@phdthesis{Federico2011, author = {Federico, Stefania}, title = {Synthetic peptides derived from decorin as building blocks for biomaterials based on supramolecular interactions}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus-59661}, school = {Universit{\"a}t Potsdam}, year = {2011}, abstract = {In this work, the development of a new molecular building block, based on synthetic peptides derived from decorin, is presented. These peptides represent a promising basis for the design of polymer-based biomaterials that mimic the ECM on a molecular level and exploit specific biological recognition for technical applications. Multiple sequence alignments of the internal repeats of decorin that formed the inner and outer surface of the arch-shaped protein were used to develop consensus sequences. These sequences contained conserved sequence motifs that are likely to be related to structural and functional features of the protein. Peptides representative for the consensus sequences were synthesized by microwave-assisted solid phase peptide synthesis and purified by RP-HPLC, with purities higher than 95 mol\%. After confirming the desired masses by MALDI-TOF-MS, the primary structure of each peptide was investigated by 1H and 2D NMR, from which a full assignment of the chemical shifts was obtained. The characterization of the peptides conformation in solution was performed by CD spectroscopy, which demonstrated that using TFE, the peptides from the outer surface of decorin show a high propensity to fold into helical structures as observed in the original protein. To the contrary, the peptides from the inner surface did not show propensity to form stable secondary structure. The investigation of the binding capability of the peptides to Collagen I was performed by surface plasmon resonance analyses, from which all but one of the peptides representing the inner surface of decorin showed binding affinity to collagen with values of dissociation constant between 2•10-7 M and 2.3•10-4 M. On the other hand, the peptides representative for the outer surface of decorin did not show any significant interaction to collagen. This information was then used to develop experimental demonstration for the binding capabilities of the peptides from the inner surface of decorin to collagen even when used in more complicated situations close to possible appications. With this purpose, the peptide (LRELHLNNN) which showed the highest binding affinity to collagen (2•10-7 M) was functionalized with an N-terminal triple bond in order to obtain a peptide dimer via copper(I)-catalyzed cycloaddition reaction with 4,4'-diazidostilbene-2,2'-disulfonic acid. Rheological measurements showed that the presence of the peptide dimer was able to enhance the elastic modulus (G') of a collagen gel from ~ 600 Pa (collagen alone) to ~ 2700 Pa (collagen and peptide dimer). Moreover, it was shown that the mechanical properties of a collagen gel can be tailored by using different molar ratios of peptide dimer respect to collagen. The same peptide, functionalized with the triple bond, was used to obtain a peptide-dye conjugate by coupling it with N-(5'-azidopentanoyl)-5-aminofluorescein. An aqueous solution (5 vol\% methanol) of the peptide dye conjugate was injected into a collagen and a hyaluronic acid (HA) gel and images of fluorescence detection showed that the diffusion of the peptide was slower in the collagen gel compared to the HA gel. The third experimental demonstration was gained using the peptide (LSELRLHNN) which showed the lower binding affinity (2.3•10-4 M) to collagen. This peptide was grafted to hyaluronic acid via EDC-chemistry, with a degree of functionalization of 7 ± 2 mol\% as calculated by 1H-NMR. The grafting was further confirmed by FTIR and TGA measurements, which showed that the onset of decomposition for the HA-g-peptide decreased by 10 °C compared to the native HA. Rheological measurements showed that the elastic modulus of a system based on collagen and HA-g-peptide increased by almost two order of magnitude (G' = 200 Pa) compared to a system based on collagen and HA (G' = 0.9 Pa). Overall, this study showed that the synthetic peptides, which were identified from decorin, can be applied as potential building blocks for biomimetic materials that function via biological recognition.}, language = {en} } @article{VillatoroWeberZuehlkeetal.2019, author = {Villatoro, Jos{\´e} Andr{\´e}s and Weber, M. and Z{\"u}hlke, Martin and Lehmann, A. and Zenichowski, Karl and Riebe, Daniel and Beitz, Toralf and L{\"o}hmannsr{\"o}ben, Hans-Gerd and Kreuzer, O.}, title = {Structural characterization of synthetic peptides using electrospray ion mobility spectrometry and molecular dynamics simulations}, series = {International Journal of Mass Spectrometry}, volume = {436}, journal = {International Journal of Mass Spectrometry}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1387-3806}, doi = {10.1016/j.ijms.2018.10.036}, pages = {108 -- 117}, year = {2019}, abstract = {Electrospray ionization-ion mobility spectrometry was employed for the determination of collision cross sections (CCS) of 25 synthetically produced peptides in the mass range between 540-3310 Da. The experimental measurement of the CCS is complemented by their calculation applying two different methods. One prediction method is the intrinsic size parameter (ISP) method developed by the Clemmer group. The second new method is based on the evaluation of molecular dynamics (MD) simulation trajectories as a whole, resulting in a single, averaged collision cross-section value for a given peptide in the gas phase. A high temperature MD simulation is run in order to scan through the whole conformational space. The lower temperature conformational distribution is obtained through thermodynamic reweighting. In the first part, various correlations, e.g. CCS vs. mass and inverse mobility vs. m/z correlations, are presented. Differences in CCS between peptides are also discussed in terms of their respective mass and m/z differences, as well as their respective structures. In the second part, measured and calculated CCS are compared. The agreement between the prediction results and the experimental values is in the same range for both calculation methods. While the calculation effort of the ISP method is much lower, the MD method comprises several tools providing deeper insights into the conformations of peptides. Advantages and limitations of both methods are discussed. Based on the separation of two pairs of linear and cyclic peptides of virtually the same mass, the influence of the structure on the cross sections is discussed. The shift in cross section differences and peak shape after transition from the linear to the cyclic peptide can be well understood by applying different MD tools, e.g. the root-mean-square deviation (RMSD) and the root mean square fluctuation (RMSF). (C) 2018 Elsevier B.V. All rights reserved.}, language = {en} } @article{EggertRawelPawelzik2011, author = {Eggert, Kai and Rawel, Harshadrai Manilal and Pawelzik, Elke}, title = {In vitro degradation of wheat gluten fractions by Fusarium graminearum proteases}, series = {European food research and technology : official organ of the EuCheMS, Division of Food Chemistry}, volume = {233}, journal = {European food research and technology : official organ of the EuCheMS, Division of Food Chemistry}, number = {4}, publisher = {Springer}, address = {New York}, issn = {1438-2377}, doi = {10.1007/s00217-011-1566-x}, pages = {697 -- 705}, year = {2011}, abstract = {Fusarium spp. infection of cereal grain is a common problem, which leads to a dramatic loss of grain quality. The aim of the present study was to investigate the effect of Fusarium infection on the wheat storage protein gluten and its fractions, the gliadins and glutenins, in an in vitro model system. Gluten proteins were digested by F. graminearum proteases for 2, 4, 8 and 24 h, separated by Osborne fractionation and characterised by chromatographic (RP-HPLC) and electrophoretic analysis (SDS-Page). Gluten digestion by F. graminearum proteases showed in comparison with gliadins a preference for the glutenins whereas the HMW subfraction was at most affected. In comparison with a untreated control, the HMW subfraction was degraded of about 97\% after 4 h incubation with Fusarium proteases. Separate digestion of gliadin and glutenin underlined the preference for HMW-GS. Analogue to the observed change in the gluten composition, the yield of the proteins extracted changed. A higher amount of glutenin fragments was found in the gliadin extraction solution after digestion and could mask a gliadin destruction at the same time. This observation can contribute to explain the frequently reported reduced glutenin amount parallel to an increase in gliadin quantity after Fusarium infection in grains.}, language = {en} } @article{KabaMaierSchliebeOhleretal.2015, author = {Kaba, Hani E. J. and Maier, Natalia and Schliebe-Ohler, Nicole and Mayer, Yvonne and Mueller, Peter P. and van den Heuvel, Joop and Schuchhardt, Johannes and Hanack, Katja and Bilitewski, Ursula}, title = {Identification of whole pathogenic cells by monoclonal antibodies generated against a specific peptide from an immunogenic cell wall protein}, series = {Journal of microbiological methods}, volume = {108}, journal = {Journal of microbiological methods}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0167-7012}, doi = {10.1016/j.mimet.2014.11.003}, pages = {61 -- 69}, year = {2015}, abstract = {We selected the immunogenic cell wall beta-(1,3)-glucosyltransferase Bgl2p from Candida albicans as a target protein for the production of antibodies. We identified a unique peptide sequence in the protein and generated monoclonal anti- C. albicans Bgl2p antibodies, which bound in particular to whole C. albicans cells.}, language = {en} } @phdthesis{VillatoroLeal2018, author = {Villatoro Leal, Jos{\´e} Andr{\´e}s}, title = {A combined approach for the analysis of biomolecules using IR-MALDI ion mobility spectrometry and molecular dynamics simulations of peptide ions in the gas phase}, url = {http://nbn-resolving.de/urn:nbn:de:kobv:517-opus4-419723}, school = {Universit{\"a}t Potsdam}, pages = {133}, year = {2018}, abstract = {The aim of this doctoral thesis was to establish a technique for the analysis of biomolecules with infrared matrix-assisted laser dispersion (IR-MALDI) ion mobility (IM) spectrometry. The main components of the work were the characterization of the IR-MALDI process, the development and characterization of different ion mobility spectrometers, the use of IR-MALDI-IM spectrometry as a robust, standalone spectrometer and the development of a collision cross-section estimation approach for peptides based on molecular dynamics and thermodynamic reweighting. First, the IR-MALDI source was studied with atmospheric pressure ion mobility spectrometry and shadowgraphy. It consisted of a metal capillary, at the tip of which a self-renewing droplet of analyte solution was met by an IR laser beam. A relationship between peak shape, ion desolvation, diffusion and extraction pulse delay time (pulse delay) was established. First order desolvation kinetics were observed and related to peak broadening by diffusion, both influenced by the pulse delay. The transport mechanisms in IR-MALDI were then studied by relating different laser impact positions on the droplet surface to the corresponding ion mobility spectra. Two different transport mechanisms were determined: phase explosion due to the laser pulse and electrical transport due to delayed ion extraction. The velocity of the ions stemming from the phase explosion was then measured by ion mobility and shadowgraphy at different time scales and distances from the source capillary, showing an initially very high but rapidly decaying velocity. Finally, the anatomy of the dispersion plume was observed in detail with shadowgraphy and general conclusions over the process were drawn. Understanding the IR-MALDI process enabled the optimization of the different IM spectrometers at atmospheric and reduced pressure (AP and RP, respectively). At reduced pressure, both an AP and an RP IR-MALDI source were used. The influence of the pulsed ion extraction parameters (pulse delay, width and amplitude) on peak shape, resolution and area was systematically studied in both AP and RP IM spectrometers and discussed in the context of the IR-MALDI process. Under RP conditions, the influence of the closing field and of the pressure was also examined for both AP and RP sources. For the AP ionization RP IM spectrometer, the influence of the inlet field (IF) in the source region was also examined. All of these studies led to the determination of the optimal analytical parameters as well as to a better understanding of the initial ion cloud anatomy. The analytical performance of the spectrometer was then studied. Limits of detection (LOD) and linear ranges were determined under static and pulsed ion injection conditions and interpreted in the context of the IR-MALDI mechanism. Applications in the separation of simple mixtures were also illustrated, demonstrating good isomer separation capabilities and the advantages of singly charged peaks. The possibility to couple high performance liquid chromatography (HPLC) to IR-MALDI-IM spectrometry was also demonstrated. Finally, the reduced pressure spectrometer was used to study the effect of high reduced field strength on the mobility of polyatomic ions in polyatomic gases. The last focus point was on the study of peptide ions. A dataset obtained with electrospray IM spectrometry was characterized and used for the calibration of a collision cross-section (CCS) determination method based on molecular dynamics (MD) simulations at high temperature. Instead of producing candidate structures which are evaluated one by one, this semi-automated method uses the simulation as a whole to determine a single average collision cross-section value by reweighting the CCS of a few representative structures. The method was compared to the intrinsic size parameter (ISP) method and to experimental results. Additional MD data obtained from the simulations was also used to further analyze the peptides and understand the experimental results, an advantage with regard to the ISP method. Finally, the CCS of peptide ions analyzed by IR-MALDI were also evaluated with both ISP and MD methods and the results compared to experiment, resulting in a first validation of the MD method. Thus, this thesis brings together the soft ionization technique that is IR-MALDI, which produces mostly singly charged peaks, with ion mobility spectrometry, which can distinguish between isomers, and a collision cross-section determination method which also provides structural information on the analyte at hand.}, language = {en} }