@article{HannemannKruegerDahm2014, author = {Hannemann, Katrin and Kr{\"u}ger, Frank and Dahm, Torsten}, title = {Measuring of clock drift rates and static time offsets of ocean bottom stations by means of ambient noise}, series = {Geophysical journal international}, volume = {196}, journal = {Geophysical journal international}, number = {2}, publisher = {Oxford Univ. Press}, address = {Oxford}, issn = {0956-540X}, doi = {10.1093/gji/ggt434}, pages = {1034 -- 1042}, year = {2014}, abstract = {Marine seismology usually relies on temporary deployments of stand alone seismic ocean bottom stations (OBS), which are initialized and synchronized on ship before deployment and re-synchronized and stopped on ship after recovery several months later. In between, the recorder clocks may drift and float at unknown rates. If the clock drifts are large or not linear and cannot be corrected for, seismological applications will be limited to methods not requiring precise common timing. Therefore, for example, array seismological methods, which need very accurate timing between individual stations, would not be applicable for such deployments. We use an OBS test-array of 12 stations and 75 km aperture, deployed for 10 months in the deep sea (4.5-5.5 km) of the mid-eastern Atlantic. The experiment was designed to analyse the potential of broad-band array seismology at the seafloor. After recovery, we identified some stations which either show unusual large clock drifts and/or static time offsets by having a large difference between the internal clock and the GPS-signal (skew). We test the approach of ambient noise cross-correlation to synchronize clocks of a deep water OBS array with km-scale interstation distances. We show that small drift rates and static time offsets can be resolved on vertical components with a standard technique. Larger clock drifts (several seconds per day) can only be accurately recovered if time windows of one input trace are shifted according to the expected drift between a station pair before the cross-correlation. We validate that the drifts extracted from the seismometer data are linear to first order. The same is valid for most of the hydrophones. Moreover, we were able to determine the clock drift at a station where no skew could be measured. Furthermore, we find that instable apparent drift rates at some hydrophones, which are uncorrelated to the seismometer drift recorded at the same digitizer, indicate a malfunction of the hydrophone.}, language = {en} } @article{GrigoliCescaAmorosoetal.2014, author = {Grigoli, Francesco and Cesca, Simone and Amoroso, Ortensia and Emolo, Antonio and Zollo, Aldo and Dahm, Torsten}, title = {Automated seismic event location by waveform coherence analysis}, series = {Geophysical journal international}, volume = {196}, journal = {Geophysical journal international}, number = {3}, publisher = {Oxford Univ. Press}, address = {Oxford}, issn = {0956-540X}, doi = {10.1093/gji/ggt477}, pages = {1742 -- 1753}, year = {2014}, abstract = {Automated location of seismic events is a very important task in microseismic monitoring operations as well for local and regional seismic monitoring. Since microseismic records are generally characterized by low signal-to-noise ratio, automated location methods are requested to be noise robust and sufficiently accurate. Most of the standard automated location routines are based on the automated picking, identification and association of the first arrivals of P and S waves and on the minimization of the residuals between theoretical and observed arrival times of the considered seismic phases. Although current methods can accurately pick P onsets, the automatic picking of the S onset is still problematic, especially when the P coda overlaps the S wave onset. In this paper, we propose a picking free earthquake location method based on the use of the short-term-average/long-term-average (STA/LTA) traces at different stations as observed data. For the P phases, we use the STA/LTA traces of the vertical energy function, whereas for the S phases, we use the STA/LTA traces of a second characteristic function, which is obtained using the principal component analysis technique. In order to locate the seismic event, we scan the space of possible hypocentral locations and origin times, and stack the STA/LTA traces along the theoretical arrival time surface for both P and S phases. Iterating this procedure on a 3-D grid, we retrieve a multidimensional matrix whose absolute maximum corresponds to the spatial coordinates of the seismic event. A pilot application was performed in the Campania-Lucania region (southern Italy) using a seismic network (Irpinia Seismic Network) with an aperture of about 150 km. We located 196 crustal earthquakes (depth < 20 km) with magnitude range 1.1 < M-L < 2.7. A subset of these locations were compared with accurate manual locations refined by using a double-difference technique. Our results indicate a good agreement with manual locations. Moreover, our method is noise robust and performs better than classical location methods based on the automatic picking of the P and S waves first arrivals.}, language = {en} }