TY - JOUR A1 - Villatoro, José Andrés A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Weber, Marcus A1 - Riedel, Jens A1 - Löhmannsröben, Hans-Gerd T1 - IR-MALDI ion mobility spectrometry: physical source characterization and application as HPLC detector JF - International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry N2 - Infrared matrix-assisted laser dispersion and ionization (IR-MALDI) in combination with ion mobility (IM) spectrometry enables the direct analysis of biomolecules in aqueous solution. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse, which disperses the liquid as vapor, nano-and micro-droplets. The ionization process is characterized initially by a broad spatial distribution of the ions, which is a result of complex fluid dynamics and desolvation kinetics. These processes have a profound effect on the shape and width of the peaks in the IM spectra. In this work, the transport of ions by the phase explosion-induced shockwave could be studied independently from the transport by the electric field. The shockwave-induced mean velocities of the ions at different time scales were determined through IM spectrometry and shadowgraphy. The results show a deceleration of the ions from 118 m.s(-1) at a distance of 400 mu m from the liquid surface to 7.1 m.s(-1) at a distance of 10 mm, which is caused by a pile-up effect. Furthermore, the desolvation kinetics were investigated and a first-order desolvation constant of 325 +/- 50 s(-1) was obtained. In the second part, the IR-MALDI-IM spectrometer is used as an HPLC detector for the two-dimensional separation of a pesticide mixture. KW - Ion mobility spectrometry KW - IR-MALDI KW - Shadowgraphy KW - Laser KW - Imaging KW - HPLC Y1 - 2016 U6 - https://doi.org/10.1007/s12127-016-0208-1 SN - 1435-6163 SN - 1865-4584 VL - 19 SP - 197 EP - 207 PB - Springer CY - Heidelberg ER - TY - THES A1 - Zühlke, Martin T1 - Elektrosprayionisation Ionenmobilitätsspektrometrie T1 - Electrospray ionization Ion mobility spectrometry BT - Entwicklung, Charakterisierung und Anwendung zur HPLC-Detektion und zum Reaktionsmonitoring BT - development, characterization and application for HPLC detection and reaction monitoring N2 - Die Elektrosprayionisation (ESI) ist eine der weitverbreitetsten Ionisationstechniken für flüssige Pro-ben in der Massen- und Ionenmobilitäts(IM)-Spektrometrie. Aufgrund ihrer schonenden Ionisierung wird ESI vorwiegend für empfindliche, komplexe Moleküle in der Biologie und Medizin eingesetzt. Überdies ist sie allerdings für ein sehr breites Spektrum an Substanzklassen anwendbar. Die IM-Spektrometrie wurde ursprünglich zur Detektion gasförmiger Proben entwickelt, die hauptsächlich durch radioaktive Quellen ionisiert werden. Sie ist die einzige analytische Methode, bei der Isomere in Echtzeit getrennt und über ihre charakteristische IM direkt identifiziert werden können. ESI wurde in den 90ger Jahren durch die Hill Gruppe in die IM-Spektrometrie eingeführt. Die Kombination wird bisher jedoch nur von wenigen Gruppen verwendet und hat deshalb noch ein hohes Entwick-lungspotential. Ein vielversprechendes Anwendungsfeld ist der Einsatz in der Hochleistungs-flüssigkeitschromatographie (HPLC) zur mehrdimensionalen Trennung. Heutzutage ist die HPLC die Standardmethode zur Trennung komplexer Proben in der Routineanalytik. HPLC-Trennungsgänge sind jedoch häufig langwierig und der Einsatz verschiedener Laufmittel, hoher Flussraten, von Puffern, sowie Laufmittelgradienten stellt hohe Anforderungen an die Detektoren. Die ESI-IM-Spektrometrie wurde in einigen Studien bereits als HPLC-Detektor eingesetzt, war dort bisher jedoch auf Flussratensplitting oder geringe Flussraten des Laufmittels beschränkt. In dieser kumulativen Doktorarbeit konnte daher erstmals ein ESI IM-Spektrometer als HPLC-Detektor für den Flussratenbereich von 200-1500 μl/min entwickelt werden. Anhand von fünf Publi-kationen wurden (1) über eine umfassende Charakterisierung die Eignung des Spektrometers als HPLC-Detektor festgestellt, (2) ausgewählte komplexe Trenngänge präsentiert und (3) die Anwen-dung zum Reaktionsmonitoring und (4, 5) mögliche Weiterentwicklungen gezeigt. Erfolgreich konnten mit dem selbst-entwickelten ESI IM-Spektrometer typische HPLC-Bedingungen wie Wassergehalte im Laufmittel von bis zu 90%, Pufferkonzentrationen von bis zu 10 mM, sowie Nachweisgrenzen von bis zu 50 nM erreicht werden. Weiterhin wurde anhand der komplexen Trennungsgänge (24 Pestizide/18 Aminosäuren) gezeigt, dass die HPLC und die IM-Spektrometrie eine hohe Orthogonalität besitzen. Eine effektive Peakkapazität von 240 wurde so realisiert. Auf der HPLC-Säule koeluierende Substanzen konnten über die Driftzeit getrennt und über ihre IM identifi-ziert werden, sodass die Gesamttrennzeiten erheblich minimiert werden konnten. Die Anwend-barkeit des ESI IM-Spektrometers zur Überwachung chemischer Synthesen wurde anhand einer dreistufigen Reaktion demonstriert. Es konnten die wichtigsten Edukte, Zwischenprodukte und Produkte aller Stufen identifiziert werden. Eine quantitative Auswertung war sowohl über eine kurze HPLC-Vortrennung als auch durch die Entwicklung eines eigenen Kalibrierverfahrens, welches die Ladungskonkurrenz bei ESI berücksichtigt, ohne HPLC möglich. Im zweiten Teil der Arbeit werden zwei Weiterentwicklungen des Spektrometers präsentiert. Eine Möglichkeit ist die Reduzierung des Drucks in den intermediären Bereich (300 - 1000 mbar) mit dem Ziel der Verringerung der benötigten Spannungen. Mithilfe von Streulichtbildern und Strom-Spannungs-Kurven wurden für geringe Drücke eine verminderte Freisetzung der Analyt-Ionen aus den Tropfen festgestellt. Die Verluste konnten jedoch über höhere elektrische Feldstärken ausgeglichen werden, sodass gleiche Nachweisgrenzen bei 500 mbar und bei 1 bar erreicht wurden. Die zweite Weiterentwicklung ist ein neuartiges Ionentors mit Pulsschaltung, welches eine Verdopplung der Auflösung auf bis zu R > 100 bei gleicher Sensitivität ermöglichte. Eine denkbare Anwendung im Bereich der Peptidanalytik wurde mit beachtlichen Auflösungen der Peptide von R = 90 gezeigt. N2 - Electrospray ionization (ESI) is one of the most widespread ionization techniques for liquid samples in mass and ion mobility (IM) spectrometry. Due to its gentle ionization, ESI is often used for sensitive, complex molecules in biology and medicine. However, it is also applicable to a wide range of substance classes. IM spectrometry was originally developed for the detection of gaseous samples, which are mainly ionized by radioactive sources. It is the only analytical method in which isomers can be separated in real time and directly identified by their characteristic IM. ESI was introduced to IM spectrometry by the Hill Group in the 90s. So far, the combination was only used by a limited number of groups and therefore there is still a large development potential. A highly promising field of application is highperformance liquid chromatography (HPLC) for multidimensional separations. At present, HPLC is the standard method for the separation of complex samples in routine analysis. However, HPLC separations are often time-consuming and the use of different solvents, high flow rates, buffers, as well as solvent gradients impose high demands on the detectors. ESI IM spectrometry was already used as an HPLC detector in a number of studies. However, these studies were restricted to splitting or low flow rates of the mobile phase. In this cumulative thesis, an ESI IM spectrometer was developed as an HPLC detector for the flow rate range of 200-1500 μl/min for the first time. Based on five publications, (1) the suitability of the spectrometer as an HPLC detector was comprehensively characterized, (2) selected complex separations are presented, and (3) the application to the reaction monitoring as well as (4, 5) possible further developments are shown. With the in-house developed ESI IM spectrometer, typical HPLC conditions such as water contents in the mobile phase of up to 90%, buffer concentrations of up to 10 mM, as well as detection limits of up to 50 nM, were achieved successfully. Furthermore, on the basis of a complex separation (24 pesticides/18 amino acids), it could be demonstrated that HPLC and IM spectrometry possess a high degree of orthogonality. An effective peak capacity of 240 was thus realized. Substances coeulating on the HPLC column could be separated in the drift time and were identified by their IM. Thus, the overall separation times could be significantly reduced. The applicability of the ESI IM spectrometer for the monitoring of chemical syntheses was demonstrated for a three-stage reaction. The main starting materials, intermediates and products of all stages could be identified. A quantitative evaluation was possible both by means of a short HPLC pre-separation as well as by a newly developed calibration procedure, which takes charge competition during ESI into account, without HPLC. In the second part of the thesis, two further developments of the spectrometer are presented. One possibility is a reduction of the pressure to the intermediate range (300 - 1000 mbar) with the aim of reducing the required voltages. With the help of scattered light images and current-voltage curves, a reduced release of analyte ions from the droplets was determined at low pressures. However, these losses could be compensated for by higher electric field strengths. Therefore, the same detection limits were achieved at 500 mbar and at 1 bar. The second development is a novel ion gate with pulse switching, which allows a doubling of the resolution up to R > 100 with equal sensitivity. A possible application in the field of peptide analysis was demonstrated, achieving a considerable resolutions of R = 90 for the peptides. KW - HPLC KW - HPLC KW - Ionenmobilitätsspektrometrie KW - Elektrosprayionisation KW - ion mobility spectrometry KW - electrospray ionization (ESI) Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-407452 ER - TY - JOUR A1 - Zühlke, Martin A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd A1 - Zenichowski, Karl A1 - Diener, Marc A1 - Linscheid, Michael W. T1 - An electrospray ionization-ion mobility spectrometer as detector for high-performance liquid chromatography JF - European journal of mass spectrometry N2 - The application of electrospray ionization (ESI) ion mobility (IM) spectrometry on the detection end of a high-performance liquid chromatograph has been a subject of study for some time. So far, this method has been limited to low flow rates or has required splitting of the liquid flow. This work presents a novel concept of an ESI source facilitating the stable operation of the spectrometer at flow rates between 10 mu L min(-1) and 1500 mu L min(-1) without flow splitting, advancing the T-cylinder design developed by Kurnin and co-workers. Flow rates eight times faster than previously reported were achieved because of a more efficient dispersion of the liquid at increased electrospray voltages combined with nebulization by a sheath gas. Imaging revealed the spray operation to be in a rotationally symmetric multijet-mode. The novel ESI-IM spectrometer tolerates high water contents (<= 90%) and electrolyte concentrations up to 10 mM, meeting another condition required of high-performance liquid chromatography (HPLC) detectors. Limits of detection of 50 nM for promazine in the positive mode and 1 mu M for 1,3-dinitrobenzene in the negative mode were established. Three mixtures of reduced complexity (five surfactants, four neuroleptics, and two isomers) were separated in the millisecond regime in stand-alone operation of the spectrometer. Separations of two more complex mixtures (five neuroleptics and 13 pesticides) demonstrate the application of the spectrometer as an HPLC detector. The examples illustrate the advantages of the spectrometer over the established diode array detector, in terms of additional IM separation of substances not fully separated in the retention time domain as well as identification of substances based on their characteristic IMs. KW - ESI KW - IMS KW - HPLC KW - spray imaging KW - neuroleptics KW - pesticides KW - surfactants Y1 - 2015 U6 - https://doi.org/10.1255/ejms.1367 SN - 1469-0667 SN - 1751-6838 VL - 21 IS - 3 SP - 391 EP - 402 PB - WeltTrends CY - Sussex ER - TY - JOUR A1 - Zühlke, Martin A1 - Sass, Stephan A1 - Riebe, Daniel A1 - Beitz, Toralf A1 - Löhmannsröben, Hans-Gerd T1 - Real-Time Reaction Monitoring of an Organic Multistep Reaction by Electrospray Ionization-Ion Mobility Spectrometry JF - ChemPlusChem N2 - The capability of electrospray ionization (ESI)-ion mobility (IM) spectrometry for reaction monitoring is assessed both as a stand-alone real-time technique and in combination with HPLC. A three-step chemical reaction, consisting of a Williamson ether synthesis followed by a hydrogenation and an N-alkylation step, is chosen for demonstration. Intermediates and products are determined with a drift time to mass-per-charge correlation. Addition of an HPLC column to the setup increases the separation power and allows the determination of further species. Monitoring of the intensities of the various species over the reaction time allows the detection of the end of reaction, determination of the rate-limiting step, observation of the system response in discontinuous processes, and optimization of the mass ratios of the starting materials. However, charge competition in ESI influences the quantitative detection of substances in the reaction mixture. Therefore, two different methods are investigated, which allow the quantification and investigation of reaction kinetics. The first method is based on the pre-separation of the compounds on an HPLC column and their subsequent individual detection in the ESI-IM spectrometer. The second method involves an extended calibration procedure, which considers charge competition effects and facilitates nearly real-time quantification. KW - electrospray ionization KW - HPLC KW - ion mobility spectrometry KW - reaction mechanisms KW - reaction monitoring Y1 - 2017 U6 - https://doi.org/10.1002/cplu.201700296 SN - 2192-6506 VL - 82 SP - 1266 EP - 1273 PB - Wiley-VCH CY - Weinheim ER -