TY - JOUR A1 - Rector, Michael V. A1 - Intziegianni, Konstantina A1 - Müller, Steffen A1 - Mayer, Frank A1 - Cassel, Michael T1 - Reproducibility of an ankle joint rotation correction method for assessment of Achilles tendon elongation JF - Isokinetics and exercise science : official journal of the European Isokinetic Society N2 - BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly. KW - Ultrasonography KW - Achilles tendon KW - reproducibility KW - isokinetic KW - ankle joint rotation Y1 - 2017 U6 - https://doi.org/10.3233/IES-160644 SN - 0959-3020 SN - 1878-5913 VL - 25 IS - 1 SP - 47 EP - 52 PB - IOS Press CY - Amsterdam ER - TY - GEN A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Risch, Lucie A1 - Müller, Steffen A1 - Engel, Tilman A1 - Mayer, Frank T1 - Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes BT - A Longitudinal Study N2 - Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 355 KW - Achilles and patellar tendon KW - non-athletes KW - sonography KW - training adaptation KW - young athletes Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-403823 ER - TY - JOUR A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Risch, Lucie A1 - Mueller, Steffen A1 - Engel, Tilman A1 - Mayer, Frank T1 - Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes: A Longitudinal Study JF - Frontiers in physiology N2 - Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 +/- 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean SD) and statistical testing for group differences was performed (cy = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 +/- 0.7 mm/5.6 +/- 0.7 mm) nor in controls (4.8 +/- 0.4 mm/4.9 +/- 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (Ml: 3.5 +/- 0.5 mm, M2: 3.8 +/- 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p <= 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports. KW - Achilles and patellar tendon KW - training adaptation KW - sonography KW - young athletes KW - non-athletes Y1 - 2017 U6 - https://doi.org/10.3389/fphys.2017.00795 SN - 1664-042X VL - 8 SP - 599 EP - 611 PB - Frontiers Research Foundation CY - Lausanne ER - TY - JOUR A1 - König, Niklas A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Mayer, Frank T1 - Inter-rater reliability and measurement error of sonographic muscle architecture assessments JF - Journal of ultrasound in medicine N2 - Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation. Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm. Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position. KW - gastrocnemius muscle KW - inter-rater variability KW - muscle architecture KW - musculoskeletal ultrasound KW - sonography Y1 - 2014 U6 - https://doi.org/10.7863/ultra.33.5.769 SN - 0278-4297 SN - 1550-9613 VL - 33 IS - 5 SP - 769 EP - 777 PB - American Institute of Ultrasound in Medicine CY - Laurel ER - TY - CHAP A1 - Intziegianni, Konstantina A1 - Cassel, Michael A1 - König, Niklas A1 - Mayer, Frank T1 - Reliability of variables defining mechanical and material properties of the achilles tendon T2 - Medicine and science in sports and exercise : official journal of the American College of Sports Medicine Y1 - 2013 SN - 0195-9131 SN - 1530-0315 VL - 45 IS - 5 SP - 238 EP - 239 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - CHAP A1 - Intziegianni, Konstantina A1 - Cassel, Michael A1 - Müller, Steffen A1 - Mayer, Frank T1 - Ultrasound evaluation of the patellar tendon cross-sectional area and its relation to maximum force T2 - Medicine and science in sports and exercise : official journal of the American College of Sports Medicine Y1 - 2012 SN - 0195-9131 VL - 44 SP - 714 EP - 714 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - CHAP A1 - Hain, Gerrit A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Mayer, Frank T1 - Achilles tendon cross-sectional area changes during maximal voluntary isometric plantar-flexion contraction in healthy individuals. T2 - Medicine and science in sports and exercise : official journal of the American College of Sports Medicine Y1 - 2014 SN - 0195-9131 SN - 1530-0315 VL - 46 IS - 5 SP - 47 EP - 47 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - CHAP A1 - Intziegianni, Konstantina A1 - Cassel, Michael A1 - Hain, Gerrit A1 - Fröhlic, Katja A1 - Mayer, Frank T1 - Reliability of sonographic assessment of Achilles tendon cross-sectional area at rest and maximal voluntary contraction T2 - Medicine and science in sports and exercise : official journal of the American College of Sports Medicine Y1 - 2014 SN - 0195-9131 SN - 1530-0315 VL - 46 IS - 5 SP - 47 EP - 47 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - CHAP A1 - Risch, Lucie A1 - Cassel, Michael A1 - Messerschmidt, Janin A1 - Intziegianni, Konstantina A1 - Mayer, Frank T1 - Consistency and reliability of examining intratendinous blood flow in Achilles tendinopathy patients using doppler ultrasonography T2 - Medicine and science in sports and exercise : official journal of the American College of Sports Medicine Y1 - 2014 SN - 0195-9131 SN - 1530-0315 VL - 46 IS - 5 SP - 46 EP - 46 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - CHAP A1 - Reschke, Antje A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Mayer, Frank T1 - Intra- and inter-rater reliability of sonographic cross-sectional area measurements in asymptomatic patella tendons T2 - Medicine and science in sports and exercise : official journal of the American College of Sports Medicine Y1 - 2014 SN - 0195-9131 SN - 1530-0315 VL - 46 IS - 5 SP - 927 EP - 928 PB - Lippincott Williams & Wilkins CY - Philadelphia ER -