hardware and the motion tracking algorithm of the Azure Kinect camera led to a significantly higher accuracy of the spatial gait parameters than the predecessor Kinect v2, while no significant differences were found between the temporal parameters. Furthermore, we explain in detail how this experimental setup could be used to continuously monitor the progress during gait rehabilitation in older people. T3 - Zweitveröffentlichungen der Universität Potsdam : Reihe der Digital Engineering Fakultät - 3 KW - motion capture KW - evaluation KW - human motion KW - RGB-D cameras KW - digital health Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-484130 IS - 3 ER - TY - JOUR A1 - Albert, Justin Amadeus A1 - Owolabi, Victor A1 - Gebel, Arnd A1 - Brahms, Clemens Markus A1 - Granacher, Urs A1 - Arnrich, Bert T1 - Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard BT - A Pilot Study JF - Sensors N2 - Gait analysis is an important tool for the early detection of neurological diseases and for the assessment of risk of falling in elderly people. The availability of low-cost camera hardware on the market today and recent advances in Machine Learning enable a wide range of clinical and health-related applications, such as patient monitoring or exercise recognition at home. In this study, we evaluated the motion tracking performance of the latest generation of the Microsoft Kinect camera, Azure Kinect, compared to its predecessor Kinect v2 in terms of treadmill walking using a gold standard Vicon multi-camera motion capturing system and the 39 marker Plug-in Gait model. Five young and healthy subjects walked on a treadmill at three different velocities while data were recorded simultaneously with all three camera systems. An easy-to-administer camera calibration method developed here was used to spatially align the 3D skeleton data from both Kinect cameras and the Vicon system. With this calibration, the spatial agreement of joint positions between the two Kinect cameras and the reference system was evaluated. In addition, we compared the accuracy of certain spatio-temporal gait parameters, i.e., step length, step time, step width, and stride time calculated from the Kinect data, with the gold standard system. Our results showed that the improved hardware and the motion tracking algorithm of the Azure Kinect camera led to a significantly higher accuracy of the spatial gait parameters than the predecessor Kinect v2, while no significant differences were found between the temporal parameters. Furthermore, we explain in detail how this experimental setup could be used to continuously monitor the progress during gait rehabilitation in older people. KW - motion capture KW - evaluation KW - human motion KW - RGB-D cameras KW - digital health Y1 - 2020 U6 - https://doi.org/10.3390/s20185104 SN - 1424-8220 VL - 20 IS - 18 PB - MDPI CY - Basel ER - TY - JOUR A1 - Ahmadi, Hamid A1 - Herat, Nehara A1 - Alizadeh, Shahab A1 - Button, Duane C. A1 - Granacher, Urs A1 - Behm, David G. T1 - Effect of an inverted seated position with upper arm blood flow restriction on measures of elbow flexors neuromuscular performance JF - PLOS ONE / Public Library of Science N2 - Purpose The objective of the investigation was to determine the concomitant effects of upper arm blood flow restriction (BFR) and inversion on elbow flexors neuromuscular responses. Methods Randomly allocated, 13 volunteers performed four conditions in a within-subject design: rest (control, 1-min upright position without BFR), control (1-min upright with BFR), 1-min inverted (without BFR), and 1-min inverted with BFR. Evoked and voluntary contractile properties, before, during and after a 30-s maximum voluntary contraction (MVC) exercise intervention were examined as well as pain scale. Results Inversion induced significant pre-exercise intervention decreases in elbow flexors MVC (21.1%, Z2p = 0.48, p = 0.02) and resting evoked twitch forces (29.4%, Z2p = 0.34, p = 0.03). The 30-s MVC induced significantly greater pre- to post-test decreases in potentiated twitch force (Z2p = 0.61, p = 0.0009) during inversion (75%) than upright (65.3%) conditions. Overall, BFR decreased MVC force 4.8% (Z2p = 0.37, p = 0.05). For upright position, BFR induced 21.0% reductions in M-wave amplitude (Z2p = 0.44, p = 0.04). There were no significant differences for electromyographic activity or voluntary activation as measured with the interpolated twitch technique. For all conditions, there was a significant increase in pain scale between the 40-60 s intervals and post-30-s MVC (upright< inversion, and without BFR< BFR). Conclusion The concomitant application of inversion with elbow flexors BFR only amplified neuromuscular performance impairments to a small degree. Individuals who execute forceful contractions when inverted or with BFR should be cognizant that force output may be impaired. Y1 - 2021 U6 - https://doi.org/10.1371/journal.pone.0245311 SN - 1932-6203 VL - 16 IS - 5 PB - PLoS CY - San Fransisco ER -