TY - JOUR A1 - Ellis, S. C. A1 - Bland-Hawthorn, Joss A1 - Lawrence, J. A1 - Horton, A. J. A1 - Trinh, C. A1 - Leon-Saval, S. G. A1 - Shortridge, K. A1 - Bryant, J. A1 - Case, S. A1 - Colless, M. A1 - Couch, W. A1 - Freeman, K. A1 - Gers, L. A1 - Glazebrook, K. A1 - Haynes, R. A1 - Lee, S. A1 - Löhmannsröben, Hans-Gerd A1 - O'Byrne, J. A1 - Miziarski, S. A1 - Roth, M. A1 - Schmidt, B. A1 - Tinney, C. G. A1 - Zheng, J. T1 - Suppression of the near-infrared OH night-sky lines with fibre Bragg gratings - first results JF - Monthly notices of the Royal Astronomical Society N2 - The background noise between 1 and 1.8 ?mu m in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, the Gemini Near-infrared OH Suppression Integral Field Unit (IFU) System (GNOSIS), which suppresses 103 OH doublets between 1.47 and 1.7?mu m by a factor of 1000 with a resolving power of 10?000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph at the Anglo-Australian Telescope. We present measurements of sensitivity, background and throughput. The combined throughput of the GNOSIS fore-optics, grating unit and relay optics is 36?per cent, but this could be improved to 46?per cent with a more optimal design. We measure strong suppression of the OH lines, confirming that OH suppression with fibre Bragg gratings will be a powerful technology for low-resolution spectroscopy. The integrated OH suppressed background between 1.5 and 1.7 mu m is reduced by a factor of 9 compared to a control spectrum using the same system without suppression. The potential of low-resolution OH-suppressed spectroscopy is illustrated with example observations of Seyfert galaxies and a low-mass star. The GNOSIS background is dominated by detector dark current below 1.67 mu m and by thermal emission above 1.67 mu m. After subtracting these, we detect an unidentified residual interline component of 860 +/- 210 photons s-1 m-2?arcsec-2?mu m-1, comparable to previous measurements. This component is equally bright in the suppressed and control spectra. We have investigated the possible source of the interline component, but were unable to discriminate between a possible instrumental artefact and intrinsic atmospheric emission. Resolving the source of this emission is crucial for the design of fully optimized OH suppression spectrographs. The next-generation OH suppression spectrograph will be focused on resolving the source of the interline component, taking advantage of better optimization for a fibre Bragg grating feed incorporating refinements of design based on our findings from GNOSIS. We quantify the necessary improvements for an optimal OH suppressing fibre spectrograph design. KW - atmospheric effects KW - instrumentation: miscellaneous KW - infrared: general Y1 - 2012 U6 - https://doi.org/10.1111/j.1365-2966.2012.21602.x SN - 0035-8711 VL - 425 IS - 3 SP - 1682 EP - 1695 PB - Wiley-Blackwell CY - Hoboken ER - TY - GEN A1 - Dosche, Carsten A1 - Kumke, Michael Uwe A1 - Ariese, F. A1 - Bader, Arjen N. A1 - Gooijer, C. A1 - Dosa, P. I. A1 - Han, S. A1 - Miljanic, O. S. A1 - Vollhardt, K. Peter C. A1 - Puchta, R. A1 - Eikema Hommes, N. J. R. van T1 - Shpol’skii spectroscopy and vibrational analysis of [N]phenylenes N2 - Vibrationally resolved fluorescence spectra of four angular [N]phenylenes were recorded with laser excited Shpol’skii spectroscopy (LESS) in an n-octane matrix at 10 K. In general, the same vibrational frequencies were observed in the fluorescence excitation and emission spectra, indicating that the geometries of ground and electronically excited state are very similar. Because of intensity borrowing from the S2 state, vibrations of two different symmetries were observed in the fluorescence excitation spectra of angular [3]phenylene and zig-zag[5]phenylene. This finding allowed the location of the S2 state for these compounds. DFT calculations(RB3LYP/6-31G*) of the ground state vibrational frequencies were made. The calculated vibrational modes were in reasonably good agreement with the experimental data. A new very low-frequency vibration of approximately 100 cm-1 was predicted and experimentally confirmed for all [N]phenylenes investigated. This vibration seems to be unique for [N]phenylenes and is attributed to an in-plane movement of the carbon backbone. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - paper 024 Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus-13075 ER - TY - GEN A1 - Dosche, Carsten A1 - Kumke, Michael Uwe A1 - Löhmannsröben, Hans-Gerd A1 - Ariese, F. A1 - Bader, Arjen N. A1 - Gooijer, C. A1 - Miljanic, O. S. A1 - Iwamoto, M. A1 - Vollhardt, K. Peter C. A1 - Puchta, R. ; van Eikema Hommes, N. J. R. T1 - Deuteration effects on the vibronic structure of the fluorescence spectra and the internal conversion rates of triangular [4]Phenylene N2 - Deuteration effects on the vibronic structure of the emission and excitation spectra of triangular [4]phenylene (D3h[4]phenylene) were studied using laser-excited Shpolskii spectroscopy (LESS) in an octane matrix at 4.2 K. For correct assignment of the vibrational modes, the experimental results were compared with calculated frequencies (B3LYP/6-31G*). CH vibrations were identified by their characteristic isotopic shifts in the spectra of deuterated triangular [4]phenylenes. Two CC stretching modes, at 100 cm–1 and 1176 cm–1, suitable as probes for bond strength changes in the excited state, were identified. The isotope effect on the internal conversion rates of triangular [4]phenylene was evaluated from measurements of temperature dependent lifetime. Isotope dependency and the magnitude of the internal conversion rates indicate that internal conversion in triangular [4]phenylene is most likely induced by CH vibrations. The results obtained by LESS and lifetime measurements were compared with PM3 PECI calculations of the excited state structure. The theoretical results and the relation between ground and excited state vibration energies of the 1176 cm–1 probe vibration indicate a reduction of bond alternation of the central cyclohexatriene ring in the excited state. T3 - Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe - paper 002 Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus-11881 ER - TY - GEN A1 - Ellis, S. C. A1 - Bauer, S. A1 - Bacigalupo, C. A1 - Bland-Hawthorn, J. A1 - Bryant, J. J. A1 - Case, S. A1 - Content, R. A1 - Fechner, T. A1 - Giannone, D. A1 - Haynes, R. A1 - Hernandez, E. A1 - Horton, A. J. A1 - Klauser, U. A1 - Lawrence, J. S. A1 - Leon-Saval, S. G. A1 - Lindley, E. A1 - Löhmannsröben, Hans-Gerd A1 - Min, S. -S. A1 - Pai, N. A1 - Roth, M. A1 - Shortridge, K. A1 - Waller, L. A1 - Xavier, Pascal A1 - Zhelem, Ross T1 - PRAXIS: an OH suppression optimised near infrared spectrograph T2 - Ground-based and Airborne Instrumentation for Astronomy VII N2 - The problem of atmospheric emission from OH molecules is a long standing problem for near-infrared astronomy. PRAXIS is a unique spectrograph which is fed by fibres that remove the OH background and is optimised specifically to benefit from OH-Suppression. The OH suppression is achieved with fibre Bragg gratings, which were tested successfully on the GNOSIS instrument. PRAXIS uses the same fibre Bragg gratings as GNOSIS in its first implementation, and will exploit new, cheaper and more efficient, multicore fibre Bragg gratings in the second implementation. The OH lines are suppressed by a factor of similar to 1000, and the expected increase in the signal-to-noise in the interline regions compared to GNOSIS is a factor of similar to 9 with the GNOSIS gratings and a factor of similar to 17 with the new gratings. PRAXIS will enable the full exploitation of OH suppression for the first time, which was not achieved by GNOSIS (a retrofit to an existing instrument that was not OH-Suppression optimised) due to high thermal emission, low spectrograph transmission and detector noise. PRAXIS has extremely low thermal emission, through the cooling of all significantly emitting parts, including the fore-optics, the fibre Bragg gratings, a long length of fibre, and the fibre slit, and an optical design that minimises leaks of thermal emission from outside the spectrograph. PRAXIS has low detector noise through the use of a Hawaii-2RG detector, and a high throughput through a efficient VPH based spectrograph. PRAXIS will determine the absolute level of the interline continuum and enable observations of individual objects via an IFU. In this paper we give a status update and report on acceptance tests. KW - Near infrared KW - spectroscopy KW - OH suppression KW - astrophotonics KW - fibre Bragg gratings Y1 - 2018 SN - 978-1-5106-1958-6 U6 - https://doi.org/10.1117/12.2311898 SN - 0277-786X SN - 1996-756X VL - 10702 PB - SPIE-INT Soc Optical Engineering CY - Bellingham ER - TY - JOUR A1 - Sangoro, Joshia R. A1 - Iacob, C. A1 - Agapov, A. L. A1 - Wang, Yangyang A1 - Berdzinski, Stefan A1 - Rexhausen, Hans A1 - Strehmel, Veronika A1 - Friedrich, C. A1 - Sokolov, A. P. A1 - Kremer, F. T1 - Decoupling of ionic conductivity from structural dynamics in polymerized ionic liquids JF - Soft matter N2 - Charge transport and structural dynamics in low molecular weight and polymerized 1-vinyl-3-pentylimidazolium bis(trifluoromethylsulfonyl) imide ionic liquids (ILs) are investigated by a combination of broadband dielectric spectroscopy, dynamic mechanical spectroscopy and differential scanning calorimetry. While the dc conductivity and fluidity exhibit practically identical temperature dependence for the non-polymerized IL, a significant decoupling of ionic conduction from structural dynamics is observed for the polymerized IL. In addition, the dc conductivity of the polymerized IL exceeds that of its molecular counterpart by four orders of magnitude at their respective calorimetric glass transition temperatures. This is attributed to the unusually high mobility of the anions especially at lower temperatures when the structural dynamics is significantly slowed down. A simple physical explanation of the possible origin of the remarkable decoupling of ionic conductivity from structural dynamics is proposed. Y1 - 2014 U6 - https://doi.org/10.1039/c3sm53202j SN - 1744-683X SN - 1744-6848 VL - 10 IS - 20 SP - 3536 EP - 3540 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Bland-Hawthorn, Joss A1 - Ellis, S. C. A1 - Leon-Saval, S. G. A1 - Haynes, R. A1 - Roth, Martin M. A1 - Löhmannsröben, Hans-Gerd A1 - Horton, A. J. A1 - Cuby, J. -G. A1 - Birks, T. A. A1 - Lawrence, J. S. A1 - Gillingham, P. A1 - Ryder, S. D. A1 - Trinh, C. T1 - A complex multi-notch astronomical filter to suppress the bright infrared sky JF - Nature Communications N2 - A long-standing and profound problem in astronomy is the difficulty in obtaining deep near-infrared observations due to the extreme brightness and variability of the night sky at these wavelengths. A solution to this problem is crucial if we are to obtain the deepest possible observations of the early Universe, as redshifted starlight from distant galaxies appears at these wavelengths. The atmospheric emission between 1,000 and 1,800 nm arises almost entirely from a forest of extremely bright, very narrow hydroxyl emission lines that varies on timescales of minutes. The astronomical community has long envisaged the prospect of selectively removing these lines, while retaining high throughput between them. Here we demonstrate such a filter for the first time, presenting results from the first on-sky tests. Its use on current 8 m telescopes and future 30 m telescopes will open up many new research avenues in the years to come. Y1 - 2011 U6 - https://doi.org/10.1038/ncomms1584 SN - 2041-1723 VL - 2 IS - 50 PB - Nature Publ. Group CY - London ER - TY - JOUR A1 - Bartlett, Nate C. -M. A1 - Jankunas, Justin A1 - Goswami, Tapas A1 - Zare, Richard N. A1 - Bouakline, Foudhil A1 - Althorpe, Stuart C. T1 - Differential cross sections for H + D-2 -> HD(v '=2, j '=0,3,6,9) + D at center-of-mass collision energies of 1.25, 1.61, and 1.97 eV JF - Physical chemistry, chemical physics : a journal of European Chemical Societies N2 - We have measured differential cross sections (DCSs) for the reaction H + D-2 -> HD- (v' = 2, j' = 0,3,6,9) + D at center-of-mass collision energies E-coll of 1.25, 1.61, and 1.97 eV using the photoloc technique. The DCSs show a strong dependence on the product rotational quantum number. For the HD(v' = 2, j' = 0) product, the DCS is bimodal but becomes oscillatory as the collision energy is increased. For the other product states, they are dominated by a single peak, which shifts from back to sideward scattering as j' increases, and they are in general less sensitive to changes in the collision energy. The experimental results are compared to quantum mechanical calculations and show good, but not fully quantitative agreement. Y1 - 2011 U6 - https://doi.org/10.1039/c0cp02460k SN - 1463-9076 VL - 13 IS - 18 SP - 8175 EP - 8179 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Soliveres, Santiago A1 - Manning, Peter A1 - Prati, Daniel A1 - Gossner, Martin M. A1 - Alt, Fabian A1 - Arndt, Hartmut A1 - Baumgartner, Vanessa A1 - Binkenstein, Julia A1 - Birkhofer, Klaus A1 - Blaser, Stefan A1 - Bluethgen, Nico A1 - Boch, Steffen A1 - Boehm, Stefan A1 - Boerschig, Carmen A1 - Buscot, Francois A1 - Diekoetter, Tim A1 - Heinze, Johannes A1 - Hoelzel, Norbert A1 - Jung, Kirsten A1 - Klaus, Valentin H. A1 - Klein, Alexandra-Maria A1 - Kleinebecker, Till A1 - Klemmer, Sandra A1 - Krauss, Jochen A1 - Lange, Markus A1 - Morris, E. Kathryn A1 - Mueller, Joerg A1 - Oelmann, Yvonne A1 - Overmann, Jörg A1 - Pasalic, Esther A1 - Renner, Swen C. A1 - Rillig, Matthias C. A1 - Schaefer, H. Martin A1 - Schloter, Michael A1 - Schmitt, Barbara A1 - Schoening, Ingo A1 - Schrumpf, Marion A1 - Sikorski, Johannes A1 - Socher, Stephanie A. A1 - Solly, Emily F. A1 - Sonnemann, Ilja A1 - Sorkau, Elisabeth A1 - Steckel, Juliane A1 - Steffan-Dewenter, Ingolf A1 - Stempfhuber, Barbara A1 - Tschapka, Marco A1 - Tuerke, Manfred A1 - Venter, Paul A1 - Weiner, Christiane N. A1 - Weisser, Wolfgang W. A1 - Werner, Michael A1 - Westphal, Catrin A1 - Wilcke, Wolfgang A1 - Wolters, Volkmar A1 - Wubet, Tesfaye A1 - Wurst, Susanne A1 - Fischer, Markus A1 - Allan, Eric T1 - Locally rare species influence grassland ecosystem multifunctionality JF - Philosophical transactions of the Royal Society of London : B, Biological sciences N2 - Species diversity promotes the delivery of multiple ecosystem functions (multifunctionality). However, the relative functional importance of rare and common species in driving the biodiversity multifunctionality relationship remains unknown. We studied the relationship between the diversity of rare and common species (according to their local abundances and across nine different trophic groups), and multifunctionality indices derived from 14 ecosystem functions on 150 grasslands across a land use intensity (LUI) gradient. The diversity of above- and below-ground rare species had opposite effects, with rare above-ground species being associated with high levels of multifunctionality, probably because their effects on different functions did not trade off against each other. Conversely, common species were only related to average, not high, levels of multifunctionality, and their functional effects declined with LUI. Apart from the community level effects of diversity, we found significant positive associations between the abundance of individual species and multifunctionality in 6% of the species tested. Species specific functional effects were best predicted by their response to LUI: species that declined in abundance with land use intensification were those associated with higher levels of multifunctionality. Our results highlight the importance of rare species for ecosystem multifunctionality and help guiding future conservation priorities. KW - biodiversity KW - common species KW - ecosystem function KW - identity hypothesis KW - land use KW - multitrophic Y1 - 2016 U6 - https://doi.org/10.1098/rstb.2015.0269 SN - 0962-8436 SN - 1471-2970 VL - 371 SP - 3175 EP - 3185 PB - Royal Society CY - London ER - TY - JOUR A1 - Lendlein, Andreas A1 - Balk, Maria A1 - Tarazona, Natalia A. A1 - Gould, Oliver E. C. T1 - Bioperspectives for Shape-Memory Polymers as Shape Programmable, Active Materials JF - Biomacromolecules : an interdisciplinary journal focused at the interface of polymer science and the biological sciences N2 - Within the natural world, organisms use information stored in their material structure to generate a physical response to a wide variety of environmental changes. The ability to program synthetic materials to intrinsically respond to environmental changes in a similar manner has the potential to revolutionize material science. By designing polymeric devices capable of responsively changing shape or behavior based on information encoded into their structure, we can create functional physical behavior, including a shape memory and an actuation capability. Here we highlight the stimuli-responsiveness and shape-changing ability of biological materials and biopolymer-based materials, plus their potential biomedical application, providing a bioperspective on shape-memory materials. We address strategies to incorporate a shape memory (actuation) function in polymeric materials, conceptualized in terms of its relationship with inputs (environmental stimuli) and outputs (shape change). Challenges and opportunities associated with the integration of several functions in a single material body to achieve multifunctionality are discussed. Finally, we describe how elements that sense, convert, and transmit stimuli have been used to create multisensitive materials. Y1 - 2019 U6 - https://doi.org/10.1021/acs.biomac.9b01074 SN - 1525-7797 SN - 1526-4602 VL - 20 IS - 10 SP - 3627 EP - 3640 PB - American Chemical Society CY - Washington ER - TY - JOUR A1 - Guha, S. A1 - Warsinke, A. A1 - Tientcheu, Ch. M. A1 - Schmalz, K. A1 - Meliani, C. A1 - Wenger, Ch. T1 - Label free sensing of creatinine using a 6 GHz CMOS near-field dielectric immunosensor JF - The analyst : the analytical journal of the Royal Society of Chemistry N2 - In this work we present a CMOS high frequency direct immunosensor operating at 6 GHz (C-band) for label free determination of creatinine. The sensor is fabricated in standard 0.13 μm SiGe:C BiCMOS process. The report also demonstrates the ability to immobilize creatinine molecules on a Si3N4 passivation layer of the standard BiCMOS/CMOS process, therefore, evading any further need of cumbersome post processing of the fabricated sensor chip. The sensor is based on capacitive detection of the amount of non-creatinine bound antibodies binding to an immobilized creatinine layer on the passivated sensor. The chip bound antibody amount in turn corresponds indirectly to the creatinine concentration used in the incubation phase. The determination of creatinine in the concentration range of 0.88–880 μM is successfully demonstrated in this work. A sensitivity of 35 MHz/10 fold increase in creatinine concentration (during incubation) at the centre frequency of 6 GHz is gained by the immunosensor. The results are compared with a standard optical measurement technique and the dynamic range and sensitivity is of the order of the established optical indication technique. The C-band immunosensor chip comprising an area of 0.3 mm2 reduces the sensing area considerably, therefore, requiring a sample volume as low as 2 μl. The small analyte sample volume and label free approach also reduce the experimental costs in addition to the low fabrication costs offered by the batch fabrication technique of CMOS/BiCMOS process. Y1 - 2015 U6 - https://doi.org/10.1039/c4an02194k SN - 0003-2654 SN - 1364-5528 VL - 9 IS - 140 SP - 3019 EP - 3027 PB - Royal Society of Chemistry CY - Cambridge ER -