TY - JOUR A1 - Risch, Lucie A1 - Cassel, Michael A1 - Mayer, Frank T1 - Acute effect of running exercise on physiological Achilles tendon blood flow JF - Scandinavian journal of medicine & science in sports N2 - Sonographically detectable intratendinous blood flow (IBF) is found in 50%-88% of Achilles tendinopathy patients as well as in up to 35% of asymptomatic Achilles tendons (AT). Although IBF is frequently associated with tendon pathology, it may also represent a physiological regulation, for example, due to increased blood flow in response to exercise. Therefore, this study aimed to investigate the acute effects of a standardized running exercise protocol on IBF assessed with Doppler ultrasound (DU) Advanced dynamic flow in healthy ATs. 10 recreationally active adults (5 f, 5m; 29 +/- 3years, 1.72 +/- 0.12m, 68 +/- 16kg, physical activity 206 +/- 145minute/wk) with no history of AT pain and inconspicious tendon structure performed 3 treadmill running tasks on separate days (M1-3) with DU examinations directly before and 5, 30, 60, and 120minutes after exercise. At M1, an incremental exercise test was used to determine the individual anaerobic threshold (IAT). At M2 and M3, participants performed 30-minute submaximal constant load tests (CL1/CL2) with an intensity 5% below IAT. IBF in each tendon was quantified by counting the number of vessels. IBF increased in five ATs from no vessels at baseline to one to four vessels solely detectable 5minutes after CL1 or CL2. One AT had persisting IBF (three vessels) throughout all examinations. Fourteen ATs revealed no IBF at all. Prolonged running led to a physiological, temporary appearance of IBF in 25% of asymptomatic ATs. To avoid exercise-induced IBF in clinical practice, DU examinations should be performed after 30minutes of rest. KW - advanced dynamic flow KW - doppler ultrasound KW - hyperemia KW - neovascularization KW - sonography Y1 - 2017 U6 - https://doi.org/10.1111/sms.12874 SN - 0905-7188 SN - 1600-0838 VL - 28 IS - 1 SP - 138 EP - 143 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Risch, Lucie A1 - Mueller, Steffen A1 - Engel, Tilman A1 - Mayer, Frank T1 - Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes: A Longitudinal Study JF - Frontiers in physiology N2 - Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 +/- 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean SD) and statistical testing for group differences was performed (cy = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 +/- 0.7 mm/5.6 +/- 0.7 mm) nor in controls (4.8 +/- 0.4 mm/4.9 +/- 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (Ml: 3.5 +/- 0.5 mm, M2: 3.8 +/- 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p <= 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports. KW - Achilles and patellar tendon KW - training adaptation KW - sonography KW - young athletes KW - non-athletes Y1 - 2017 U6 - https://doi.org/10.3389/fphys.2017.00795 SN - 1664-042X VL - 8 SP - 599 EP - 611 PB - Frontiers Research Foundation CY - Lausanne ER - TY - GEN A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Risch, Lucie A1 - Müller, Steffen A1 - Engel, Tilman A1 - Mayer, Frank T1 - Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes BT - A Longitudinal Study N2 - Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 355 KW - Achilles and patellar tendon KW - non-athletes KW - sonography KW - training adaptation KW - young athletes Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-403823 ER - TY - JOUR A1 - Cassel, Michael A1 - Intziegianni, Konstantina A1 - Risch, Lucie A1 - Müller, Steffen A1 - Engel, Tilman A1 - Mayer, Frank T1 - Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes BT - A Longitudinal Study JF - Frontiers in physiology N2 - Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports. KW - Achilles and patellar tendon KW - training adaptation KW - sonography KW - young athletes KW - non-athletes Y1 - 2017 U6 - https://doi.org/10.3389/fphys.2017.00795 SN - 1664-042X VL - 8 SP - 1 EP - 8 PB - Frontiers CY - Lausanne ER - TY - GEN A1 - Bisi-Balogun, Adebisi A1 - Cassel, Michael A1 - Mayer, Frank T1 - Reliability of various measurement stations for determining plantar fascia thickness and echogenicity N2 - This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of 0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. T3 - Zweitveröffentlichungen der Universität Potsdam : Humanwissenschaftliche Reihe - 339 KW - plantar fascia KW - reliability KW - sonography KW - musculoskeletal Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-400615 ER -