TY - JOUR A1 - Trinh, Christopher Q. A1 - Ellis, Simon C. A1 - Bland-Hawthorn, Joss A1 - Lawrence, Jon S. A1 - Horton, Anthony J. A1 - Leon-Saval, Sergio G. A1 - Shortridge, Keith A1 - Bryant, Julia A1 - Case, Scott A1 - Colless, Matthew A1 - Couch, Warrick A1 - Freeman, Kenneth A1 - Löhmannsröben, Hans-Gerd A1 - Gers, Luke A1 - Glazebrook, Karl A1 - Haynes, Roger A1 - Lee, Steve A1 - O'Byrne, John A1 - Miziarski, Stan A1 - Roth, Martin M. A1 - Schmidt, Brian A1 - Tinney, Christopher G. A1 - Zheng, Jessica T1 - Gnosis - the first instrument to use fiber bragg gratings for OH suppression JF - The astronomical journal N2 - The near-infrared is an important part of the spectrum in astronomy, especially in cosmology because the light from objects in the early universe is redshifted to these wavelengths. However, deep near-infrared observations are extremely difficult to make from ground-based telescopes due to the bright background from the atmosphere. Nearly all of this background comes from the bright and narrow emission lines of atmospheric hydroxyl (OH) molecules. The atmospheric background cannot be easily removed from data because the brightness fluctuates unpredictably on short timescales. The sensitivity of ground-based optical astronomy far exceeds that of near-infrared astronomy because of this long-standing problem. GNOSIS is a prototype astrophotonic instrument that utilizes "OH suppression fibers" consisting of fiber Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47 and 1.7 mu m. GNOSIS was commissioned at the 3.9 m Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibers, but may be potentially used with any telescope and spectrograph combination. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion and in a manner that depends purely on wavelength. We present the instrument design and report the results of laboratory and on-sky tests from commissioning. While these tests demonstrated high throughput (approximate to 60%) and excellent suppression of the skylines by the OH suppression fibers, surprisingly GNOSIS produced no significant reduction in the interline background and the sensitivity of GNOSIS+IRIS2 is about the same as IRIS2. It is unclear whether the lack of reduction in the interline background is due to physical sources or systematic errors as the observations are detector noise dominated. OH suppression fibers could potentially impact ground-based astronomy at the level of adaptive optics or greater. However, until a clear reduction in the interline background and the corresponding increasing in sensitivity is demonstrated optimized OH suppression fibers paired with a fiber-fed spectrograph will at least provide a real benefit at low resolving powers. KW - atmospheric effects KW - infrared: diffuse background KW - instrumentation: miscellaneous Y1 - 2013 U6 - https://doi.org/10.1088/0004-6256/145/2/51 SN - 0004-6256 VL - 145 IS - 2 PB - IOP Publ. Ltd. CY - Bristol ER - TY - JOUR A1 - Roth, Martin M. A1 - Löhmannsröben, Hans-Gerd A1 - Kelz, A. A1 - Kumke, Michael Uwe T1 - innoFSPEC : fiber optical spectroscopy and sensing Y1 - 2008 SN - 978-0-819-47228-1 ER - TY - JOUR A1 - Beitz, Toralf A1 - Laudien, Robert A1 - Löhmannsröben, Hans-Gerd A1 - Kallies, Bernd T1 - Ion mobility spectrometric investigation of aromatic cations in the gas phase N2 - In this work, ion mobility (IM) spectra of more than 50 aromatic compounds were recorded with a laser-based IM spectrometer at atmospheric pressure. IM spectra of PAH in the laser desorption experiment show a high complexity resulting from the occurrence of monomeric, dimeric, and oligomeric cluster ions. The mobilities of all compounds were determined in helium as drift gas. This allows the calculation of the diffusion cross sections (Omega(calc)) on the basis of the exact hard sphere scattering model and their comparison with the experimentally determined diffusion cross sections (Omega(exp)). Extended Omega(exp)/Omega(calc) and Omega(exp/)mass correlations were performed in order to gain insight into conformational properties of cationic alkyl benzenes and internal rotation of phenyl rings in aromatic ions. This is demonstrated with some examples, such as the evaluation of the dihedral angle of the ions of 9,10- diphenylanthracene, o- and m-terphenyl, and 1,2,3- and 1,3,5-triphenylbenzene. Furthermore, sandwich and T-structures of dimeric PAH cations are discussed. The analysis was extended to oligomeric ions with up to nine monomer units. Experimental evidence is presented suggesting the formation of pi-stacks with a transition toward modified pi-stacks with increasing cluster size. The distance between monomeric units in dimeric and oligomeric ions was obtained Y1 - 2006 UR - http://pubs.acs.org/journal/jpcafh U6 - https://doi.org/10.1021/Jp055335n SN - 1089-5639 ER - TY - JOUR A1 - Hildebrandt, Niko A1 - Charbonniere, Loïc J. A1 - Beck, Michael A1 - Ziessel, Raymond F. A1 - Löhmannsröben, Hans-Gerd T1 - Quantum dots as efficient energy acceptors in a time-resolved fluoroimmunoassay Y1 - 2005 SN - 1433-7851 ER - TY - JOUR A1 - Löhmannsröben, Hans-Gerd T1 - Laser-induced fluorescence (LIF) spectroscopy and laser-based ion mobility (IM) spectrometry for in-situ analysis of contaminated soils Y1 - 2005 ER - TY - JOUR A1 - Löhmannsröben, Hans-Gerd A1 - Lau, Steffen T1 - Isotope selectivity in environmental monitoring : NIR diode laser spectroscopy for isotope-selective sensing of soil-respired carbon dioxide Y1 - 2005 ER - TY - JOUR A1 - Lemke, Matthias A1 - Fernandez-Trujillo, R. A1 - Löhmannsröben, Hans-Gerd T1 - In-situ LIF analysis of biological and petroleum-based hydraulic oils on soil N2 - Absorption and fluorescence properties of 4 hydraulic oils ( 3 biological and 1 petroleum-based) were investigated. In-situ LIF (laser-induced fluorescence) analysis of the oils on a brown sandy loam soil was performed. With calibration, quantitative detection was achieved. Estimated limits of detection were below ca. 500 mg/kg for the petroleum-based oil and ca. 2000 mg/kg for one biological oil. A semi-quantitative classification scheme is proposed for monitoring of the biological oils. This approach was applied to investigate the migration of a biological oil in soil- containing compartments, namely a soil column and a soil bed Y1 - 2005 SN - 1424-8220 ER - TY - JOUR A1 - Engelhard, Sonja A1 - Löhmannsröben, Hans-Gerd A1 - Schael, Frank T1 - Quantifying ethanol content of beer using interpretive near-infrared spectroscopy N2 - On the basis of absorption measurements in the near-infrared (NIR) spectral range, a new method for the quantification of the ethanol content of beer is presented. Instead of the multivariate calibration models most commonly employed in NIR spectroscopic works, we use interpretive difference spectroscopy: Two wavelengths are selected according to the assignment of the absorption bands of the main substances of content of beer in the NIR region, and the difference between the absorbances at these wavelengths is used for ethanol quantification. Absorption spectra of the dominating beer ingredients are discussed and the calibration procedure with ethanol/water mixtures is shown. Robustness against the carbohydrate content of beer samples was demonstrated by analyzing solutions of ethanol and maltose in water. Validation of the method was performed with various beer samples with an ethanol concentration range between 0.5 and 7.7 vol %. The pertinent advantage of the procedure developed in this work is the indication that the results are independent from seasonal variations of the ingredients, which is of high interest for products with natural ingredients such as beer Y1 - 2004 SN - 0003-7028 ER - TY - JOUR A1 - Dosche, Carsten A1 - Kumke, Michael Uwe A1 - Löhmannsröben, Hans-Gerd A1 - Ariese, Freek A1 - Bader, Arjen N. A1 - Gooijer, Cees A1 - Miljanic, Ognjen S. A1 - Iwamoto, M. A1 - Vollhardt, K. Peter C. A1 - Puchta, Ralph A1 - Hommes, N. J. R. V. T1 - Deuteration effects on the vibronic structure of the fluorescence spectra and the internal conversion rates of triangular [4]phenylene N2 - Deuteration effects on the vibronic structure of the emission and excitation spectra of triangular [ 4] phenylene (D-3h [4]phenylene) were studied using laser-excited Shpol'skii spectroscopy (LESS) in an octane matrix at 4.2 K. For correct assignment of the vibrational modes, the experimental results were compared with calculated frequencies (B3LYP/6-31G*). CH vibrations were identified by their characteristic isotopic shifts in the spectra of deuterated triangular [4]phenylenes. Two CC stretching modes, at 100 cm(-1) and 1176 cm(-1), suitable as probes for bond strength changes in the excited state, were identified. The isotope effect on the internal conversion rates of triangular [4] phenylene was evaluated from measurements of temperature dependent lifetime. Isotope dependency and the magnitude of the internal conversion rates indicate that internal conversion in triangular [4] phenylene is most likely induced by CH vibrations. The results obtained by LESS and lifetime measurements were compared with PM3 PECI calculations of the excited state structure. The theoretical results and the relation between ground and excited state vibration energies of the 1176 cm(-1) probe vibration indicate a reduction of bond alternation of the central cyclohexatriene ring in the excited state Y1 - 2004 SN - 1463-9076 ER - TY - JOUR A1 - Horner, G. A1 - Lau, Steffen A1 - Kantor, Z. A1 - Löhmannsröben, Hans-Gerd T1 - Isotope selective analysis of CO2 with tunable diode laser (TDL) spectroscopy in the NIR N2 - The performance of a home-built tunable diode laser (TDL) spectrometer, aimed at multi-line detection of carbon dioxide, has been evaluated and optimized. In the regime of the (3001)(III) <-- (000) band of (CO2)-C-12 around 1.6 mum, the dominating isotope species (CO2)-C-12, (CO2)-C-13, and (COO)-C-12-O-18-O-16 were detected simultaneously without interference by water vapor. Detection limits in the range of few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. High sensitivity in conjunction with high precision-typically +/-1% and +/-6% for 3% and 0.7% of CO2, respectively-renders this experimental approach a promising analytical concept for isotope-ratio determination of carbon dioxide in soil and breath gas. For a moderate (CO2)-C-12 line, the pressure dependence of the line profile was characterized in detail, to account for pressure effects on sensitive measurements Y1 - 2004 SN - 0003-2654 ER - TY - JOUR A1 - Brinkmann, Pia A1 - Köllner, Nicole A1 - Merk, Sven A1 - Beitz, Toralf A1 - Altenberger, Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Comparison of handheld and echelle spectrometer to assess copper in ores by means of laser-induced breakdown spectroscopy (LIBS) JF - Minerals N2 - Its properties make copper one of the world’s most important functional metals. Numerous megatrends are increasing the demand for copper. This requires the prospection and exploration of new deposits, as well as the monitoring of copper quality in the various production steps. A promising technique to perform these tasks is Laser Induced Breakdown Spectroscopy (LIBS). Its unique feature, among others, is the ability to measure on site without sample collection and preparation. In this work, copper-bearing minerals from two different deposits are studied. The first set of field samples come from a volcanogenic massive sulfide (VMS) deposit, the second part from a stratiform sedimentary copper (SSC) deposit. Different approaches are used to analyze the data. First, univariate regression (UVR) is used. However, due to the strong influence of matrix effects, this is not suitable for the quantitative analysis of copper grades. Second, the multivariate method of partial least squares regression (PLSR) is used, which is more suitable for quantification. In addition, the effects of the surrounding matrices on the LIBS data are characterized by principal component analysis (PCA), alternative regression methods to PLSR are tested and the PLSR calibration is validated using field samples. KW - LIBS KW - copper-bearing minerals KW - UVR KW - PCA KW - PLSR Y1 - 2023 U6 - https://doi.org/10.3390/min13010113 SN - 2075-163X VL - 13 IS - 1 PB - MDPI CY - Basel ER - TY - JOUR A1 - Villatoro, José Andrés A1 - Weber, M. A1 - Zühlke, Martin A1 - Lehmann, A. A1 - Zenichowski, Karl A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Kreuzer, O. T1 - Structural characterization of synthetic peptides using electrospray ion mobility spectrometry and molecular dynamics simulations JF - International Journal of Mass Spectrometry N2 - Electrospray ionization-ion mobility spectrometry was employed for the determination of collision cross sections (CCS) of 25 synthetically produced peptides in the mass range between 540-3310 Da. The experimental measurement of the CCS is complemented by their calculation applying two different methods. One prediction method is the intrinsic size parameter (ISP) method developed by the Clemmer group. The second new method is based on the evaluation of molecular dynamics (MD) simulation trajectories as a whole, resulting in a single, averaged collision cross-section value for a given peptide in the gas phase. A high temperature MD simulation is run in order to scan through the whole conformational space. The lower temperature conformational distribution is obtained through thermodynamic reweighting. In the first part, various correlations, e.g. CCS vs. mass and inverse mobility vs. m/z correlations, are presented. Differences in CCS between peptides are also discussed in terms of their respective mass and m/z differences, as well as their respective structures. In the second part, measured and calculated CCS are compared. The agreement between the prediction results and the experimental values is in the same range for both calculation methods. While the calculation effort of the ISP method is much lower, the MD method comprises several tools providing deeper insights into the conformations of peptides. Advantages and limitations of both methods are discussed. Based on the separation of two pairs of linear and cyclic peptides of virtually the same mass, the influence of the structure on the cross sections is discussed. The shift in cross section differences and peak shape after transition from the linear to the cyclic peptide can be well understood by applying different MD tools, e.g. the root-mean-square deviation (RMSD) and the root mean square fluctuation (RMSF). (C) 2018 Elsevier B.V. All rights reserved. KW - Ion mobility spectrometry KW - Electrospray ionization KW - Peptides KW - Collision cross-section KW - Molecular dynamics Y1 - 2019 U6 - https://doi.org/10.1016/j.ijms.2018.10.036 SN - 1387-3806 SN - 1873-2798 VL - 436 SP - 108 EP - 117 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Prüfert, Chris A1 - Urban, Raphael David A1 - Fischer, Tillmann Georg A1 - Villatoro, José Andrés A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Belder, Detlev A1 - Zeitler, Kirsten A1 - Löhmannsröben, Hans-Gerd T1 - In situ monitoring of photocatalyzed isomerization reactions on a microchip flow reactor by IR-MALDI ion mobility spectrometry JF - Analytical and bioanalytical chemistry : a merger of Fresenius' journal of analytical chemistry, Analusis and Quimica analitica N2 - The visible-light photocatalyticE/Zisomerization of olefins can be mediated by a wide spectrum of triplet sensitizers (photocatalysts). However, the search for the most efficient photocatalysts through screenings in photo batch reactors is material and time consuming. Capillary and microchip flow reactors can accelerate this screening process. Combined with a fast analytical technique for isomer differentiation, these reactors can enable high-throughput analyses. Ion mobility (IM) spectrometry is a cost-effective technique that allows simple isomer separation and detection on the millisecond timescale. This work introduces a hyphenation method consisting of a microchip reactor and an infrared matrix-assisted laser desorption ionization (IR-MALDI) ion mobility spectrometer that has the potential for high-throughput analysis. The photocatalyzedE/Zisomerization of ethyl-3-(pyridine-3-yl)but-2-enoate (E-1) as a model substrate was chosen to demonstrate the capability of this device. Classic organic triplet sensitizers as well as Ru-, Ir-, and Cu-based complexes were tested as catalysts. The ionization efficiency of theZ-isomer is much higher at atmospheric pressure which is due to a higher proton affinity. In order to suppress proton transfer reactions by limiting the number of collisions, an IM spectrometer working at reduced pressure (max. 100 mbar) was employed. This design reduced charge transfer reactions and allowed the quantitative determination of the reaction yield in real time. Among 14 catalysts tested, four catalysts could be determined as efficient sensitizers for theE/Zisomerization of ethyl cinnamate derivativeE-1. Conversion rates of up to 80% were achieved in irradiation time sequences of 10 up to 180 s. With respect to current studies found in the literature, this reduces the acquisition times from several hours to only a few minutes per scan. KW - microchip KW - reaction monitoring KW - IR-MALDI KW - ion mobility spectrometry KW - photochemistry KW - photocatalysis KW - Olefin isomerization Y1 - 2020 U6 - https://doi.org/10.1007/s00216-020-02923-y SN - 1618-2642 SN - 1618-2650 VL - 412 IS - 28 SP - 7899 EP - 7911 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Villatoro, José Andrés A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Riedel, Jens A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - IR-MALDI ion mobility spectrometry JF - Analytical and bioanalytical chemistry : a merger of Fresenius' journal of analytical chemistry and Analusis N2 - The novel combination of infrared matrix-assisted laser dispersion and ionization (IR-MALDI) with ion mobility (IM) spectrometry makes it possible to investigate biomolecules in their natural environment, liquid water. As an alternative to an ESI source, the IR-MALDI source was implemented in an in-house-developed ion mobility (IM) spectrometer. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse (lambda = 2.94 mu m, 6 ns pulse width), which disperses the liquid as nano- and micro-droplets. The prerequisites for the application of IR-MALDI-IM spectrometry as an analytical method are narrow analyte ion signal peaks for a high spectrometer resolution. This can only be achieved by improving the desolvation of ions. One way to full desolvation is to give the cluster ions sufficient time to desolvate. Two methods for achieving this are studied: the implementation of an additional drift tube, as in ESI-IM-spectrometry, and the delayed extraction of the ions. As a result of this optimization procedure, limits of detection between 5 nM and 2.5 mu M as well as linear dynamic ranges of 2-3 orders of magnitude were obtained for a number of substances. The ability of this method to analyze simple mixtures is illustrated by the separation of two different surfactant mixtures. KW - Ion mobility spectrometry KW - IR-MALDI KW - Laser Y1 - 2016 U6 - https://doi.org/10.1007/s00216-016-9739-x SN - 1618-2642 SN - 1618-2650 VL - 408 SP - 6259 EP - 6268 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Villatoro, José Andrés A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Weber, Marcus A1 - Riedel, Jens A1 - Löhmannsröben, Hans-Gerd T1 - IR-MALDI ion mobility spectrometry: physical source characterization and application as HPLC detector JF - International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry N2 - Infrared matrix-assisted laser dispersion and ionization (IR-MALDI) in combination with ion mobility (IM) spectrometry enables the direct analysis of biomolecules in aqueous solution. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse, which disperses the liquid as vapor, nano-and micro-droplets. The ionization process is characterized initially by a broad spatial distribution of the ions, which is a result of complex fluid dynamics and desolvation kinetics. These processes have a profound effect on the shape and width of the peaks in the IM spectra. In this work, the transport of ions by the phase explosion-induced shockwave could be studied independently from the transport by the electric field. The shockwave-induced mean velocities of the ions at different time scales were determined through IM spectrometry and shadowgraphy. The results show a deceleration of the ions from 118 m.s(-1) at a distance of 400 mu m from the liquid surface to 7.1 m.s(-1) at a distance of 10 mm, which is caused by a pile-up effect. Furthermore, the desolvation kinetics were investigated and a first-order desolvation constant of 325 +/- 50 s(-1) was obtained. In the second part, the IR-MALDI-IM spectrometer is used as an HPLC detector for the two-dimensional separation of a pesticide mixture. KW - Ion mobility spectrometry KW - IR-MALDI KW - Shadowgraphy KW - Laser KW - Imaging KW - HPLC Y1 - 2016 U6 - https://doi.org/10.1007/s12127-016-0208-1 SN - 1435-6163 SN - 1865-4584 VL - 19 SP - 197 EP - 207 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Villatoro Leal, José Andrés A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Weber, Marcus A1 - Löhmannsröben, Hans-Gerd T1 - Sub-ambient pressure IR-MALDI ion mobility spectrometer for the determination of low and high field mobilities JF - Analytical and bioanalytical chemistry : a merger of Fresenius' journal of analytical chemistry, Analusis and Quimica analitica N2 - A new ion mobility (IM) spectrometer, enabling mobility measurements in the pressure range between 5 and 500 mbar and in the reduced field strength range E/N of 5-90 Td, was developed and characterized. Reduced mobility (K-0) values were studied under low E/N (constant value) as well as high E/N (deviation from low field K-0) for a series of molecular ions in nitrogen. Infrared matrix-assisted laser desorption ionization (IR-MALDI) was used in two configurations: a source working at atmospheric pressure (AP) and, for the first time, an IR-MALDI source working with a liquid (aqueous) matrix at sub-ambient/reduced pressure (RP). The influence of RP on IR-MALDI was examined and new insights into the dispersion process were gained. This enabled the optimization of the IM spectrometer for best analytical performance. While ion desolvation is less efficient at RP, the transport of ions is more efficient, leading to intensity enhancement and an increased number of oligomer ions. When deciding between AP and RP IR-MALDI, a trade-off between intensity and resolving power has to be considered. Here, the low field mobility of peptide ions was first measured and compared with reference values from ESI-IM spectrometry (at AP) as well as collision cross sections obtained from molecular dynamics simulations. The second application was the determination of the reduced mobility of various substituted ammonium ions as a function of E/N in nitrogen. The mobility is constant up to a threshold at high E/N. Beyond this threshold, mobility increases were observed. This behavior can be explained by the loss of hydrated water molecules. KW - ion mobility spectrometry KW - IR-MALDI KW - high field mobility KW - dub-ambient KW - pressure KW - peptides Y1 - 2020 U6 - https://doi.org/10.1007/s00216-020-02735-0 SN - 1618-2642 SN - 1618-2650 VL - 412 IS - 22 SP - 5247 EP - 5260 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Salffner, Katharina A1 - Boehm, Michael A1 - Reich, Oliver A1 - Löhmannsröben, Hans-Gerd T1 - A broadband cavity ring-down spectrometer based on an incoherent near infrared light source JF - Applied physics : B, Lasers and optics Y1 - 2014 U6 - https://doi.org/10.1007/s00340-014-5762-9 SN - 0946-2171 SN - 1432-0649 VL - 116 IS - 4 SP - 785 EP - 792 PB - Springer CY - New York ER - TY - JOUR A1 - Schael, Frank A1 - Reich, Oliver A1 - Löhmannsröben, Hans-Gerd T1 - Near infrared diode laser spectroscopy of organic compounds in turbid aqueous solutions N2 - Diffuse reflectance measurements and photon migration studies with near infrared (NIR) diode lasers were employed to elucidate experimental methods for determining absorption and scattering coefficients and species concentrations in highly scattering solutions. Applicability of theoretical approaches were established by investigating model systems with absorbing (e.g. ink, malachite green) and scattering (e.g. milk powder, caolinit) species in aqueous solution. While diffuse reflectance measurements practically requires calibration procedures, photon migration studies allow quantitative determination of absorption and scattering coefficients of turbid solutions consistent with absorptions coefficients obtained from Lambert-Beer's law. Furthermore, NIR absorption spectra of water, chlorinated hydrocarbons (chloroform, 1,2-dichloroethane, trichloroethene) and of various sugars ($alpha$-D-glucose, sucrose, maltose) are discussed. Spectral variations of NIR water absorption with temperature and solvents are exammined. Exemplary, NIR diode laser detection of water in acetone/water mixtures is performed. Y1 - 2000 SN - 0-9528666-1-7 ER - TY - JOUR A1 - Löhmannsröben, Hans-Gerd A1 - Schael, Frank A1 - Reich, Oliver A1 - Lemke, Matthias A1 - Schober, Lars T1 - Untersuchung von organischer Bodensubstanz und Bodengasen mit laser-spektroskopischer in-situ Meßtechnik Y1 - 2000 ER - TY - JOUR A1 - Rethfeldt, Nina A1 - Brinkmann, Pia A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Köllner, Nicole A1 - Altenberger, Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Detection of Rare Earth Elements in Minerals and Soils by Laser-Induced Breakdown Spectroscopy (LIBS) Using Interval PLS JF - Minerals N2 - The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text KW - LIBS KW - rare earth elements KW - minerals KW - PCA KW - iPLS regression Y1 - 2021 U6 - https://doi.org/10.3390/min11121379 SN - 2075-163X VL - 11 SP - 1 EP - 17 PB - MDPI CY - Basel, Schweiz ER - TY - JOUR A1 - Michalik-Onichimowska, Aleksandra A1 - Beitz, Toralf A1 - Panne, Ulrich A1 - Löhmannsröben, Hans-Gerd A1 - Riedel, Jens T1 - Microsecond mid-infrared laser pulses for atmospheric pressure laser ablation/ionization of liquid samples JF - Sensors and actuators : B, Chemical N2 - In many laser based ionization techniques with a subsequent drift time separation, the laser pulse generating the ions is considered as the start time to. Therefore, an accurate temporal definition of this event is crucial for the resolution of the experiments. In this contribution, the laser induced plume dynamics of liquids evaporating into atmospheric pressure are visualized for two distinctively different laser pulse widths, Delta t = 6 nanoseconds and Delta tau = 280 microseconds. For ns-pulses the expansion of the generated vapour against atmospheric pressure is found to lead to turbulences inside the gas phase. This results in spatial and temporal broadening of the nascent clouds. A more equilibrated expansion, without artificial smearing of the temporal resolution can, in contrast, be observed to follow mu s-pulse excitation. This leads to the counterintuitive finding that longer laser pulses results in an increased temporal vapour formation definition. To examine if this fume expansion also eventually results in a better definition of ion formation, the nascent vapour plumes were expanded into a linear drift tube ion mobility spectrometer (IMS). This time resolved detection of ion formation corroborates the temporal broadening caused by collisional impeding of the supersonic expansion at atmospheric pressure and the overall better defined ion formation by evaporation with long laser pulses. A direct comparison of the observed results strongly suggests the coexistence of two individual ion formation mechanisms that can be specifically addressed by the use of appropriate laser sources. KW - Laser ablation KW - Ion mobility spectrometry KW - Pulse duration KW - Plume KW - Ionization Y1 - 2016 U6 - https://doi.org/10.1016/j.snb.2016.06.155 SN - 0925-4005 VL - 238 SP - 298 EP - 305 PB - Elsevier CY - Lausanne ER - TY - JOUR A1 - Meiling, Till Thomas A1 - Cywinski, Piotr J. A1 - Löhmannsröben, Hans-Gerd T1 - Two-Photon excitation fluorescence spectroscopy of quantum dots BT - photophysical properties and application in bioassays JF - The journal of physical chemistry : C, Nanomaterials and interfaces N2 - The applications of quantum dots (QDs) in two-photon (2P) excitation applications demand reliable data about their 2P absorption (2PA) cross sections (sigma(2PA)). In the present study, sigma(2PA) values have been determined for a series of commercial colloidal CdSe/ZnS QDs and CdSeTe/ZnS QDs in aqueous media. For the first time for these QDs, the sigma(2PA) values have been determined over a wide spectral range, that is, between 720 and 900 nm, and are compared to the extinction coefficient (epsilon) values obtained under one-photon (1P) excitation. Furthermore, we present a QD in combination with an organic dye in a biotin-streptavidin Forster resonance energy transfer bioassay under 1P and 2P excitation. The results for the bioassay under 2P excitation are compared to those obtained under 1P excitation. The results demonstrate that in the case of the 2P excitation, higher sensitivity can be achieved because of an improved signal-to-noise ratio. Y1 - 2018 U6 - https://doi.org/10.1021/acs.jpcc.7b12345 SN - 1932-7447 SN - 1932-7455 VL - 122 IS - 17 SP - 9641 EP - 9647 PB - American Chemical Society CY - Washington ER - TY - JOUR A1 - Michalik-Onichimowska, Aleksandra A1 - Beitz, Toralf A1 - Panne, Ulrich A1 - Löhmannsröben, Hans-Gerd A1 - Riedel, Jens T1 - Laser ionization ion mobility spectrometric interrogation of acoustically levitated droplets JF - Analytical and bioanalytical chemistry : a merger of Fresenius' journal of analytical chemistry, Analusis and Quimica analitica N2 - Acoustically levitated droplets have been suggested as compartmentalized, yet wall-less microreactors for high-throughput reaction optimization purposes. The absence of walls is envisioned to simplify up-scaling of the optimized reaction conditions found in the microliter volumes. A consequent pursuance of high-throughput chemistry calls for a fast, robust and sensitive analysis suited for online interrogation. For reaction optimization, targeted analysis with relatively low sensitivity suffices, while a fast, robust and automated sampling is paramount. To follow this approach, in this contribution, a direct coupling of levitated droplets to a homebuilt ion mobility spectrometer (IMS) is presented. The sampling, transfer to the gas phase, as well as the ionization are all performed by a single exposure of the sampling volume to the resonant output of a mid-IR laser. Once formed, the nascent spatially and temporally evolving analyte ion cloud needs to be guided out of the acoustically confined trap into the inlet of the ion mobility spectrometer. Since the IMS is operated at ambient pressure, no fluid dynamic along a pressure gradient can be employed. Instead, the transfer is achieved by the electrostatic potential gradient inside a dual ring electrode ion optics, guiding the analyte ion cloud into the first stage of the IMS linear drift tube accelerator. The design of the appropriate atmospheric pressure ion optics is based on the original vacuum ion optics design of Wiley and McLaren. The obtained experimental results nicely coincide with ion trajectory calculations based on a collisional model. KW - Ambient pressure laser ionization KW - Ionmobility spectrometry KW - Acoustic levitation KW - Ion optics Y1 - 2019 U6 - https://doi.org/10.1007/s00216-019-02167-5 SN - 1618-2642 SN - 1618-2650 VL - 411 IS - 30 SP - 8053 EP - 8061 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Zühlke, Martin A1 - Sass, Stephan A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Real-Time Reaction Monitoring of an Organic Multistep Reaction by Electrospray Ionization-Ion Mobility Spectrometry JF - ChemPlusChem N2 - The capability of electrospray ionization (ESI)-ion mobility (IM) spectrometry for reaction monitoring is assessed both as a stand-alone real-time technique and in combination with HPLC. A three-step chemical reaction, consisting of a Williamson ether synthesis followed by a hydrogenation and an N-alkylation step, is chosen for demonstration. Intermediates and products are determined with a drift time to mass-per-charge correlation. Addition of an HPLC column to the setup increases the separation power and allows the determination of further species. Monitoring of the intensities of the various species over the reaction time allows the detection of the end of reaction, determination of the rate-limiting step, observation of the system response in discontinuous processes, and optimization of the mass ratios of the starting materials. However, charge competition in ESI influences the quantitative detection of substances in the reaction mixture. Therefore, two different methods are investigated, which allow the quantification and investigation of reaction kinetics. The first method is based on the pre-separation of the compounds on an HPLC column and their subsequent individual detection in the ESI-IM spectrometer. The second method involves an extended calibration procedure, which considers charge competition effects and facilitates nearly real-time quantification. KW - electrospray ionization KW - HPLC KW - ion mobility spectrometry KW - reaction mechanisms KW - reaction monitoring Y1 - 2017 U6 - https://doi.org/10.1002/cplu.201700296 SN - 2192-6506 VL - 82 SP - 1266 EP - 1273 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Morgner, Frank A1 - Bennemann, Mark A1 - Cywiński, Piotr J. A1 - Kollosche, Matthias A1 - Górski, Krzysztof A1 - Pietraszkiewicz, Marek A1 - Geßner, André A1 - Löhmannsröben, Hans-Gerd T1 - Elastic FRET sensors for contactless pressure measurement JF - RSC Advances : an international journal to further the chemical sciences N2 - Contactless pressure monitoring based on Forster resonance energy transfer between donor/acceptor pairs immobilized within elastomers is demonstrated. The donor/acceptor energy transfer is employed by dispersing terbium(III) tris[(2-hydroxybenzoyl)-2-aminoethyl] amine complex (LLC, donor) and CdSe/ZnS quantum dots (QD655, acceptor) in styrene-ethylene/buthylene-styrene (SEBS) and poly(dimethylsiloxane) (PDMS). The continuous monitoring of QD luminescence showed a reversible intensity change as the pressure signal is alternated between two stable states indicating a pressure sensitivity of 6350 cps kPa(-1). Time-resolved measurements show the pressure impact on the FRET signal due to an increase of decay time (270 ms up to 420 ms) for the donor signal and parallel drop of decay time (170 mu s to 155 mu s) for the acceptor signal as the net pressure applied. The LLC/QD655 sensors enable a contactless readout as well as space resolved monitoring to enable miniaturization towards smaller integrated stretchable opto-electronics. Elastic FRET sensors can potentially lead to developing profitable analysis systems capable to outdo conventional wired electronic systems (inductive, capacitive, ultrasonic and photoelectric sensors) especially for point-of-care diagnostics, biological monitoring required for wearable electronics. Y1 - 2017 U6 - https://doi.org/10.1039/c7ra06379b SN - 2046-2069 VL - 7 SP - 50578 EP - 50583 PB - RSC Publishing CY - Cambridge ER - TY - JOUR A1 - Prüfert, Christian A1 - Villatoro Leal, José Andrés A1 - Zühlke, Martin A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Liquid phase IR-MALDI and differential mobility analysis of nano- and sub-micron particles JF - Physical chemistry, chemical physics : a journal of European Chemical Societies N2 - Infrared matrix-assisted desorption and ionization (IR-MALDI) enables the transfer of sub-micron particles (sMP) directly from suspensions into the gas phase and their characterization with differential mobility (DM) analysis. A nanosecond laser pulse at 2940 nm induces a phase explosion of the aqueous phase, dispersing the sample into nano- and microdroplets. The particles are ejected from the aqueous phase and become charged. Using IR-MALDI on sMP of up to 500 nm in diameter made it possible to surpass the 100 nm size barrier often encountered when using nano-electrospray for ionizing supramolecular structures. Thus, the charge distribution produced by IR-MALDI could be characterized systematically in the 50-500 nm size range. Well-resolved signals for up to octuply charged particles were obtained in both polarities for different particle sizes, materials, and surface modifications spanning over four orders of magnitude in concentrations. The physicochemical characterization of the IR-MALDI process was done via a detailed analysis of the charge distribution of the emerging particles, qualitatively as well as quantitatively. The Wiedensohler charge distribution, which describes the evolution of particle charging events in the gas phase, and a Poisson-derived charge distribution, which describes the evolution of charging events in the liquid phase, were compared with one another with respect to how well they describe the experimental data. Although deviations were found in both models, the IR-MALDI charging process seems to resemble a Poisson-like charge distribution mechanism, rather than a bipolar gas phase charging one. Y1 - 2022 U6 - https://doi.org/10.1039/d1cp04196g SN - 1463-9076 SN - 1463-9084 VL - 24 IS - 4 SP - 2275 EP - 2286 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Jelicic, Aleksandra A1 - Garcia, Nuria A1 - Löhmannsröben, Hans-Gerd A1 - Beuermann, Sabine T1 - Prediction of the ionic liquid influence on propagation rate coefficients in methyl methacrylate radical polymerizations based on Kamlet-Taft solvatochromic parameters Y1 - 2009 UR - http://pubs.acs.org/journal/mamobx?cookieSet=1 U6 - https://doi.org/10.1021/ma9017907 SN - 0024-9297 ER - TY - JOUR A1 - Hille, Carsten A1 - Lahn, Mattes A1 - Löhmannsröben, Hans-Gerd A1 - Dosche, Carsten T1 - Two-photon fluorescence lifetime imaging of intracellular chloride in cockroach salivary glands Y1 - 2009 UR - http://www.rsc.org/Publishing/Journals/pp/index.asp U6 - https://doi.org/10.1039/B813797H SN - 1474-905X ER - TY - JOUR A1 - Geissler, Daniel A1 - Stufler, Stefan A1 - Löhmannsröben, Hans-Gerd A1 - Hildebrandt, Niko T1 - Six-color time-resolved forster resonance energy transfer for ultrasensitive multiplexed biosensing JF - Journal of the American Chemical Society N2 - Simultaneous monitoring of multiple molecular interactions and multiplexed detection of several diagnostic biomarkers at very low concentrations have become important issues in advanced biological and chemical sensing. Here we present an optically multiplexed six-color Forster resonance energy transfer (FRET) biosensor for simultaneous monitoring of five different individual binding events. We combined simultaneous FRET from one Tb complex to five different organic dyes measured in a filter-based time-resolved detection format with a sophisticated spectral crosstalk correction, which results in very efficient background suppression. The advantages and robustness of the multiplexed FRET sensor were exemplified by analyzing a 15-component lung cancer immunoassay involving 10 different antibodies and five different tumor markers in a single 50 mu L human serum sample. The multiplexed biosensor offers clinically relevant detection limits in the low picomolar (ng/mL) concentration range for all five markers, thus providing an effective early screening tool for lung cancer with the possibility of distinguishing small-cell from non-small-cell lung carcinoma. This novel technology will open new doors for multiple biomarker diagnostics as well as multiplexed real-time imaging and spectroscopy. Y1 - 2013 U6 - https://doi.org/10.1021/ja310317n SN - 0002-7863 VL - 135 IS - 3 SP - 1102 EP - 1109 PB - American Chemical Society CY - Washington ER - TY - JOUR A1 - Harma, Harri A1 - Pihlasalo, Sari A1 - Cywinski, Piotr J. A1 - Mikkonen, Piia A1 - Hammann, Tommy A1 - Löhmannsröben, Hans-Gerd A1 - Hanninen, Pekka T1 - Protein quantification using resonance energy transfer between donor nanoparticles and acceptor quantum dots JF - Analytical chemistry N2 - A homogeneous time-resolved luminescence resonance energy transfer (TR-LRET) assay has been developed to quantify proteins. The competitive assay is based on resonance energy transfer (RET) between two luminescent nanosized particles. Polystyrene nanoparticles loaded with Eu3+ chelates (EuNPs) act as donors, while protein-coated quantum dots (QDs), either CdSe/ZnS emitting at 655 nm (QD655-strep) or CdSeTe/ZnS with emission wavelength at 705 nm (QD705-strep), are acceptors. In the absence of analyte protein, in our case bovine serum albumin (BSA), the protein-coated QDs bind nonspecifically to the EuNPs, leading to RET. In the presence of analyte proteins, the binding of the QDs to the EuNPs is prevented and the RET signal decreases. RET from the EuNPs to the QDs was confirmed and characterized with steady-state and time-resolved luminescence spectroscopy. In accordance with the Forster theory, the approximate average donor acceptor distance is around 15 nm at RET efficiencies, equal to 15% for QD655 and 13% for QD705 acceptor, respectively. The limits of detection are below 10 ng of BSA with less than a 10% average coefficient of variation. The assay sensitivity is improved, when compared to the most sensitive commercial methods. The presented mix-and-measure method has potential to be implemented into routine protein quantification in biological laboratories. Y1 - 2013 U6 - https://doi.org/10.1021/ac303586n SN - 0003-2700 VL - 85 IS - 5 SP - 2921 EP - 2926 PB - American Chemical Society CY - Washington ER - TY - JOUR A1 - Marelja, Zvonimir A1 - Chowdhury, Mita Mullick A1 - Dosche, Carsten A1 - Hille, Carsten A1 - Baumann, Otto A1 - Löhmannsröben, Hans-Gerd A1 - Leimkühler, Silke T1 - The L-cysteine desulfurase NFS1 is localized in the cytosol where it provides the sulfur for molybdenum cofactor biosynthesis in humans JF - PLoS one N2 - In humans, the L-cysteine desulfurase NFS1 plays a crucial role in the mitochondrial iron-sulfur cluster biosynthesis and in the thiomodification of mitochondrial and cytosolic tRNAs. We have previously demonstrated that purified NFS1 is able to transfer sulfur to the C-terminal domain of MOCS3, a cytosolic protein involved in molybdenum cofactor biosynthesis and tRNA thiolation. However, no direct evidence existed so far for the interaction of NFS1 and MOCS3 in the cytosol of human cells. Here, we present direct data to show the interaction of NFS1 and MOCS3 in the cytosol of human cells using Forster resonance energy transfer and a split-EGFP system. The colocalization of NFS1 and MOCS3 in the cytosol was confirmed by immunodetection of fractionated cells and localization studies using confocal fluorescence microscopy. Purified NFS1 was used to reconstitute the lacking molybdoenzyme activity of the Neurospora crassa nit-1 mutant, giving additional evidence that NFS1 is the sulfur donor for Moco biosynthesis in eukaryotes in general. Y1 - 2013 U6 - https://doi.org/10.1371/journal.pone.0060869 SN - 1932-6203 VL - 8 IS - 4 PB - PLoS CY - San Fransisco ER - TY - JOUR A1 - Dosche, Carsten A1 - Löhmannsröben, Hans-Gerd A1 - Bieser, A. A1 - Dosa, P. I. A1 - Han, S. A1 - Iwamoto, M. A1 - Schleifenbaum, A. A1 - Vollhardt, K. Peter C. T1 - Photophysical properties of [N]phenylenes Y1 - 2002 ER - TY - JOUR A1 - Geißler, Daniel A1 - Charbonnière, Loïc J. A1 - Ziessel, Raymond F. A1 - Butlin, Nathaniel G. A1 - Löhmannsröben, Hans-Gerd A1 - Hildebrandt, Niko T1 - Quantum dot biosensors for ultrasensitive multiplexed diagnostics N2 - Time- and color-resolved detection of Foerster resonance energy transfer (FRET) from luminescent terbium complexes to different semiconductor quantum dots results in a fivefold multiplexed bioassay with sub-picomolar detection limits for all five bioanalytes (see picture). The detection of up to five biomarkers occurs with a sensitivity that is 40-240-fold higher than one of the best-established single-analyte reference assays. Y1 - 2010 UR - http://www3.interscience.wiley.com/cgi-bin/jhome/26737/ U6 - https://doi.org/10.1002/anie.200906399 SN - 1433-7851 ER - TY - JOUR A1 - Eich, Susanne A1 - Schmälzlin, Elmar A1 - Löhmannsröben, Hans-Gerd T1 - Distributed fiber optical sensing of Oxygen with optical time domain reflectometry JF - Sensors N2 - In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements. KW - OTDR KW - optical sensing KW - molecular oxygen KW - triangular-[4] phenylene Y1 - 2013 U6 - https://doi.org/10.3390/s130607170 SN - 1424-8220 VL - 13 IS - 6 SP - 7170 EP - 7183 PB - MDPI CY - Basel ER - TY - JOUR A1 - Laudien, Robert A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Detection of explosive related nitroaromatic compounds (ERNC) by laser-based ion mobility spectrometry Y1 - 2008 SN - 978-0-8194-7348-6 ER - TY - JOUR A1 - Rasch, Claudia A1 - Kumke, Michael Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Mykotoxine in Getreide spektroskopisch erfassen Y1 - 2008 ER - TY - JOUR A1 - Kumke, Michael Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Introduction to fluorescence spectroscopy Y1 - 2009 ER - TY - JOUR A1 - Dosche, Carsten A1 - Mickler, Wulfhard A1 - Löhmannsröben, Hans-Gerd A1 - Agenet, Nicolas A1 - Vollhardt, K. Peter C. T1 - Photoinduced electron transfer in [N]phenylenes N2 - First studies of electron transfer in [N]phenylenes were performed in bimolecular quenching reactions of angular [3]- and triangular [4]phenylene with various electron acceptors. The relation between the quenching rate constants k(q) and the free energy change of the electron transfer (Delta G(CS)(0)) could be described by the Rehm- Weller equation. From the experimental results, a reorganization energy lambda of 0.7 eV was derived. Intramolecular electron transfer reactions were studied in an [N]phenylene bichomophore and a corresponding reference compound. Fluorescence lifetime and quantum yield of the bichromophor display a characteristic dependence on the solvent polarity, whereas the corresponding values of the reference compound remain constant. From the results, a nearly isoenergonic charge separation process can be determined. As the triplet quantum yield is nearly independent of the polarity, charge recombination leads to the population of the triplet state. Y1 - 2007 UR - http://www.sciencedirect.com/science/journal/10106030 U6 - https://doi.org/10.1016/j.jphotochem.2006.12.038 SN - 1010-6030 ER - TY - JOUR A1 - Brendler, Christian A1 - Riebe, Daniel A1 - Ritschel, Thomas A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Investigation of neuroleptics and other aromatic compounds by laser-based ion mobility mass spectrometry JF - Analytical & bioanalytical chemistry N2 - Laser-based ion mobility (IM) spectrometry was used for the detection of neuroleptics and PAH. A gas chromatograph was connected to the IM spectrometer in order to investigate compounds with low vapour pressure. The substances were ionized by resonant two-photon ionization at the wavelengths lambda = 213 and 266 nm and pulse energies between 50 and 300 mu J. Ion mobilities, linear ranges, limits of detection and response factors are reported. Limits of detection for the substances are in the range of 1-50 fmol. Additionally, the mechanism of laser ionization at atmospheric pressure was investigated. First, the primary product ions were determined by a laser-based time-of-flight mass spectrometer with effusive sample introduction. Then, a combination of a laser-based IM spectrometer and an ion trap mass spectrometer was developed and characterized to elucidate secondary ion-molecule reactions that can occur at atmospheric pressure. Some substances, namely naphthalene, anthracene, promazine and thioridazine, could be detected as primary ions (radical cations), while other substances, in particular acridine, phenothiazine and chlorprothixene, are detected as secondary ions (protonated molecules). The results are interpreted on the basis of quantum chemical calculations, and an ionization mechanism is proposed. KW - Ion mobility spectrometry KW - Mass spectrometry KW - Gas chromatography KW - Laser ionization KW - REMPI KW - Neuroleptics Y1 - 2013 U6 - https://doi.org/10.1007/s00216-012-6654-7 SN - 1618-2642 VL - 405 IS - 22 SP - 7019 EP - 7029 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Riebe, Daniel A1 - Laudien, Robert A1 - Brendler, Christian A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Laser ionization of H2S and ion-molecule reactions of H3S+ in laser-based ion mobility spectrometry and drift cell time-of-flight mass spectrometry JF - Analytical & bioanalytical chemistry N2 - The detection of hydrogen sulfide (H2S) by 2 + 1 resonance-enhanced multi-photon ionization (REMPI) and the application of H2S as a laser dopant for the detection of polar compounds in laser ion mobility (IM) spectrometry at atmospheric pressure were investigated. Underlying ionization mechanisms were elucidated by additional studies employing a drift cell interfaced to a time-of-flight mass spectrometer. Depending on the pressure, the primary ions H2S+, HS+, S+, and secondary ions, such as H3S+, were observed. The 2 + 1 REMPI spectrum of H2S near lambda = 302.5 nm was recorded at atmospheric pressure. Furthermore, the limit of detection and the linear range were established. In the second part of the work, H2S was investigated as an H2O analogous laser dopant for the ionization of polar substances by proton transfer. H2S exhibits a proton affinity (PA) similar to that of H2O, but a significantly lower ionization energy facilitating laser ionization. Ion-molecule reactions (IMR) of H3S+ with a variety of polar substances with PA between 754.6 and 841.6 kJ/mol were investigated. Representatives of different compound classes, including alcohols, ketones, esters, and nitroaromatics were analyzed. The IM spectra resulting from IMR of H3S+ and H3O+ with these substances are similar in structure, i.e., protonated monomer and dimer ion peaks are found depending on the analyte concentration. KW - Ion mobility spectrometry KW - Mass spectrometry KW - REMPI KW - Hydrogen sulfide KW - Proton transfer reaction Y1 - 2013 U6 - https://doi.org/10.1007/s00216-013-7186-5 SN - 1618-2642 VL - 405 IS - 22 SP - 7031 EP - 7039 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Sagolla, Kristina A1 - Löhmannsröben, Hans-Gerd A1 - Hille, Carsten T1 - Time-resolved fluorescence microscopy for quantitative Ca2+ imaging in living cells JF - Analytical & bioanalytical chemistry N2 - Calcium (Ca2+) is a ubiquitous intracellular second messenger and involved in a plethora of cellular processes. Thus, quantification of the intracellular Ca2+ concentration ([Ca2+](i)) and of its dynamics is required for a comprehensive understanding of physiological processes and potential dysfunctions. A powerful approach for studying [Ca2+](i) is the use of fluorescent Ca2+ indicators. In addition to the fluorescence intensity as a common recording parameter, the fluorescence lifetime imaging microscopy (FLIM) technique provides access to the fluorescence decay time of the indicator dye. The nanosecond lifetime is mostly independent of variations in dye concentration, allowing more reliable quantification of ion concentrations in biological preparations. In this study, the feasibility of the fluorescent Ca2+ indicator Oregon Green Bapta-1 (OGB-1) for two-photon fluorescence lifetime imaging microscopy (2P-FLIM) was evaluated. In aqueous solution, OGB-1 displayed a Ca2+-dependent biexponential fluorescence decay behaviour, indicating the presence of a Ca2+-free and Ca2+-bound dye form. After sufficient dye loading into living cells, an in situ calibration procedure has also unravelled the Ca2+-free and Ca2+-bound dye forms from a global biexponential fluorescence decay analysis, although the dye's Ca2+ sensitivity is reduced. Nevertheless, quantitative [Ca2+](i) recordings and its stimulus-induced changes in salivary gland cells could be performed successfully. These results suggest that OGB-1 is suitable for 2P-FLIM measurements, which can gain access to cellular physiology. KW - Fluorescence lifetime KW - TCSPC KW - Two-photon excitation KW - 2P cross section KW - Epithelial ion transport KW - OGB-1 Y1 - 2013 U6 - https://doi.org/10.1007/s00216-013-7290-6 SN - 1618-2642 VL - 405 IS - 26 SP - 8525 EP - 8537 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Kumke, Michael Uwe A1 - Dosche, Carsten A1 - Flehr, Roman A1 - Trowitzsch-Kienast, Wolfram A1 - Löhmannsröben, Hans-Gerd T1 - Spectroscopic characterization of the artificial siderophore pyridinochelin Y1 - 2006 UR - http://www.znaturforsch.com/c.htm SN - 0939-5075 ER - TY - JOUR A1 - Geißler, Daniel A1 - Butlin, Nathaniel G. A1 - Hill, Diana A1 - Löhmannsröben, Hans-Gerd A1 - Hildebrandt, Niko T1 - Multiplexed diagnostics and spectroscopic ruler applications with terbium to quantum dots FRET Y1 - 2008 SN - 1605-7422 ER - TY - JOUR A1 - Geißler, Daniel A1 - Charbonnière, Loïc J. A1 - Ziessel, Raymond F. A1 - Löhmannsröben, Hans-Gerd T1 - Quantum dots as FRET acceptors for highly sensitive multiplexing immunoassays Y1 - 2009 ER - TY - JOUR A1 - Engelhard, Sonja A1 - Kumke, Michael Uwe A1 - Löhmannsröben, Hans-Gerd T1 - Examples of the application of optical process and quality sensing (OPQS) to beer brewing and polyurethane foaming processes N2 - Optical methods play an important role in process analytical technologies (PAT). Four examples of optical process and quality sensing (OPQS) are presented, which are based on three important experimental techniques: near- infrared absorption, luminescence quenching, and a novel method, photon density wave (PDW) spectroscopy. These are used to evaluate four process and quality parameters related to beer brewing and polyurethane (PU) foaming processes: the ethanol content and the oxygen (O-2) content in beer, the biomass in a bioreactor, and the cellular structures of PU foam produced in a pilot production plant Y1 - 2006 UR - http://www.springerlink.com/content/100417 U6 - https://doi.org/10.1007/s00216-005-3364-4 SN - 1618-2642 ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Nono, Katia Nchimi A1 - Charbonniere, Loic J. A1 - Hammann, Tommy A1 - Löhmannsröben, Hans-Gerd T1 - Photophysical evaluation of a new functional terbium complex in FRET-based time-resolved homogenous fluoroassays JF - Physical chemistry, chemical physics : a journal of European Chemical Societies N2 - A new functional luminescent lanthanide complex (LLC) has been synthesized with terbium as a central lanthanide ion and biotin as a functional moiety. Unlike in typical lanthanide complexes assembled via carboxylic moieties, in the presented complex, four phosphate groups are chelating the central lanthanide ion. This special chemical assembly enhances the complex stability in phosphate buffers conventionally used in biochemistry. The complex synthesis strategy and photophysical properties are described as well as the performance in time-resolved Forster Resonance Energy Transfer (FRET) assays. In those assays, this biotin-LLC transferred energy either to acceptor organic dyes (Cy5 or AF680) labelled on streptavidin or to quantum dots (QD655 or QD705) surfacefunctionalised with streptavidins. The permanent spatial donor-acceptor proximity is assured through strong and stable biotin-streptavidin binding. The energy transfer is evidenced from the quenching observed in donor emission and from a decrease in donor luminescence decay, both associated with simultaneous increase in acceptor intensity and in the decay time. The dye-based assays are realised in TRIS and in PBS, whereas QD-based systems are studied in borate buffer. The delayed emission analysis allows for quantifying the recognition process and for auto-fluorescence-free detection, which is particularly relevant for application in bioanalysis. In accordance with Forster theory, Forsterradii (R0) were found to be around 60 angstrom for organic dyes and around 105 angstrom for QDs. The FRET efficiency (Z) reached 80% and 25% for dye and QD acceptors, respectively. Physical donor-acceptor distances (r) have been determined in the range 45-60 angstrom for organic dye acceptors, while for acceptor QDs between 120 angstrom and 145 angstrom. This newly synthesised biotin-LLC extends the class of highly sensitive analytical tools to be applied in the bioanalytical methods such as time-resolved fluoroimmunoassays (TR-FIA), luminescent imaging and biosensing. Y1 - 2014 U6 - https://doi.org/10.1039/c3cp54883j SN - 1463-9076 SN - 1463-9084 VL - 16 IS - 13 SP - 6060 EP - 6067 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Zakrevskyy, Y. A1 - Ritschel, T. A1 - Dosche, C. A1 - Löhmannsröben, Hans-Gerd T1 - Quantitative calibration - and reference-free wavelength modulation spectroscopy JF - Infrared physics & technology N2 - A unified model for quantitative description of harmonic spectra of gases obtained by wavelength modulation spectroscopy (WMS) technique is presented. In the model, both intensity modulation (IM) and frequency modulation (FM) of the laser emission are taken into account using minimum number of parameters. For the first time, the static behavior of a laser is described as a limiting case of its dynamic response. Laser and its driver are considered as a single device converting applied bias to laser emission. This allows application of the model to any type of laser and the introduced parameters can be assigned to the corresponding laser and/or driver properties. The approach was tested using a distributed feedback (DFB) laser spectrometer. Correctness of the proposed model is justified by very good agreement between the measured and modeled/fitted spectra, which allowed evaluation of the setup performance and assessment of modulation parameters of the DFB laser. An algorithm to minimize the time of numerical calculation of harmonic spectra using numerically approximated Voigt lineshape function was developed. Absolute values of the absorption line parameters (line strength and line width) were obtained from a single calibration- and reference-free spectrum scan with accuracy better than 0.1%. KW - Wavelength modulation gas spectroscopy KW - Diode laser KW - Isotope detection Y1 - 2012 U6 - https://doi.org/10.1016/j.infrared.2011.12.001 SN - 1350-4495 VL - 55 IS - 2-3 SP - 183 EP - 190 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Hammann, Tommy A1 - Huehn, Dominik A1 - Parak, Wolfgang J. A1 - Hildebrandt, Niko A1 - Löhmannsröben, Hans-Gerd T1 - Europium-quantum dot nanobioconjugates as luminescent probes for time-gated biosensing JF - Journal of biomedical optics N2 - Nanobioconjugates have been synthesized using cadmium selenide quantum dots (QDs), europium complexes (EuCs), and biotin. In those conjugates, long-lived photoluminescence (PL) is provided by the europium complexes, which efficiently transfer energy via Forster resonance energy transfer (FRET) to the QDs in close spatial proximity. As a result, the conjugates have a PL emission spectrum characteristic for QDs combined with the long PL decay time characteristic for EuCs. The nanobioconjugates synthesis strategy and photo-physical properties are described as well as their performance in a time-resolved streptavidin-biotin PL assay. In order to prepare the QD-EuC-biotin conjugates, first an amphiphilic polymer has been functionalized with the EuC and biotin. Then, the polymer has been brought onto the surface of the QDs (either QD655 or QD705) to provide functionality and to make the QDs water dispersible. Due to a short distance between EuC and QD, an efficient FRET can be observed. Additionally, the QD-EuC-biotin conjugates' functionality has been demonstrated in a PL assay yielding good signal discrimination, both from autofluorescence and directly excited QDs. These newly designed QD-EuC-biotin conjugates expand the class of highly sensitive tools for bioanalytical optical detection methods for diagnostic and imaging applications. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE) KW - quantum dots KW - europium complex KW - amphiphilic polymer assembly KW - nanobioconjugate KW - biosensor KW - time-resolved fluorescence Y1 - 2014 U6 - https://doi.org/10.1117/1.JBO.19.10.101506 SN - 1083-3668 SN - 1560-2281 VL - 19 IS - 10 PB - SPIE CY - Bellingham ER - TY - JOUR A1 - Bland-Hawthorn, Joss A1 - Ellis, S. C. A1 - Leon-Saval, S. G. A1 - Haynes, R. A1 - Roth, Martin M. A1 - Löhmannsröben, Hans-Gerd A1 - Horton, A. J. A1 - Cuby, J. -G. A1 - Birks, T. A. A1 - Lawrence, J. S. A1 - Gillingham, P. A1 - Ryder, S. D. A1 - Trinh, C. T1 - A complex multi-notch astronomical filter to suppress the bright infrared sky JF - Nature Communications N2 - A long-standing and profound problem in astronomy is the difficulty in obtaining deep near-infrared observations due to the extreme brightness and variability of the night sky at these wavelengths. A solution to this problem is crucial if we are to obtain the deepest possible observations of the early Universe, as redshifted starlight from distant galaxies appears at these wavelengths. The atmospheric emission between 1,000 and 1,800 nm arises almost entirely from a forest of extremely bright, very narrow hydroxyl emission lines that varies on timescales of minutes. The astronomical community has long envisaged the prospect of selectively removing these lines, while retaining high throughput between them. Here we demonstrate such a filter for the first time, presenting results from the first on-sky tests. Its use on current 8 m telescopes and future 30 m telescopes will open up many new research avenues in the years to come. Y1 - 2011 U6 - https://doi.org/10.1038/ncomms1584 SN - 2041-1723 VL - 2 IS - 50 PB - Nature Publ. Group CY - London ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Moro, Artur J. A1 - Löhmannsröben, Hans-Gerd T1 - Cyclic GMP recognition using ratiometric QD-fluorophore conjugate nanosensors JF - Biosensors and bioelectronics : the principal international journal devoted to research, design development and application of biosensors and bioelectronics KW - Quantum dots KW - Naphthyridines KW - Cyclic GMP KW - Base pairing KW - Fluorescent nanoconjugate KW - Nanosensor Y1 - 2014 U6 - https://doi.org/10.1016/j.bios.2013.09.002 SN - 0956-5663 SN - 1873-4235 VL - 52 SP - 288 EP - 292 PB - Elsevier CY - Oxford ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Olejko, Lydia A1 - Löhmannsröben, Hans-Gerd T1 - A time-resolved luminescent competitive assay to detect L-selectin using aptamers as recognition elements JF - Analytica chimica acta : an international journal devoted to all branches of analytical chemistry N2 - L-selectin is a protein with potential importance for numerous diseases and clinical disorders. In this paper, we present a new aptamer-based luminescent assay developed to detect L-selectin. The sensing system working principle is based on Forster Resonance Energy Transfer (FRET) from a donor terbium complex (TbC) to an acceptor cyanine dye (Cy5). In the present approach, the biotinylated aptamer is combined with Cy5-labelled streptavidin (Cy5-Strep) to yield an aptamer-based acceptor construct (Apta-Cy5-Strep), while L-selectin is conjugated using luminescent TbC. Upon aptamer binding to the TbC-labelled L-selectin (L-selectin-TbC), permanent donor-acceptor proximity is established which allows for radiationless energy transfer to occur. However, when unlabelled L-selectin is added, it competes with the L-selectin-TbC and the FRET signal decreases as the L-selectin concentration increases. FRET from the TbC to Cy5 was observed with time-gated time-resolved luminescence spectroscopy. A significant change in the corrected luminescence signal was observed in the dynamic range of 10 -500 ng/mL L-selectin, the concentration range relevant for accelerated cognitive decline of Alzheimer's disease, with a limit of detection (LOD) equal to 10 ng/mL. The aptasensor-based assay is homogeneous and can be realized within one hour. Therefore, this method has the potential to become an alternative to tedious heterogeneous analytical methods, e.g. based on enzyme-linked immunosorbent assay (ELISA). (C) 2015 Elsevier B.V. All rights reserved. KW - Aptamer KW - FRET KW - L-selectin KW - Luminescence spectroscopy KW - Fluoroassay KW - Lanthanide Y1 - 2015 U6 - https://doi.org/10.1016/j.aca.2015.06.045 SN - 0003-2670 SN - 1873-4324 VL - 887 SP - 209 EP - 215 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ellis, S. C. A1 - Bland-Hawthorn, Joss A1 - Lawrence, J. A1 - Horton, A. J. A1 - Trinh, C. A1 - Leon-Saval, S. G. A1 - Shortridge, K. A1 - Bryant, J. A1 - Case, S. A1 - Colless, M. A1 - Couch, W. A1 - Freeman, K. A1 - Gers, L. A1 - Glazebrook, K. A1 - Haynes, R. A1 - Lee, S. A1 - Löhmannsröben, Hans-Gerd A1 - O'Byrne, J. A1 - Miziarski, S. A1 - Roth, M. A1 - Schmidt, B. A1 - Tinney, C. G. A1 - Zheng, J. T1 - Suppression of the near-infrared OH night-sky lines with fibre Bragg gratings - first results JF - Monthly notices of the Royal Astronomical Society N2 - The background noise between 1 and 1.8 ?mu m in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, the Gemini Near-infrared OH Suppression Integral Field Unit (IFU) System (GNOSIS), which suppresses 103 OH doublets between 1.47 and 1.7?mu m by a factor of 1000 with a resolving power of 10?000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph at the Anglo-Australian Telescope. We present measurements of sensitivity, background and throughput. The combined throughput of the GNOSIS fore-optics, grating unit and relay optics is 36?per cent, but this could be improved to 46?per cent with a more optimal design. We measure strong suppression of the OH lines, confirming that OH suppression with fibre Bragg gratings will be a powerful technology for low-resolution spectroscopy. The integrated OH suppressed background between 1.5 and 1.7 mu m is reduced by a factor of 9 compared to a control spectrum using the same system without suppression. The potential of low-resolution OH-suppressed spectroscopy is illustrated with example observations of Seyfert galaxies and a low-mass star. The GNOSIS background is dominated by detector dark current below 1.67 mu m and by thermal emission above 1.67 mu m. After subtracting these, we detect an unidentified residual interline component of 860 +/- 210 photons s-1 m-2?arcsec-2?mu m-1, comparable to previous measurements. This component is equally bright in the suppressed and control spectra. We have investigated the possible source of the interline component, but were unable to discriminate between a possible instrumental artefact and intrinsic atmospheric emission. Resolving the source of this emission is crucial for the design of fully optimized OH suppression spectrographs. The next-generation OH suppression spectrograph will be focused on resolving the source of the interline component, taking advantage of better optimization for a fibre Bragg grating feed incorporating refinements of design based on our findings from GNOSIS. We quantify the necessary improvements for an optimal OH suppressing fibre spectrograph design. KW - atmospheric effects KW - instrumentation: miscellaneous KW - infrared: general Y1 - 2012 U6 - https://doi.org/10.1111/j.1365-2966.2012.21602.x SN - 0035-8711 VL - 425 IS - 3 SP - 1682 EP - 1695 PB - Wiley-Blackwell CY - Hoboken ER - TY - JOUR A1 - Riebe, Daniel A1 - Zühlke, Martin A1 - Zenichowski, Karl A1 - Beitz, Toralf A1 - Dosche, Carsten A1 - Löhmannsröben, Hans-Gerd T1 - Characterization of rhodamine 6G release in electrospray ionization by means of spatially resolved fluorescence spectroscopy JF - Zeitschrift für physikalische Chemie : international journal of research in physical chemistry and chemical physics N2 - In the present work, the density distribution of rhodamine 6G ions (R6G) in the gas phase and the droplets of an electrospray plume was studied by spatial and spectral imaging. The intention is to contribute to the fundamental understanding of the release mechanism of gaseous R6G in the electrospray ionization (ESI) process. Furthermore, the influence of ESI-parameters on the release efficiency of R6G, e. g. solvent flow, R6G and salt concentration were examined via direct fluorescence imaging of R6G. A solvent-shift of the fluorescence maximum,lambda(max) = 555 nm in methanolic solution and lambda(max) = 505 nm in gas phase, allows the discrimination between solvated and gaseous R6G. Two experimental setups were used for our measurements. In the first experiment, the R6G fluorescence and the light scattered from the spray plume were imaged in two spatial dimensions using a tunable wavelength filter. The second experiment was designed for obtaining 1-dimensional spatially resolved emission spectra of the spray. Here, the intensity distribution of solvated and gaseous R6G as well as scattered light (lambda = 355 nm) were measured simultaneously. The results show the distribution of gaseous R6G in the plane, orthogonal to the ESI capillary, decreasing slightly towards the spray center and showing maxima at the cone margins. The distribution of gaseous R6G confirms the preferred release of gaseous ions from nano-droplets, indicating the ion evaporation model (IEM) to be the dominating release mechanism. Up to now, only a few fluorescence spectra of ionic compounds in the gas phase were published because the measurement of emission spectra of mass-selected ions in an ion trap is experimentally challenging. The fluorescence spectrum of gaseous lucigenin at atmospheric pressure is reported for the first time. This spectrum of lucigenin in the gas phase exhibits a blue shift of about Delta lambda = 10 nm in comparison to the corresponding spectrum in methanol. KW - Fluorescence KW - Electrospray Ionization KW - Rhodamine 6G KW - Gaseous Ions KW - Lucigenin Y1 - 2011 U6 - https://doi.org/10.1524/zpch.2011.0149 SN - 0942-9352 VL - 225 IS - 9-10 SP - 1055 EP - 1072 PB - De Gruyter Oldenbourg CY - München ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Moro, Artur J. A1 - Ritschel, Thomas A1 - Hildebrandt, Niko A1 - Löhmannsröben, Hans-Gerd T1 - Sensitive and selective fluorescence detection of guanosine nucleotides by nanoparticles conjugated with a naphthyridine receptor JF - Analytical & bioanalytical chemistry N2 - Novel fluorescent nanosensors, based on a naphthyridine receptor, have been developed for the detection of guanosine nucleotides, and both their sensitivity and selectivity to various nucleotides were evaluated. The nanosensors were constructed from polystyrene nanoparticles functionalized by (N-(7-((3-aminophenyl) ethynyl)-1,8-naphthyridin- 2-yl) acetamide) via carbodiimide ester activation. We show that this naphthyridine nanosensor binds guanosine nucleotides preferentially over adenine, cytosine, and thymidine nucleotides. Upon interaction with nucleotides, the fluorescence of the nanosensor is gradually quenched yielding Stern-Volmer constants in the range of 2.1 to 35.9mM(-1). For all the studied quenchers, limits of detection (LOD) and tolerance levels for the nanosensors were also determined. The lowest (3 sigma) LOD was found for guanosine 3',5'-cyclic monophosphate (cGMP) and it was as low as 150 ng/ml. In addition, we demonstrated that the spatial arrangement of bound analytes on the nanosensors' surfaces is what is responsible for their selectivity to different guanosine nucleotides. We found a correlation between the changes of the fluorescence signal and the number of phosphate groups of a nucleotide. Results of molecular modeling and zeta-potential measurements confirm that the arrangement of analytes on the surface provides for the selectivity of the nanosensors. These fluorescent nanosensors have the potential to be applied in multi-analyte, array-based detection platforms, as well as in multiplexed microfluidic systems. KW - Naphthyridine receptor KW - cGMP KW - Base pairing KW - Nucleotide nanosensor KW - Fluorescence spectroscopy Y1 - 2011 U6 - https://doi.org/10.1007/s00216-010-4420-2 SN - 1618-2642 VL - 399 IS - 3 SP - 1215 EP - 1222 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Dosche, Carsten A1 - Löhmannsröben, Hans-Gerd A1 - Raab, Volker A1 - Raab, Corinna A1 - Unverzagt, Matthias T1 - High-resolution spectrometer using combined dispersive and interferometric wavelength separation for raman and laser-induced Breakdown Spectroscopy (LIBS) JF - Applied spectroscopy : an international journal of spectroscopy ; official publication of the Society for Applied Spectroscopy N2 - In this paper the concept of a compact high-resolution spectrometer based on the combination of dispersive and interferometric elements is presented. Dispersive elements are used to spectrally resolve the light in one direction with coarse resolution (Delta lambda < 0.5 nm), while perpendicular to that direction an etalon provides high spectral resolution (Delta lambda < 50 pm). This concept for two-dimensional spectroscopy has been implemented for the wavelength range lambda = 350-650 nm. Appropriate algorithms for reconstructing spectra from the two-dimensional raw data and for wavelength calibration were established in an analysis software. Potential applications for this new spectrometer are Raman and laser-induced breakdown spectroscopy (LIBS). Resolutions down to 28 pm (routinely 54 pm) could be realized for these applications. KW - Raman spectroscopy KW - Laser-induced breakdown spectroscopy KW - LIBS KW - Fabry-Perot etalon KW - High-resolution spectrometer Y1 - 2014 U6 - https://doi.org/10.1366/13-07426 SN - 0003-7028 SN - 1943-3530 VL - 68 IS - 9 SP - 1030 EP - 1038 PB - Society for Applied Spectroscopy CY - Frederick ER - TY - JOUR A1 - Riebe, Daniel A1 - Erler, Alexander A1 - Brinkmann, Pia A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Gebbers, Robin T1 - Comparison of Calibration Approaches in Laser-Induced Breakdown Spectroscopy for Proximal Soil Sensing in Precision Agriculture JF - Sensors N2 - The lack of soil data, which are relevant, reliable, affordable, immediately available, and sufficiently detailed, is still a significant challenge in precision agriculture. A promising technology for the spatial assessment of the distribution of chemical elements within fields, without sample preparation is laser-induced breakdown spectroscopy (LIBS). Its advantages are contrasted by a strong matrix dependence of the LIBS signal which necessitates careful data evaluation. In this work, different calibration approaches for soil LIBS data are presented. The data were obtained from 139 soil samples collected on two neighboring agricultural fields in a quaternary landscape of northeast Germany with very variable soils. Reference analysis was carried out by inductively coupled plasma optical emission spectroscopy after wet digestion. The major nutrients Ca and Mg and the minor nutrient Fe were investigated. Three calibration strategies were compared. The first method was based on univariate calibration by standard addition using just one soil sample and applying the derived calibration model to the LIBS data of both fields. The second univariate model derived the calibration from the reference analytics of all samples from one field. The prediction is validated by LIBS data of the second field. The third method is a multivariate calibration approach based on partial least squares regression (PLSR). The LIBS spectra of the first field are used for training. Validation was carried out by 20-fold cross-validation using the LIBS data of the first field and independently on the second field data. The second univariate method yielded better calibration and prediction results compared to the first method, since matrix effects were better accounted for. PLSR did not strongly improve the prediction in comparison to the second univariate method. KW - laser-induced breakdown spectroscopy KW - LIBS KW - proximal soil sensing KW - soil nutrients KW - elemental composition Y1 - 2019 U6 - https://doi.org/10.3390/s19235244 SN - 1424-8220 VL - 19 IS - 23 PB - MDPI CY - Basel ER - TY - JOUR A1 - Riebe, Daniel A1 - Eder, Alexander A1 - Ritschel, Thomas A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Beil, Andreas A1 - Blaschke, Michael A1 - Ludwig, Thomas T1 - Atmospheric pressure chemical ionization of explosives induced by soft X-radiation in ion mobility spectrometry: mass spectrometric investigation of the ionization reactions of drift gasses, dopants and alkyl nitrates JF - Journal of mass spectrometr N2 - A promising replacement for the radioactive sources commonly encountered in ion mobility spectrometers is a miniaturized, energy-efficient photoionization source that produce the reactant ions via soft X-radiation (2.8 keV). In order to successfully apply the photoionization source, it is imperative to know the spectrum of reactant ions and the subsequent ionization reactions leading to the detection of analytes. To that end, an ionization chamber based on the photoionization source that reproduces the ionization processes in the ion mobility spectrometer and facilitates efficient transfer of the product ions into a mass spectrometer was developed. Photoionization of pure gasses and gas mixtures containing air, N-2, CO2 and N2O and the dopant CH2Cl2 is discussed. The main product ions of photoionization are identified and compared with the spectrum of reactant ions formed by radioactive and corona discharge sources on the basis of literature data. The results suggest that photoionization by soft X-radiation in the negative mode is more selective than the other sources. In air, adduct ions of O-2 - with H2O and CO2 were exclusively detected. Traces of CO2 impact the formation of adduct ions of O-2 - and Cl -(upon addition of dopant) and are capable of suppressing them almost completely at high CO2 concentrations. Additionally, the ionization products of four alkyl nitrates (ethylene glycol dinitrate, nitroglycerin, erythritol tetranitrate and pentaerythritol tetranitrate) formed by atmospheric pressure chemical ionization induced by X-ray photoionization in different gasses (air, N-2 and N2O) and dopants (CH2Cl2, C2H5Br and CH3I) are investigated. The experimental studies are complemented by density functional theory calculations of the most important adduct ions of the alkyl nitrates (M) used for their spectrometric identification. In addition to the adduct ions [M + NO3](-) and [M + Cl](-), adduct ions such as [M + N2O2](-), [M + Br](-) and [M+ I](-) were detected, and their gas-phase structures and energetics are investigated by density functional theory calculations. Copyright (C) 2016 John Wiley & Sons, Ltd. KW - ion mobility spectrometry KW - mass spectrometry KW - explosives KW - X-ray KW - photoionization KW - alkyl nitrates Y1 - 2016 U6 - https://doi.org/10.1002/jms.3784 SN - 1076-5174 SN - 1096-9888 VL - 51 SP - 566 EP - 577 PB - Wiley-Blackwell CY - Hoboken ER - TY - JOUR A1 - Cywinski, Piotr J. A1 - Pietraszkiewicz, Marek A1 - Maciejczyk, Michal A1 - Gorski, Krzysztof A1 - Hammann, Tommy A1 - Liermann, Konstanze A1 - Paulke, Bernd-Reiner A1 - Löhmannsröben, Hans-Gerd T1 - Total protein concentration quantification using nanobeads with a new highly luminescent terbium(III) complex JF - RSC Advances N2 - Total protein concentration (TPC) is a key parameter in many biochemical experiments and its quantification is often necessary for isolation, separation, and analysis of proteins. A sensitive and rapid nanobead-based TPC quantification assay based on Forster Resonance Energy Transfer (FRET) has been developed. A new, highly luminescent Tb(III) complex has been synthesised and applied as donor in this FRET assay with an organic dye (Cy5) as acceptor. FRET-induced changes in luminescence have been investigated both at donor and acceptor emission wavelength using time-resolved luminescence spectroscopy with time-gated detection. In the assay, the Tb(III) complex and fine-tuned polyglycidyl methacrylate (PGMA) nanobeads ensure that an improvement in sensitivity and background reduction is achieved. Using 40 nm large PGMA nanobeads loaded with the Tb(III) complex, it is possible to determine TPC down to 50 ng mL(-1) in just 10 minutes. Through specific assay components the sensitivity has been improved when compared to existing nanobead-based assays and to currently known commercial methods. Additionally, the assay is relatively insensitive to the presence of contaminants, such as non-ionic detergents commonly found in biological samples. Due to no need for any centrifugal steps, this mix-and-measure bioassay can easily be implemented into routine TPC quantification protocols in biochemical laboratories. Y1 - 2016 U6 - https://doi.org/10.1039/c6ra23207h SN - 2046-2069 VL - 6 SP - 115068 EP - 115073 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Zenichowski, Karl A1 - Diener, Marc A1 - Linscheid, Michael W. T1 - An electrospray ionization-ion mobility spectrometer as detector for high-performance liquid chromatography JF - European journal of mass spectrometry N2 - The application of electrospray ionization (ESI) ion mobility (IM) spectrometry on the detection end of a high-performance liquid chromatograph has been a subject of study for some time. So far, this method has been limited to low flow rates or has required splitting of the liquid flow. This work presents a novel concept of an ESI source facilitating the stable operation of the spectrometer at flow rates between 10 mu L min(-1) and 1500 mu L min(-1) without flow splitting, advancing the T-cylinder design developed by Kurnin and co-workers. Flow rates eight times faster than previously reported were achieved because of a more efficient dispersion of the liquid at increased electrospray voltages combined with nebulization by a sheath gas. Imaging revealed the spray operation to be in a rotationally symmetric multijet-mode. The novel ESI-IM spectrometer tolerates high water contents (<= 90%) and electrolyte concentrations up to 10 mM, meeting another condition required of high-performance liquid chromatography (HPLC) detectors. Limits of detection of 50 nM for promazine in the positive mode and 1 mu M for 1,3-dinitrobenzene in the negative mode were established. Three mixtures of reduced complexity (five surfactants, four neuroleptics, and two isomers) were separated in the millisecond regime in stand-alone operation of the spectrometer. Separations of two more complex mixtures (five neuroleptics and 13 pesticides) demonstrate the application of the spectrometer as an HPLC detector. The examples illustrate the advantages of the spectrometer over the established diode array detector, in terms of additional IM separation of substances not fully separated in the retention time domain as well as identification of substances based on their characteristic IMs. KW - ESI KW - IMS KW - HPLC KW - spray imaging KW - neuroleptics KW - pesticides KW - surfactants Y1 - 2015 U6 - https://doi.org/10.1255/ejms.1367 SN - 1469-0667 SN - 1751-6838 VL - 21 IS - 3 SP - 391 EP - 402 PB - WeltTrends CY - Sussex ER - TY - JOUR A1 - Morgner, Frank A1 - Lecointre, Alexandre A1 - Charbonniere, Loic J. A1 - Löhmannsröben, Hans-Gerd T1 - Detecting free hemoglobin in blood plasma and serum with luminescent terbium complexes JF - Physical chemistry, chemical physics : a journal of European Chemical Societies N2 - Hemolysis, the rupturing of red blood cells, can result from numerous medical conditions (in vivo) or occur after collecting blood specimen or extracting plasma and serum out of whole blood (in vitro). In clinical laboratory practice, hemolysis can be a serious problem due to its potential to bias detection of various analytes or biomarkers. Here we present the first "mix-and-measure' method to assess the degree of hemolysis in biosamples using luminescence spectroscopy. Luminescent terbium complexes (LTC) were studied in the presence of free hemoglobin (Hb) as indicators for hemolysis in TRIS-buffer, and in fresh human plasma with absorption, excitation and emission measurements. Our findings indicate dynamic as well as resonance energy transfer (FRET) between the LTC and the porphyrin ligand of hemoglobin. This transfer leads to a decrease in luminescence intensity and decay time even at nanomolar hemoglobin concentrations either in buffer or plasma. Luminescent terbium complexes are very sensitive to free hemoglobin in buffer and blood plasma. Due to the instant change in luminescence properties of the LTC in presence of Hb it is possible to access the concentration of hemoglobin via spectroscopic methods without incubation time or further treatment of the sample thus enabling a rapid and sensitive detection of hemolysis in clinical diagnostics. Y1 - 2015 U6 - https://doi.org/10.1039/c4cp04206a SN - 1463-9076 SN - 1463-9084 VL - 17 IS - 3 SP - 1740 EP - 1745 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Löhmannsröben, Hans-Gerd A1 - Lemke, Matthias A1 - Schober, Lars A1 - Schultze, Rainer T1 - In-situ Analytik von organischen Bodenkontaminationen mit Laser-induzierter Fluoreszenz Y1 - 2000 ER - TY - JOUR A1 - Löhmannsröben, Hans-Gerd A1 - Theo, Hengstermann A1 - Lemke, Matthias A1 - Schober, Lars A1 - Schultze, Rainer T1 - Entwicklung eines optischen Meßsystems zur in-situ Bestimmung von Fluoreszenztracern, Sauerstoff und pH- Wert in Gewässern (FLUTRAS: Fluorescence Tracer Detection System) Y1 - 2000 ER - TY - JOUR A1 - Schober, Lars A1 - Löhmannsröben, Hans-Gerd T1 - Determination of optical parameters for light penetration in particulate materials and soils with diffuse reflectance (DR) spectroscopy Y1 - 2000 ER - TY - JOUR A1 - Löhmannsröben, Hans-Gerd T1 - In situ Laser-induced fluorescence (LIF) analysis pf petroleum product-contaminared soil samples Y1 - 2000 ER - TY - JOUR A1 - Haitzer, Markus A1 - Löhmannsröben, Hans-Gerd A1 - Steinberg, Christian E. W. A1 - Zimmermann, Ute T1 - In vivo laser-induced fluorescence detection of pyrene in nematodes and determination of pyrene binding constants for humic substances by fluorescences quenching and bioaccumulation experiments Y1 - 2000 ER - TY - JOUR A1 - Zühlke, Martin A1 - Zenichowski, Karl A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Subambient pressure electrospray ionization ion mobility spectrometry JF - International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry N2 - The pressure dependence of sheath gas assisted electrospray ionization (ESI) was investigated based on two complementary experimental setups, namely an ESI-ion mobility (IM) spectrometer and an ESI capillary - Faraday plate setup housed in an optically accessible vacuum chamber. The ESI-IM spectrometer is capable of working in the pressure range between 300 and 1000 mbar. Another aim was the assessment of the analytical capabilities of a subambient pressure ESI-IM spectrometer. The pressure dependence of ESI was characterized by imaging the electrospray and recording current-voltage (I-U) curves. Qualitatively different behavior was observed in both setups. While the current rises continuously with the voltage in the capillary-plate setup, a sharp increase of the current was measured in the IM spectrometer above a pressure-dependent threshold voltage. The different character can be attributed to the detection of different species in both experiments. In the capillary-plate experiment, a multitude of charged species are detected while only desolvated ions attribute to the IM spectrometer signal. This finding demonstrates the utility of IM spectrometry for the characterization of ESI, since in contrast to the capillary-plate setup, the release of ions from the electrospray droplets can be observed. The I-U curves change significantly with pressure. An important result is the reduction of the maximum current with decreasing pressure. The connected loss of ionization efficiency can be compensated by a more efficient transfer of ions in the IM spectrometer at increased E/N. Thus, similar limits of detection could be obtained at 500 mbar and 1 bar. KW - Ion mobility spectrometry KW - Electrospray ionization KW - Subambient pressure KW - Imaging Y1 - 2017 U6 - https://doi.org/10.1007/s12127-017-0215-x SN - 1435-6163 SN - 1865-4584 VL - 20 SP - 47 EP - 56 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Schmalzlin, E. A1 - van Dongen, J. T. A1 - Klimant, I. A1 - Marmodee, Bettina A1 - Steup, Martin A1 - Fisahn, Joachim A1 - Geigenberger, Peter Ludwig A1 - Löhmannsröben, Hans-Gerd T1 - An optical multifrequency phase-modulation method using microbeads for measuring intracellular oxygen concentrations in plants N2 - A technique has been developed to measure absolute intracellular oxygen concentrations in green plants. Oxygen- sensitive phosphorescent microbeads were injected into the cells and an optical multifrequency phase-modulation technique was used to discriminate the sensor signal from the strong auto fluorescence of the plant tissue. The method was established using photosynthesis- competent cells of the giant algae Chara corallina L., and was validated by application to various cell types of other plant species Y1 - 2005 SN - 0006-3495 ER - TY - JOUR A1 - Zühlke, Martin A1 - Meiling, Till Thomas A1 - Roder, Phillip A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Bald, Ilko A1 - Löhmannsröben, Hans-Gerd A1 - Janßen, Traute A1 - Erhard, Marcel A1 - Repp, Alexander T1 - Photodynamic inactivation of E. coli bacteria via carbon nanodots JF - ACS omega / American Chemical Society N2 - The increasing development of antibiotic resistance in bacteria has been a major problem for years, both in human and veterinary medicine. Prophylactic measures, such as the use of vaccines, are of great importance in reducing the use of antibiotics in livestock. These vaccines are mainly produced based on formaldehyde inactivation. However, the latter damages the recognition elements of the bacterial proteins and thus could reduce the immune response in the animal. An alternative inactivation method developed in this work is based on gentle photodynamic inactivation using carbon nanodots (CNDs) at excitation wavelengths λex > 290 nm. The photodynamic inactivation was characterized on the nonvirulent laboratory strain Escherichia coli K12 using synthesized CNDs. For a gentle inactivation, the CNDs must be absorbed into the cytoplasm of the E. coli cell. Thus, the inactivation through photoinduced formation of reactive oxygen species only takes place inside the bacterium, which means that the outer membrane is neither damaged nor altered. The loading of the CNDs into E. coli was examined using fluorescence microscopy. Complete loading of the bacterial cells could be achieved in less than 10 min. These studies revealed a reversible uptake process allowing the recovery and reuse of the CNDs after irradiation and before the administration of the vaccine. The success of photodynamic inactivation was verified by viability assays on agar. In a homemade flow photoreactor, the fastest successful irradiation of the bacteria could be carried out in 34 s. Therefore, the photodynamic inactivation based on CNDs is very effective. The membrane integrity of the bacteria after irradiation was verified by slide agglutination and atomic force microscopy. The method developed for the laboratory strain E. coli K12 could then be successfully applied to the important avian pathogens Bordetella avium and Ornithobacterium rhinotracheale to aid the development of novel vaccines. KW - Bacteria KW - Genetics KW - Fluorescence KW - Photodynamics KW - Irradiation Y1 - 2021 U6 - https://doi.org/10.1021/acsomega.1c01700 SN - 2470-1343 VL - 6 IS - 37 SP - 23742 EP - 23749 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Andreotti, Sandro A1 - Reinert, Knut A1 - Zenichowski, Karl A1 - Diener, Marc T1 - High-performance liquid chromatography with electrospray ionization ion mobility spectrometry: Characterization, data management, and applications JF - Journal of separation science N2 - The combination of high-performance liquid chromatography and electrospray ionization ion mobility spectrometry facilitates the two-dimensional separation of complex mixtures in the retention and drift time plane. The ion mobility spectrometer presented here was optimized for flow rates customarily used in high-performance liquid chromatography between 100 and 1500 mu L/min. The characterization of the system with respect to such parameters as the peak capacity of each time dimension and of the 2D spectrum was carried out based on a separation of a pesticide mixture containing 24 substances. While the total ion current chromatogram is coarsely resolved, exhibiting coelutions for a number of compounds, all substances can be separately detected in the 2D plane due to the orthogonality of the separations in retention and drift dimensions. Another major advantage of the ion mobility detector is the identification of substances based on their characteristic mobilities. Electrospray ionization allows the detection of substances lacking a chromophore. As an example, the separation of a mixture of 18 amino acids is presented. A software built upon the free mass spectrometry package OpenMS was developed for processing the extensive 2D data. The different processing steps are implemented as separate modules which can be arranged in a graphic workflow facilitating automated processing of data. KW - Amino acids KW - Electrospray ionization KW - Ion mobility spectrometry KW - Pesticides KW - Two-dimensional separations Y1 - 2016 U6 - https://doi.org/10.1002/jssc.201600749 SN - 1615-9306 SN - 1615-9314 VL - 39 SP - 4756 EP - 4764 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Erler, Alexander A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Grothusheitkamp, Daniela A1 - Kunz, Thomas A1 - Methner, Frank-Jürgen T1 - Characterization of volatile metabolites formed by molds on barley by mass and ion mobility spectrometry JF - Journal of mass spectrometr N2 - The contamination of barley by molds on the field or in storage leads to the spoilage of grain and the production of mycotoxins, which causes major economic losses in malting facilities and breweries. Therefore, on-site detection of hidden fungus contaminations in grain storages based on the detection of volatile marker compounds is of high interest. In this work, the volatile metabolites of 10 different fungus species are identified by gas chromatography (GC) combined with two complementary mass spectrometric methods, namely, electron impact (EI) and chemical ionization at atmospheric pressure (APCI)-mass spectrometry (MS). The APCI source utilizes soft X-radiation, which enables the selective protonation of the volatile metabolites largely without side reactions. Nearly 80 volatile or semivolatile compounds from different substance classes, namely, alcohols, aldehydes, ketones, carboxylic acids, esters, substituted aromatic compounds, alkenes, terpenes, oxidized terpenes, sesquiterpenes, and oxidized sesquiterpenes, could be identified. The profiles of volatile and semivolatile metabolites of the different fungus species are characteristic of them and allow their safe differentiation. The application of the same GC parameters and APCI source allows a simple method transfer from MS to ion mobility spectrometry (IMS), which permits on-site analyses of grain stores. Characterization of IMS yields limits of detection very similar to those of APCI-MS. Accordingly, more than 90% of the volatile metabolites found by APCI-MS were also detected in IMS. In addition to different fungus genera, different species of one fungus genus could also be differentiated by GC-IMS. KW - APCI KW - fungus KW - gas chromatography KW - ion mobility spectrometry KW - mass KW - spectrometry KW - mold KW - soft X-ray Y1 - 2020 U6 - https://doi.org/10.1002/jms.4501 SN - 1076-5174 SN - 1096-9888 VL - 55 IS - 5 SP - 1 EP - 10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Hille, Carsten A1 - Berg, Maik A1 - Bressel, Lena A1 - Munzke, Dorit A1 - Primus, Philipp A1 - Löhmannsröben, Hans-Gerd A1 - Dosche, Carsten T1 - Time-domain fluorescence lifetime imaging for intracellular pH sensing in living tissues N2 - pH sensing in living cells represents one of the most prominent topics in biochemistry and physiology. In this study we performed one-photon and two-photon time-domain fluorescence lifetime imaging with a laser-scanning microscope using the time-correlated single-photon counting technique for imaging intracellular pH levels. The suitability of different commercial fluorescence dyes for lifetime-based pH sensing is discussed on the basis of in vitro as well of in situ measurements. Although the tested dyes are suitable for intensity-based ratiometric measurements, for lifetime- based techniques in the time-domain so far only BCECF seems to meet the requirements of reliable intracellular pH recordings in living cells. Y1 - 2008 U6 - https://doi.org/10.1007/s00216-008-2147-0 ER - TY - JOUR A1 - Erler, Alexander A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Gebbers, Robin T1 - Soil Nutrient Detection for Precision Agriculture Using Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and Multivariate Regression Methods (PLSR, Lasso and GPR) JF - Sensors N2 - Precision agriculture (PA) strongly relies on spatially differentiated sensor information. Handheld instruments based on laser-induced breakdown spectroscopy (LIBS) are a promising sensor technique for the in-field determination of various soil parameters. In this work, the potential of handheld LIBS for the determination of the total mass fractions of the major nutrients Ca, K, Mg, N, P and the trace nutrients Mn, Fe was evaluated. Additionally, other soil parameters, such as humus content, soil pH value and plant available P content, were determined. Since the quantification of nutrients by LIBS depends strongly on the soil matrix, various multivariate regression methods were used for calibration and prediction. These include partial least squares regression (PLSR), least absolute shrinkage and selection operator regression (Lasso), and Gaussian process regression (GPR). The best prediction results were obtained for Ca, K, Mg and Fe. The coefficients of determination obtained for other nutrients were smaller. This is due to much lower concentrations in the case of Mn, while the low number of lines and very weak intensities are the reason for the deviation of N and P. Soil parameters that are not directly related to one element, such as pH, could also be predicted. Lasso and GPR yielded slightly better results than PLSR. Additionally, several methods of data pretreatment were investigated. KW - LIBS KW - lasso KW - PLS regression KW - gaussian processes KW - soil KW - precision agriculture KW - nutrients Y1 - 2020 U6 - https://doi.org/10.3390/s20020418 SN - 1424-8220 VL - 20 IS - 2 PB - MDPI CY - Basel ER - TY - JOUR A1 - Erler, Alexander A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Grothusheitkamp, Daniela A1 - Kunz, T. A1 - Methner, Frank-Jürgen T1 - Detection of volatile organic compounds in the headspace above mold fungi by GC-soft X-radiation-based APCI-MS JF - Journal of mass spectrometr N2 - Mold fungi on malting barley grains cause major economic loss in malting and brewery facilities. Possible proxies for their detection are volatile and semivolatile metabolites. Among those substances, characteristic marker compounds have to be identified for a confident detection of mold fungi in varying surroundings. The analytical determination is usually performed through passive sampling with solid phase microextraction, gas chromatographic separation, and detection by electron ionization mass spectrometry (EI-MS), which often does not allow a confident determination due to the absence of molecular ions. An alternative is GC-APCI-MS, generally, allowing the determination of protonated molecular ions. Commercial atmospheric pressure chemical ionization (APCI) sources are based on corona discharges, which are often unspecific due to the occurrence of several side reactions and produce complex product ion spectra. To overcome this issue, an APCI source based on soft X-radiation is used here. This source facilitates a more specific ionization by proton transfer reactions only. In the first part, the APCI source is characterized with representative volatile fungus metabolites. Depending on the proton affinity of the metabolites, the limits of detection are up to 2 orders of magnitude below those of EI-MS. In the second part, the volatile metabolites of the mold fungus species Aspergillus, Alternaria, Fusarium, and Penicillium are investigated. In total, 86 compounds were found with GC-EI/APCI-MS. The metabolites identified belong to the substance classes of alcohols, aldehydes, ketones, carboxylic acids, esters, substituted aromatic compounds, terpenes, and sesquiterpenes. In addition to substances unspecific for the individual fungus species, characteristic patterns of metabolites, allowing their confident discrimination, were found for each of the 4 fungus species. Sixty-seven of the 86 metabolites are detected by X-ray-based APCI-MS alone. The discrimination of the fungus species based on these metabolites alone was possible. Therefore, APCI-MS in combination with collision induced dissociation alone could be used as a supervision method for the detection of mold fungi. KW - APCI KW - gas chromatography KW - mass spectrometry KW - mold fungi KW - soft X-radiation KW - volatile organic compounds Y1 - 2018 U6 - https://doi.org/10.1002/jms.4210 SN - 1076-5174 SN - 1096-9888 VL - 53 IS - 10 SP - 911 EP - 920 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Khadem, S. M. J. A1 - Hille, Carsten A1 - Löhmannsröben, Hans-Gerd A1 - Sokolov, Igor M. T1 - What information is contained in the fluorescence correlation spectroscopy curves, and where JF - Physical review : E, Statistical, nonlinear and soft matter physics Y1 - 2016 U6 - https://doi.org/10.1103/PhysRevE.94.022407 SN - 2470-0045 SN - 2470-0053 VL - 94 PB - American Physical Society CY - College Park ER - TY - JOUR A1 - Khadem, S. M. J. A1 - Hille, Carsten A1 - Löhmannsröben, Hans-Gerd A1 - Sokolov, Igor M. T1 - Spot variation fluorescence correlation spectroscopy by data post-processing JF - Scientific reports N2 - Spot variation fluorescence correlation spectroscopy (SV-FCS) is a variant of the FCS techniques which may give useful information about the structural organisation of the medium in which the diffusion takes place. We show that the same results can be obtained by post-processing the photon count data from ordinary FCS measurements. By using this method, one obtains the fluorescence autocorrelation functions for sizes of confocal volume, which are effectively smaller than that of the initial FCS measurement. The photon counts of the initial experiment are first transformed into smooth intensity trace using kernel smoothing method or to a piecewise-continuous intensity trace using binning and then a non-linear transformation is applied to this trace. The result of this transformation mimics the photon count rate in an experiment performed with a smaller confocal volume. The applicability of the method is established in extensive numerical simulations and directly supported in in-vitro experiments. The procedure is then applied to the diffusion of AlexaFluor647-labeled streptavidin in living cells. Y1 - 2017 U6 - https://doi.org/10.1038/s41598-017-05672-8 SN - 2045-2322 VL - 7 SP - 1 EP - 9 PB - Nature Publ. Group CY - London ER - TY - JOUR A1 - Zakrevskyy, Yuriy A1 - Cywinski, Piotr A1 - Cywinska, Magdalena A1 - Paasche, Jens A1 - Lomadze, Nino A1 - Reich, Oliver A1 - Löhmannsröben, Hans-Gerd A1 - Santer, Svetlana T1 - Interaction of photosensitive surfactant with DNA and poly acrylic acid JF - The journal of chemical physics : bridges a gap between journals of physics and journals of chemistr Y1 - 2014 U6 - https://doi.org/10.1063/1.4862679 SN - 0021-9606 SN - 1089-7690 VL - 140 IS - 4 PB - American Institute of Physics CY - Melville ER - TY - JOUR A1 - Schwarze, Thomas A1 - Mickler, Wulfhard A1 - Dosche, Carsten A1 - Flehr, Roman A1 - Klamroth, Tillmann A1 - Löhmannsröben, Hans-Gerd A1 - Saalfrank, Peter A1 - Holdt, Hans-Jürgen T1 - Systematic investigation of photoinduced electron transfer controlled by internal charge transfer and its consequences for selective PdCl2 coordination N2 - Fluoroionophores of fluorophore-spacer-receptor format were prepared for detection of PdCl2 by fluorescence enhancement. The fluorophore probes 1-13 consist of a fluorophore group, in alkyl spacer and a dithiomaleonitrile PdCl2 receptor. First, varying the length of the alkylene spacer (compounds 1-3) revealed, dominant through-space pathway for oxidative photoinduced electron transfer (PET) in CH2-bridged dithiomaleonitrile fluoroionophores. Second. fluorescent probes 4-9 containing two anthracene or pyrene fragments connected through CH2 bridges to the dithiomaleonitrile unit were synthesized. Modulation of the oxidation potential (E-Ox) through electron-withdrawing or -donating groups on the anthracene moiety regulates file thermodynamic driving force for oxidative PET (Delta G(PET)) in bis(anthrylmethylthio)maleonitriles and therefore the fluorescence quantum yields (Phi(f)), too. The new concept was confirmed and transferred to pyrenyl ligands, and fluorescence enhancements (FE) greater than 3.2 in the presence of PdCl2 were achieved by 7 and 8 (FE=5.4 and 5.2). Finally, for comparison, monofluorophore ligands 10-13 were synthesized. Y1 - 2010 UR - http://onlinelibrary.wiley.com/doi/10.1002/chem.200902281/pdf U6 - https://doi.org/10.1002/chem.200902281 SN - 0947-6539 ER - TY - JOUR A1 - Schwarze, Thomas A1 - Mickler, Wulfhard A1 - Dosche, Carsten A1 - Flehr, Roman A1 - Klamroth, Tillmann A1 - Löhmannsröben, Hans-Gerd A1 - Saalfrank, Peter A1 - Holdt, Hans-Jürgen T1 - Systematic investigation of photoinduced electron transfer controlled by internal charge transfer and its consequences for selective PdCl2 coordination N2 - Fluoroionophores of fluorophore-spacer-receptor format were prepared for detection of PdCl2 by fluorescence enhancement. The fluorescent probes 1-13 consist of a fluorophore group, an alkyl spacer and a dithiomaleonitrile PdCl2 receptor. First, varying the length of the alkylene spacer (compounds 1-3) revealed a dominant through-space pathway for oxidative photoinduced electron transfer (PET) in CH2-bridged dithiomaleonitrile fluoroionophores. Second, fluorescent probes 4-9 containing two anthracene or pyrene fragments connected through CH2 bridges to the dithiomaleonitrile unit were synthesized. Modulation of the oxidation potential (EOx) through electron-withdrawing or -donating groups on the anthracene moiety regulates the thermodynamic driving force for oxidative PET (GPET) in bis(anthrylmethylthio)maleonitriles and therefore the fluorescence quantum yields (f), too. The new concept was confirmed and transferred to pyrenyl ligands, and fluorescence enhancements (FE) greater than 3.2 in the presence of PdCl2 were achieved by 7 and 8 (FE=5.4 and 5.2). Finally, for comparison, monofluorophore ligands 10-13 were synthesized. Y1 - 2010 UR - http://www3.interscience.wiley.com/journal/26293/home SN - 0947-6539 ER - TY - JOUR A1 - Schwarze, Thomas A1 - Dosche, Carsten A1 - Flehr, Roman A1 - Klamroth, Tillmann A1 - Löhmannsröben, Hans-Gerd A1 - Saalfrank, Peter A1 - Cleve, Ernst A1 - Buschmann, Hans-Jürgen A1 - Holdt, Hans-Jürgen T1 - Combination of a CT modulated PET and an intramolecular excimer formation to quantify PdCl2 by large fluorescence enhancement N2 - The [6.6](9,10)anthracenophane 1 (Scheme 1) is a selective fluoroionophore for the detection of PdCl2 with a large fluorescence enhancement factor (I/I-0 > 250). Y1 - 2010 UR - http://pubs.rsc.org/en/content/articlehtml/2010/cc/b919973j U6 - https://doi.org/10.1039/B919973j SN - 1359-7345 ER - TY - JOUR A1 - Schwarze, Thomas A1 - Dosche, Carsten A1 - Flehr, Roman A1 - Klamroth, Tillmann A1 - Löhmannsröben, Hans-Gerd A1 - Saalfrank, Peter A1 - Cleve, Ernst A1 - Buschmann, Hans-Jürgen A1 - Holdt, Hans-Jürgen T1 - Combination of a CT modulated PET and an intramolecular excimer formation to quantify PdCl2 by large fluorescence enhancement Y1 - 2010 UR - http://www.rsc.org/ej/CC/2010/b919973j.pdf SN - 1359-7345 ER - TY - JOUR A1 - Schirmack, Janosch A1 - Boehm, Michael A1 - Brauer, Chris A1 - Löhmannsröben, Hans-Gerd A1 - de Vera, Jean-Pierre Paul A1 - Moehlmann, Diedrich A1 - Wagner, Dirk T1 - Laser spectroscopic real time measurements of methanogenic activity under simulated Martian subsurface analog conditions JF - Planetary and space science N2 - On Earth, chemolithoautothrophic and anaerobic microorganisms such as methanogenic archaea are regarded as model organisms for possible subsurface life on Mars. For this reason, the methanogenic strain Methanosarcina soligelidi (formerly called Methanosarcina spec. SMA-21), isolated from permafrost-affected soil in northeast Siberia, has been tested under Martian thermo-physical conditions. In previous studies under simulated Martian conditions, high survival rates of these microorganisms were observed. In our study we present a method to measure methane production as a first attempt to study metabolic activity of methanogenic archaea during simulated conditions approaching conditions of Mars-like environments. To determine methanogenic activity, a measurement technique which is capable to measure the produced methane concentration with high precision and with high temporal resolution is needed. Although there are several methods to detect methane, only a few fulfill all the needed requirements to work within simulated extraterrestrial environments. We have chosen laser spectroscopy, which is a non-destructive technique that measures the methane concentration without sample taking and also can be run continuously. In our simulation, we detected methane production at temperatures down to -5 degrees C, which would be found on Mars either temporarily in the shallow subsurface or continually in the deep subsurface. The pressure of 50 kPa which we used in our experiments, corresponds to the expected pressure in the Martian near subsurface. Our new device proved to be fully functional and the results indicate that the possible existence of methanogenic archaea in Martian subsurface habitats cannot be ruled out. (C) 2013 Published by Elsevier Ltd. KW - Mars KW - Methanogens KW - Methane KW - Sub-zero temperature (Celsius) KW - Wavelength modulation spectroscopy (laser spectroscopy) Y1 - 2014 U6 - https://doi.org/10.1016/j.pss.2013.08.019 SN - 0032-0633 VL - 98 SP - 198 EP - 204 PB - Elsevier CY - Oxford ER -