TY - JOUR A1 - Intziegianni, Konstantina A1 - Cassel, Michael A1 - König, Niklas A1 - Müller, Steffen A1 - Fröhlich, Katja A1 - Mayer, Frank T1 - Ultrasonography for the assessment of the structural properties of the Achilles tendon in asymptomatic individuals: An intra-rater reproducibility study JF - Isokinetics and exercise science : official journal of the European Isokinetic Society N2 - BACKGROUND: Reproducible measurements of tendon structural properties are a prerequisite for accurate diagnosis of tendon disorders and for determination of their mechanical properties. Despite the widely used application of Ultrasonography (US) in musculoskeletal assessment, its operator dependency and lack of standardization influences the consistency of the measurement. OBJECTIVE: To evaluate the intra-rater reproducibility of a standardized US method assessing the structural properties of the Achilles tendon (AT). METHODS: Sixteen asymptomatic participants were positioned prone on an isokinetic dynamometer with the knee extended and ankle at 90. flexion. US was used to assess AT-length, cross-sectional area (CSA), and AT-elongation during isometric plantarflexion contraction. The intra-rater reproducibility was assessed by ICC (2.1), Test-Retest Variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]), and Standard-Error of Measurement (SEM). RESULTS: Measurements of AT-length demonstrated an ICC of 0.93, TRV of 4.5 +/- 3.9%, Bias +/- LoA of -2.8 +/- 25.0 mm and SEM of 6.6 mm. AT-CSA showed an ICC of 0.79, TRV of 8.7 +/- 9.6%, Bias +/- LoA of 1.7 +/- 19.4 mm(2) and SEM of 5.3 mm(2). AT-elongation revealed an ICC of 0.92, TRV of 12.9 +/- 8.9%, Bias +/- LoA of 0.3 +/- 5.7 mm and SEM of 1.5 mm. CONCLUSIONS: The presented methodology allows a reproducible assessment of Achilles tendon structural properties when performed by a single rater. KW - Ultrasonography KW - Achilles tendon KW - reproducibility KW - isokinetic Y1 - 2015 U6 - https://doi.org/10.3233/IES-150586 SN - 0959-3020 SN - 1878-5913 VL - 23 IS - 4 SP - 263 EP - 270 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Rector, Michael V. A1 - Intziegianni, Konstantina A1 - Müller, Steffen A1 - Mayer, Frank A1 - Cassel, Michael T1 - Reproducibility of an ankle joint rotation correction method for assessment of Achilles tendon elongation JF - Isokinetics and exercise science : official journal of the European Isokinetic Society N2 - BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias +/- LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 +/- 19%. Bias +/- LoA were determined to be 0.0 +/- 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly. KW - Ultrasonography KW - Achilles tendon KW - reproducibility KW - isokinetic KW - ankle joint rotation Y1 - 2017 U6 - https://doi.org/10.3233/IES-160644 SN - 0959-3020 SN - 1878-5913 VL - 25 IS - 1 SP - 47 EP - 52 PB - IOS Press CY - Amsterdam ER -