@article{BhuvaneshSaretiaRochetal.2017, author = {Bhuvanesh, Thanga and Saretia, Shivam and Roch, Toralf and Sch{\"o}ne, Anne-Christin and Rottke, Falko O. and Kratz, Karl and Wang, Weiwei and Ma, Nan and Schulz, Burkhard and Lendlein, Andreas}, title = {Langmuir-Schaefer films of fibronectin as designed biointerfaces for culturing stem cells}, series = {Polymers for advanced technologies}, volume = {28}, journal = {Polymers for advanced technologies}, publisher = {Wiley}, address = {Hoboken}, issn = {1042-7147}, doi = {10.1002/pat.3910}, pages = {1305 -- 1311}, year = {2017}, abstract = {Glycoproteins adsorbing on an implant upon contact with body fluids can affect the biological response in vitro and in vivo, depending on the type and conformation of the adsorbed biomacromolecules. However, this process is poorly characterized and so far not controllable. Here, protein monolayers of high molecular cohesion with defined density are transferred onto polymeric substrates by the Langmuir-Schaefer (LS) technique and were compared with solution deposition (SO) method. It is hypothesized that on polydimethylsiloxane (PDMS), a substrate with poor cell adhesion capacity, the fibronectin (FN) layers generated by the LS and SO methods will differ in their organization, subsequently facilitating differential stem cell adhesion behavior. Indeed, atomic force microscopy visualization and immunofluorescence images indicated that organization of the FN layer immobilized on PDMS was uniform and homogeneous. In contrast, FN deposited by SO method was rather heterogeneous with appearance of structures resembling protein aggregates. Human mesenchymal stem cells showed reduced absolute numbers of adherent cells, and the vinculin expression seemed to be higher and more homogenously distributed after seeding on PDMS equipped with FN by LS in comparison with PDMS equipped with FN by SO. These divergent responses could be attributed to differences in the availability of adhesion molecule ligands such as the Arg-Gly-Asp (RGD) peptide sequence presented at the interface. The LS method allows to control the protein layer characteristics, including the thickness and the protein orientation or conformation, which can be harnessed to direct stem cell responses to defined outcomes, including migration and differentiation. Copyright (c) 2016 John Wiley \& Sons, Ltd.}, language = {en} } @article{KoshkinaWestmeierLangetal.2016, author = {Koshkina, Olga and Westmeier, Dana and Lang, Thomas and Bantz, Christoph and Hahlbrock, Angelina and W{\"u}rth, Christian and Resch-Genger, Ute and Braun, Ulrike and Thiermann, Raphael and Weise, Christoph and Eravci, Murat and Mohr, Benjamin and Schlaad, Helmut and Stauber, Roland H. and Docter, Dominic and Bertin, Annabelle and Maskos, Michael}, title = {Tuning the Surface of Nanoparticles: Impact of Poly(2-ethyl-2-oxazoline) on Protein Adsorption in Serum and Cellular Uptake}, series = {Macromolecular bioscience}, volume = {16}, journal = {Macromolecular bioscience}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1616-5187}, doi = {10.1002/mabi.201600074}, pages = {1287 -- 1300}, year = {2016}, abstract = {Due to the adsorption of biomolecules, the control of the biodistribution of nanoparticles is still one of the major challenges of nanomedicine. Poly(2-ethyl-2-oxazoline) (PEtOx) for surface modification of nanoparticles is applied and both protein adsorption and cellular uptake of PEtOxylated nanoparticles versus nanoparticles coated with poly(ethylene glycol) (PEG) and non-coated positively and negatively charged nanoparticles are compared. Therefore, fluorescent poly(organosiloxane) nanoparticles of 15 nm radius are synthesized, which are used as a scaffold for surface modification in a grafting onto approach. With multi-angle dynamic light scattering, asymmetrical flow field-flow fractionation, gel electrophoresis, and liquid chromatography-mass spectrometry, it is demonstrated that protein adsorption on PEtOxylated nanoparticles is extremely low, similar as on PEGylated nanoparticles. Moreover, quantitative microscopy reveals that PEtOxylation significantly reduces the non-specific cellular uptake, particularly by macrophage-like cells. Collectively, studies demonstrate that PEtOx is a very effective alternative to PEG for stealth modification of the surface of nanoparticles.}, language = {en} } @article{NeffevonRuestenLangeBrauneetal.2013, author = {Neffe, Axel T. and von R{\"u}sten-Lange, Maik and Braune, Steffen and L{\"u}tzow, Karola and Roch, Toralf and Richau, Klaus and Jung, Friedrich and Lendlein, Andreas}, title = {Poly(ethylene glycol) grafting to Poly(ether imide) membranes - influence on protein adsorption and Thrombocyte adhesion}, series = {Macromolecular bioscience}, volume = {13}, journal = {Macromolecular bioscience}, number = {12}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1616-5187}, doi = {10.1002/mabi.201300309}, pages = {1720 -- 1729}, year = {2013}, abstract = {The chain length and end groups of linear PEG grafted on smooth surfaces is known to influence protein adsorption and thrombocyte adhesion. Here, it is explored whether established structure function relationships can be transferred to application relevant, rough surfaces. Functionalization of poly(ether imide) (PEI) membranes by grafting with monoamino PEG of different chain lengths (M-n=1kDa or 10kDa) and end groups (methoxy or hydroxyl) is proven by spectroscopy, changes of surface hydrophilicity, and surface shielding effects. The surface functionalization does lead to reduction of adsorption of BSA, but not of fibrinogen. The thrombocyte adhesion is increased compared to untreated PEI surfaces. Conclusively, rough instead of smooth polymer or gold surfaces should be investigated as relevant models.}, language = {en} }