TY - JOUR A1 - Wochatz, Monique A1 - Rabe, Sophie A1 - Wolter, Martin A1 - Engel, Tilman A1 - Mueller, Steffen A1 - Mayer, Frank T1 - Reproducibility of scapular muscle activity in isokinetic shoulder flexion and extension JF - Journal of electromyography and kinesiology N2 - Repetitive overhead movements have been identified as a main risk factor to develop shoulder complaints with scapular muscle activity being altered. Reliable assessment of muscle activity is essential to differentiate between symptomatic and asymptomatic individuals. Therefore, the present study aimed to investigate the intra-and inter-session reliability of scapular muscle activity during maximal isokinetic shoulder flexion and extension. Eleven asymptomatic adults performed maximum effort isokinetic shoulder flexion and extension (concentric and eccentric at 60 degrees/s) in a test-retest design. Muscle activity of the upper and lower trapezius and serratus anterior was assessed by sEMG. Root Mean Square was calculated for whole ROM and single movement phases of absolute and normalized muscle activity. Absolute (Bland-Altman analysis (Bias, LoA), Minimal detectable change (MDC)) and relative reliability parameters (Intraclass correlation coefficient (ICC), coefficient of variation (CV)/test-retest variability (TRV)) were utilized for the evaluation of reproducibility. Intra-session reliability revealed ICCs between 0.56 and 0.98, averaged CVs of 18% and average MDCs of 81 mV. Inter-session reliability resulted in ICCs between 0.13 and 0.93, averaged TRVs of 21%, average MDCs of 15% and systematic and random error between -8 +/- 60% and 12 +/- 36%. Scapular muscle activity assessed in overhead movements can be measured reliably under maximum load conditions, though variability is dependent on the movement phase. Measurement variability does not exceed magnitudes of altered scapular muscle activities as reported in previous studies. Therefore, maximum load application is a promising approach for the evaluation of changes in scapular control related to pathologies. (C) 2017 Elsevier Ltd. All rights reserved. Y1 - 2017 U6 - https://doi.org/10.1016/j.jelekin.2017.04.006 SN - 1050-6411 SN - 1873-5711 VL - 34 SP - 86 EP - 92 PB - Elsevier CY - Oxford ER - TY - JOUR A1 - Wochatz, Monique A1 - Rabe, Sophie A1 - Wolter, Martin A1 - Engel, Tilman A1 - Mueller, Steffen A1 - Mayer, Frank T1 - Muscle activity of upper and lower trapezius and serratus anterior during unloaded and maximal loaded shoulder flexion and extension JF - International Biomechanics N2 - Altered scapular muscle activity is mostly described under unloaded and submaximal loaded conditions in impingement patients. However, there is no clear evidence on muscle activity with respect to movement phases under maximum load in healthy subjects. Therefore, this study aimed to investigate scapular muscle activity under unloaded and maximum loaded isokinetic shoulder flexion and extension in regard to the movement phase. Fourteen adults performed unloaded (continuous passive motion [CPM]) as well as maximum loaded (concentric [CON], eccentric [ECC]) isokinetic shoulder flexion (Flex) and extension (Ext). Simultaneously, scapular muscle activity was measured by EMG. Root mean square was calculated for the whole ROM and four movement phases. Data were analyzed descriptively and by two-way repeated measures ANOVA. CPMFlex resulted in a linear increase of muscle activity for all muscles. Muscle activity during CONFlex and ECCFlex resulted in either constant activity levels or in an initial increase followed by a plateau in the second half of movement. CPMExt decreased with the progression of movement, whereas CONExt and ECCExt initially decreased and either levelled off or increased in the second half of movement. Scapular muscle activity of unloaded shoulder flexion and extension changed under maximum load showing increased activity levels and an altered pattern over the course of movement. KW - shoulder KW - scapular muscle activity KW - isokinetic testing KW - electromyography Y1 - 2017 U6 - https://doi.org/https://doi.org/10.1080/23335432.2017.1364668 VL - 4 IS - 2 SP - 68 EP - 76 PB - Elsevier CY - Amsterdam ER - TY - GEN A1 - Wippert, Pia-Maria A1 - Puschmann, Anne-Katrin A1 - Drießlein, David A1 - Arampatzis, Adamantios A1 - Banzer, Winfried A1 - Beck, Heidrun A1 - Schiltenwolf, Marcus A1 - Schmidt, Hendrik A1 - Schneider, Christian A1 - Mayer, Frank T1 - Development of a risk stratification and prevention index for stratified care in chronic low back pain. Focus: yellow flags (MiSpEx network) N2 - Introduction: Chronic low back pain (LBP) is a major cause of disability; early diagnosis and stratification of care remain challenges. Objectives: This article describes the development of a screening tool for the 1-year prognosis of patients with high chronic LBP risk (risk stratification index) and for treatment allocation according to treatment-modifiable yellow flag indicators (risk prevention indices, RPI-S). Methods: Screening tools were derived from a multicentre longitudinal study (n = 1071, age >18, intermittent LBP). The greatest prognostic predictors of 4 flag domains ("pain," "distress," "social-environment," "medical care-environment") were determined using least absolute shrinkage and selection operator regression analysis. Internal validity and prognosis error were evaluated after 1-year follow-up. Receiver operating characteristic curves for discrimination (area under the curve) and cutoff values were determined. Results: The risk stratification index identified persons with increased risk of chronic LBP and accurately estimated expected pain intensity and disability on the Pain Grade Questionnaire (0-100 points) up to 1 year later with an average prognosis error of 15 points. In addition, 3-risk classes were discerned with an accuracy of area under the curve = 0.74 (95% confidence interval 0.63-0.85). The RPI-S also distinguished persons with potentially modifiable prognostic indicators from 4 flag domains and stratified allocation to biopsychosocial treatments accordingly. Conclusion: The screening tools, developed in compliance with the PROGRESS and TRIPOD statements, revealed good validation and prognostic strength. These tools improve on existing screening tools because of their utility for secondary preventions, incorporation of exercise effect modifiers, exact pain estimations, and personalized allocation to multimodal treatments. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 351 KW - Back pain prognosis KW - Back pain diagnosis KW - Pain screening KW - PROGRESS/TRIPOD KW - Prediction of disability/intensity KW - Yellow flags KW - Exercise Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-403424 ER - TY - JOUR A1 - Wippert, Pia-Maria A1 - Puschmann, Anne-Katrin A1 - Drießlein, David A1 - Arampatzis, Adamantios A1 - Banzer, Winfried A1 - Beck, Heidrun A1 - Schiltenwolf, Marcus A1 - Schmidt, Hendrik A1 - Schneider, Christian A1 - Mayer, Frank T1 - Development of a risk stratification and prevention index for stratified care in chronic low back pain. Focus: yellow flags (MiSpEx network) JF - Pain reports N2 - Introduction: Chronic low back pain (LBP) is a major cause of disability; early diagnosis and stratification of care remain challenges. Objectives: This article describes the development of a screening tool for the 1-year prognosis of patients with high chronic LBP risk (risk stratification index) and for treatment allocation according to treatment-modifiable yellow flag indicators (risk prevention indices, RPI-S). Methods: Screening tools were derived from a multicentre longitudinal study (n = 1071, age >18, intermittent LBP). The greatest prognostic predictors of 4 flag domains ("pain," "distress," "social-environment," "medical care-environment") were determined using least absolute shrinkage and selection operator regression analysis. Internal validity and prognosis error were evaluated after 1-year follow-up. Receiver operating characteristic curves for discrimination (area under the curve) and cutoff values were determined. Results: The risk stratification index identified persons with increased risk of chronic LBP and accurately estimated expected pain intensity and disability on the Pain Grade Questionnaire (0-100 points) up to 1 year later with an average prognosis error of 15 points. In addition, 3-risk classes were discerned with an accuracy of area under the curve = 0.74 (95% confidence interval 0.63-0.85). The RPI-S also distinguished persons with potentially modifiable prognostic indicators from 4 flag domains and stratified allocation to biopsychosocial treatments accordingly. Conclusion: The screening tools, developed in compliance with the PROGRESS and TRIPOD statements, revealed good validation and prognostic strength. These tools improve on existing screening tools because of their utility for secondary preventions, incorporation of exercise effect modifiers, exact pain estimations, and personalized allocation to multimodal treatments. KW - Back pain prognosis KW - Back pain diagnosis KW - Pain screening KW - PROGRESS/TRIPOD KW - Prediction of disability/intensity KW - Yellow flags KW - Exercise Y1 - 2017 U6 - https://doi.org/10.1097/PR9.0000000000000623 VL - 9 SP - 1 EP - 11 PB - Wolters Kluwer Health CY - Riverwoods, IL ER - TY - JOUR A1 - Wippert, Pia-Maria A1 - Puschmann, Anne-Katrin A1 - Arampatzis, Adamantios A1 - Schiltenwolf, Marcus A1 - Mayer, Frank T1 - Diagnosis of psychosocial risk factors in prevention of low back pain in athletes (MiSpEx) JF - BMJ Open Sport & Exercise Medicine N2 - Background Low back pain (LBP) is a common pain syndrome in athletes, responsible for 28% of missed training days/year. Psychosocial factors contribute to chronic pain development. This study aims to investigate the transferability of psychosocial screening tools developed in the general population to athletes and to define athlete-specific thresholds. Methods Data from a prospective multicentre study on LBP were collected at baseline and 1-year follow-up (n=52 athletes, n=289 recreational athletes and n=246 non-athletes). Pain was assessed using the Chronic Pain Grade questionnaire. The psychosocial Risk Stratification Index (RSI) was used to obtain prognostic information regarding the risk of chronic LBP (CLBP). Individual psychosocial risk profile was gained with the Risk Prevention Index – Social (RPI-S). Differences between groups were calculated using general linear models and planned contrasts. Discrimination thresholds for athletes were defined with receiver operating characteristics (ROC) curves. Results Athletes and recreational athletes showed significantly lower psychosocial risk profiles and prognostic risk for CLBP than non-athletes. ROC curves suggested discrimination thresholds for athletes were different compared with non-athletes. Both screenings demonstrated very good sensitivity (RSI=100%; RPI-S: 75%–100%) and specificity (RSI: 76%–93%; RPI-S: 71%–93%). RSI revealed two risk classes for pain intensity (area under the curve (AUC) 0.92(95% CI 0.85 to 1.0)) and pain disability (AUC 0.88(95% CI 0.71 to 1.0)). Conclusions Both screening tools can be used for athletes. Athlete-specific thresholds will improve physicians’ decision making and allow stratified treatment and prevention. Y1 - 2017 U6 - https://doi.org/10.1136/bmjsem-2017-000295 SN - 2055-7647 VL - 3 IS - 1 ER - TY - GEN A1 - Wahmkow, Gunnar A1 - Cassel, Michael A1 - Mayer, Frank A1 - Baur, Heiner T1 - Effects of different medial arch support heights on rearfoot kinematics N2 - Background Foot orthoses are usually assumed to be effective by optimizing mechanically dynamic rearfoot configuration. However, the effect from a foot orthosis on kinematics that has been demonstrated scientifically has only been marginal. The aim of this study was to examine the effect of different heights in medial arch-supported foot orthoses on rear foot motion during gait. Methods Nineteen asymptomatic runners (36±11years, 180±5cm, 79±10kg; 41±22km/week) participated in the study. Trials were recorded at 3.1 mph (5 km/h) on a treadmill. Athletes walked barefoot and with 4 different not customized medial arch-supported foot orthoses of various arch heights (N:0 mm, M:30 mm, H:35 mm, E:40mm). Six infrared cameras and the `Oxford Foot Model´ were used to capture motion. The average stride in each condition was calculated from 50 gait cycles per condition. Eversion excursion and internal tibia rotation were analyzed. Descriptive statistics included calculating the mean ± SD and 95% CIs. Group differences by condition were analyzed by one factor (foot orthoses) repeated measures ANOVA (α = 0.05). Results Eversion excursion revealed the lowest values for N and highest for H (B:4.6°±2.2°; 95% CI [3.1;6.2]/N:4.0°±1.7°; [2.9;5.2]/M:5.2°±2.6°; [3.6;6.8]/H:6.2°±3.3°; [4.0;8.5]/E:5.1°±3.5°; [2.8;7.5]) (p>0.05). Range of internal tibia rotation was lowest with orthosis H and highest with E (B:13.3°±3.2°; 95% CI [11.0;15.6]/N:14.5°±7.2°; [9.2;19.6]/M:13.8°±5.0°; [10.8;16.8]/H:12.3°±4.3°; [9.0;15.6]/E:14.9°±5.0°; [11.5;18.3]) (p>0.05). Differences between conditions were small and the intrasubject variation high. Conclusion Our results indicate that different arch support heights have no systematic effect on eversion excursion or the range of internal tibia rotation and therefore might not exert a crucial influence on rear foot alignment during gait. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 348 Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-402934 ER - TY - JOUR A1 - Wahmkow, Gunnar A1 - Cassel, Michael A1 - Mayer, Frank A1 - Baur, Heiner T1 - Effects of different medial arch support heights on rearfoot kinematics JF - PLoS one N2 - Background Foot orthoses are usually assumed to be effective by optimizing mechanically dynamic rearfoot configuration. However, the effect from a foot orthosis on kinematics that has been demonstrated scientifically has only been marginal. The aim of this study was to examine the effect of different heights in medial arch-supported foot orthoses on rear foot motion during gait. Methods Nineteen asymptomatic runners (36±11years, 180±5cm, 79±10kg; 41±22km/week) participated in the study. Trials were recorded at 3.1 mph (5 km/h) on a treadmill. Athletes walked barefoot and with 4 different not customized medial arch-supported foot orthoses of various arch heights (N:0 mm, M:30 mm, H:35 mm, E:40mm). Six infrared cameras and the `Oxford Foot Model´ were used to capture motion. The average stride in each condition was calculated from 50 gait cycles per condition. Eversion excursion and internal tibia rotation were analyzed. Descriptive statistics included calculating the mean ± SD and 95% CIs. Group differences by condition were analyzed by one factor (foot orthoses) repeated measures ANOVA (α = 0.05). Results Eversion excursion revealed the lowest values for N and highest for H (B:4.6°±2.2°; 95% CI [3.1;6.2]/N:4.0°±1.7°; [2.9;5.2]/M:5.2°±2.6°; [3.6;6.8]/H:6.2°±3.3°; [4.0;8.5]/E:5.1°±3.5°; [2.8;7.5]) (p>0.05). Range of internal tibia rotation was lowest with orthosis H and highest with E (B:13.3°±3.2°; 95% CI [11.0;15.6]/N:14.5°±7.2°; [9.2;19.6]/M:13.8°±5.0°; [10.8;16.8]/H:12.3°±4.3°; [9.0;15.6]/E:14.9°±5.0°; [11.5;18.3]) (p>0.05). Differences between conditions were small and the intrasubject variation high. Conclusion Our results indicate that different arch support heights have no systematic effect on eversion excursion or the range of internal tibia rotation and therefore might not exert a crucial influence on rear foot alignment during gait. Y1 - 2017 U6 - https://doi.org/10.1371/journal.pone.0172334 SN - 1932-6203 VL - 12 IS - 3 PB - PLoS CY - Lawrence, Kan. ER - TY - JOUR A1 - Risch, Lucie A1 - Wochatz, Monique A1 - Messerschmidt, Janin A1 - Engel, Tilman A1 - Mayer, Frank A1 - Cassel, Michael T1 - Reliability of evaluating achilles tendon vascularization assessed with doppler ultrasound advanced dynamic flow JF - Journal of ultrasound in medicine N2 - The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems. Methods-Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen kappa and Fleiss kappa coefficients (absolute), Kendall tau b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]). Results-Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels). Conclusions-The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended. KW - advanced dynamic flow KW - intratendinous blood flow KW - musculoskeletal KW - reliability KW - ultrasound Y1 - 2017 U6 - https://doi.org/10.1002/jum.14414 SN - 0278-4297 SN - 1550-9613 VL - 37 IS - 3 SP - 737 EP - 744 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Risch, Lucie A1 - Cassel, Michael A1 - Mayer, Frank T1 - Acute effect of running exercise on physiological Achilles tendon blood flow JF - Scandinavian journal of medicine & science in sports N2 - Sonographically detectable intratendinous blood flow (IBF) is found in 50%-88% of Achilles tendinopathy patients as well as in up to 35% of asymptomatic Achilles tendons (AT). Although IBF is frequently associated with tendon pathology, it may also represent a physiological regulation, for example, due to increased blood flow in response to exercise. Therefore, this study aimed to investigate the acute effects of a standardized running exercise protocol on IBF assessed with Doppler ultrasound (DU) Advanced dynamic flow in healthy ATs. 10 recreationally active adults (5 f, 5m; 29 +/- 3years, 1.72 +/- 0.12m, 68 +/- 16kg, physical activity 206 +/- 145minute/wk) with no history of AT pain and inconspicious tendon structure performed 3 treadmill running tasks on separate days (M1-3) with DU examinations directly before and 5, 30, 60, and 120minutes after exercise. At M1, an incremental exercise test was used to determine the individual anaerobic threshold (IAT). At M2 and M3, participants performed 30-minute submaximal constant load tests (CL1/CL2) with an intensity 5% below IAT. IBF in each tendon was quantified by counting the number of vessels. IBF increased in five ATs from no vessels at baseline to one to four vessels solely detectable 5minutes after CL1 or CL2. One AT had persisting IBF (three vessels) throughout all examinations. Fourteen ATs revealed no IBF at all. Prolonged running led to a physiological, temporary appearance of IBF in 25% of asymptomatic ATs. To avoid exercise-induced IBF in clinical practice, DU examinations should be performed after 30minutes of rest. KW - advanced dynamic flow KW - doppler ultrasound KW - hyperemia KW - neovascularization KW - sonography Y1 - 2017 U6 - https://doi.org/10.1111/sms.12874 SN - 0905-7188 SN - 1600-0838 VL - 28 IS - 1 SP - 138 EP - 143 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Rector, Michael V. A1 - Intziegianni, Konstantina A1 - Müller, Steffen A1 - Mayer, Frank A1 - Cassel, Michael T1 - Reproducibility of an ankle joint rotation correction method for assessment of Achilles tendon elongation JF - Isokinetics and exercise science : official journal of the European Isokinetic Society N2 - BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly. KW - Ultrasonography KW - Achilles tendon KW - reproducibility KW - isokinetic KW - ankle joint rotation Y1 - 2017 U6 - https://doi.org/10.3233/IES-160644 SN - 0959-3020 SN - 1878-5913 VL - 25 IS - 1 SP - 47 EP - 52 PB - IOS Press CY - Amsterdam ER -