@phdthesis{Schuetz2013, author = {Sch{\"u}tz, Felina}, title = {Surface heat flow and lithospheric thermal structure of the northwestern Arabian Plate}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-69622}, school = {Universit{\"a}t Potsdam}, year = {2013}, abstract = {The surface heat flow (qs) is paramount for modeling the thermal structure of the lithosphere. Changes in the qs over a distinct lithospheric unit are normally directly reflecting changes in the crustal composition and therewith the radiogenic heat budget (e.g., Rudnick et al., 1998; F{\"o}rster and F{\"o}rster, 2000; Mareschal and Jaupart, 2004; Perry et al., 2006; Hasterok and Chapman, 2011, and references therein) or, less usual, changes in the mantle heat flow (e.g., Pollack and Chapman, 1977). Knowledge of this physical property is therefore of great interest for both academic research and the energy industry. The present study focuses on the qs of central and southern Israel as part of the Sinai Microplate (SM). Having formed during Oligocene to Miocene rifting and break-up of the African and Arabian plates, the SM is characterized by a young and complex tectonic history. Resulting from the time thermal diffusion needs to pass through the lithosphere, on the order of several tens-of-millions of years (e.g., Fowler, 1990); qs-values of the area reflect conditions of pre-Oligocene times. The thermal structure of the lithosphere beneath the SM in general, and south-central Israel in particular, has remained poorly understood. To address this problem, the two parameters needed for the qs determination were investigated. Temperature measurements were made at ten pre-existing oil and water exploration wells, and the thermal conductivity of 240 drill core and outcrop samples was measured in the lab. The thermal conductivity is the sensitive parameter in this determination. Lab measurements were performed on both, dry and water-saturated samples, which is labor- and time-consuming. Another possibility is the measurement of thermal conductivity in dry state and the conversion to a saturated value by using mean model approaches. The availability of a voluminous and diverse dataset of thermal conductivity values in this study allowed (1) in connection with the temperature gradient to calculate new reliable qs values and to use them to model the thermal pattern of the crust in south-central Israel, prior to young tectonic events, and (2) in connection with comparable datasets, controlling the quality of different mean model approaches for indirect determination of bulk thermal conductivity (BTC) of rocks. The reliability of numerically derived BTC values appears to vary between different mean models, and is also strongly dependent upon sample lithology. Yet, correction algorithms may significantly reduce the mismatch between measured and calculated conductivity values based on the different mean models. Furthermore, the dataset allowed the derivation of lithotype-specific conversion equations to calculate the water-saturated BTC directly from data of dry-measured BTC and porosity (e.g., well log derived porosity) with no use of any mean model and thus provide a suitable tool for fast analysis of large datasets. The results of the study indicate that the qs in the study area is significantly higher than previously assumed. The new presented qs values range between 50 and 62 mW m⁻². A weak trend of decreasing heat flow can be identified from the east to the west (55-50 mW m⁻²), and an increase from the Dead Sea Basin to the south (55-62 mW m⁻²). The observed range can be explained by variation in the composition (heat production) of the upper crust, accompanied by more systematic spatial changes in its thickness. The new qs data then can be used, in conjunction with petrophysical data and information on the structure and composition of the lithosphere, to adjust a model of the pre-Oligocene thermal state of the crust in south-central Israel. The 2-D steady-state temperature model was calculated along an E-W traverse based on the DESIRE seismic profile (Mechie et al., 2009). The model comprises the entire lithosphere down to the lithosphere-asthenosphere boundary (LAB) involving the most recent knowledge of the lithosphere in pre-Oligocene time, i.e., prior to the onset of rifting and plume-related lithospheric thermal perturbations. The adjustment of modeled and measured qs allows conclusions about the pre-Oligocene LAB-depth. After the best fitting the most likely depth is 150 km which is consistent with estimations made in comparable regions of the Arabian Shield. It therefore comprises the first ever modelled pre-Oligocene LAB depth, and provides important clues on the thermal state of lithosphere before rifting. This, in turn, is vital for a better understanding of the (thermo)-dynamic processes associated with lithosphere extension and continental break-up.}, language = {en} } @phdthesis{Schintgen2016, author = {Schintgen, Tom Vincent}, title = {The geothermal potential of Luxembourg}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-87110}, school = {Universit{\"a}t Potsdam}, pages = {XXII, 313}, year = {2016}, abstract = {The aim of this work is the evaluation of the geothermal potential of Luxembourg. The approach consists in a joint interpretation of different types of information necessary for a first rather qualitative assessment of deep geothermal reservoirs in Luxembourg and the adjoining regions in the surrounding countries of Belgium, France and Germany. For the identification of geothermal reservoirs by exploration, geological, thermal, hydrogeological and structural data are necessary. Until recently, however, reliable information about the thermal field and the regional geology, and thus about potential geothermal reservoirs, was lacking. Before a proper evaluation of the geothermal potential can be performed, a comprehensive survey of the geology and an assessment of the thermal field are required. As a first step, the geology and basin structure of the Mesozoic Trier-Luxembourg Basin (TLB) is reviewed and updated using recently published information on the geology and structures as well as borehole data available in Luxembourg and the adjoining regions. A Bouguer map is used to get insight in the depth, morphology and structures in the Variscan basement buried beneath the Trier-Luxembourg Basin. The geological section of the old Cessange borehole is reinterpreted and provides, in combination with the available borehole data, consistent information for the production of isopach maps. The latter visualize the synsedimentary evolution of the Trier-Luxembourg Basin. Complementary, basin-wide cross sections illustrate the evolution and structure of the Trier-Luxembourg Basin. The knowledge gained does not support the old concept of the Weilerbach Mulde. The basin-wide cross sections, as well as the structural and sedimentological observations in the Trier-Luxembourg Basin suggest that the latter probably formed above a zone of weakness related to a buried Rotliegend graben. The inferred graben structure designated by SE-Luxembourg Graben (SELG) is located in direct southwestern continuation of the Wittlicher Rotliegend-Senke. The lack of deep boreholes and subsurface temperature prognosis at depth is circumnavigated by using thermal modelling for inferring the geothermal resource at depth. For this approach, profound structural, geological and petrophysical input data are required. Conceptual geological cross sections encompassing the entire crust are constructed and further simplified and extended to lithospheric scale for their utilization as thermal models. The 2-D steady state and conductive models are parameterized by means of measured petrophysical properties including thermal conductivity, radiogenic heat production and density. A surface heat flow of 75 ∓ 7 (2δ) mW m-2 for verification of the thermal models could be determined in the area. The models are further constrained by the geophysically-estimated depth of the lithosphere-asthenosphere boundary (LAB) defined by the 1300 °C isotherm. A LAB depth of 100 km, as seismically derived for the Ardennes, provides the best fit with the measured surface heat flow. The resulting mantle heat flow amounts to ∼40 mW m-2. Modelled temperatures are in the range of 120-125 °C at 5 km depth and of 600-650 °C at the crust/mantle discontinuity (Moho). Possible thermal consequences of the 10-20 Ma old Eifel plume, which apparently caused upwelling of the asthenospheric mantle to 50-60 km depth, were modelled in a steady-state thermal scenario resulting in a surface heat flow of at least 91 mW m-2 (for the plume top at 60 km) in the Eifel region. Available surface heat-flow values are significantly lower (65-80 mW m-2) and indicate that the plume-related heating has not yet entirely reached the surface. Once conceptual geological models are established and the thermal regime is assessed, the geothermal potential of Luxembourg and the surrounding areas is evaluated by additional consideration of the hydrogeology, the stress field and tectonically active regions. On the one hand, low-enthalpy hydrothermal reservoirs in Mesozoic reservoirs in the Trier-Luxembourg Embayment (TLE) are considered. On the other hand, petrothermal reservoirs in the Lower Devonian basement of the Ardennes and Eifel regions are considered for exploitation by Enhanced/Engineered Geothermal Systems (EGS). Among the Mesozoic aquifers, the Buntsandstein aquifer characterized by temperatures of up to 50 °C is a suitable hydrothermal reservoir that may be exploited by means of heat pumps or provide direct heat for various applications. The most promising area is the zone of the SE-Luxembourg Graben. The aquifer is warmest underneath the upper Alzette River valley and the limestone plateau in Lorraine, where the Buntsandstein aquifer lies below a thick Mesozoic cover. At the base of an inferred Rotliegend graben in the same area, temperatures of up to 75 °C are expected. However, geological and hydraulic conditions are uncertain. In the Lower Devonian basement, thick sandstone-/quartzite-rich formations with temperatures >90 °C are expected at depths >3.5 km and likely offer the possibility of direct heat use. The setting of the S{\"u}deifel (South Eifel) region, including the M{\"u}llerthal region near Echternach, as a tectonically active zone may offer the possibility of deep hydrothermal reservoirs in the fractured Lower Devonian basement. Based on the recent findings about the structure of the Trier-Luxembourg Basin, the new concept presents the M{\"u}llerthal-S{\"u}deifel Depression (MSD) as a Cenozoic structure that remains tectonically active and subsiding, and therefore is relevant for geothermal exploration. Beyond direct use of geothermal heat, the expected modest temperatures at 5 km depth (about 120 °C) and increased permeability by EGS in the quartzite-rich Lochkovian could prospectively enable combined geothermal heat production and power generation in Luxembourg and the western realm of the Eifel region.}, language = {en} }