Filtern
Volltext vorhanden
- ja (30) (entfernen)
Erscheinungsjahr
Dokumenttyp
- Postprint (28)
- Teil eines Buches (Kapitel) (2)
Schlagworte
- LIBS (4)
- Diodenlaserspektroskopie (3)
- Fluoreszenz-Resonanz-Energie-Transfer (3)
- Immunoassay (3)
- Kohlendioxid (3)
- Lumineszenz (3)
- Energietransfer (2)
- Isotopenverhältnis (2)
- PCA (2)
- Quantenpunkt (2)
- carbon dioxide (2)
- carbon monoxide (2)
- diode laser spectroscopy (2)
- soil (2)
- 315 nm (1)
- 473 nm (1)
- 946 nm (1)
- Absorption (1)
- Bacteria (1)
- Biophotonik (1)
- Bodengas (1)
- Energy Transfer (1)
- Europium (1)
- FRET (1)
- Fluorescence (1)
- Förster Resonanz Energie Transfer (1)
- Förster-Resonanz-Energie-Transfer (1)
- Genetics (1)
- Ion mobility spectrometry (1)
- Irradiation (1)
- Isotop (1)
- Isotope ratio (1)
- Isotopie (1)
- Kohlenmonoxid (1)
- Lanthanoide (1)
- Laser (1)
- Lichtstreuung (1)
- Luminescence (1)
- NIR spectroscopy (1)
- Nanopartikel (1)
- Neodym-YAG-Laser (1)
- OTDR (1)
- Optode (1)
- PAH (1)
- PLS regression (1)
- PLSR (1)
- Photodynamics (1)
- Prozesskontrolle (1)
- Quantum Dot (1)
- REMPI (1)
- Sauerstoff (1)
- Sensorik (1)
- Serum (1)
- UVR (1)
- [N]phenylene dyads (1)
- [N]phenylenes (1)
- acceptors (1)
- beer (1)
- bioanalysis (1)
- biomass (1)
- biophotonics (1)
- complexes (1)
- continuous-flow (1)
- contrast agents (1)
- copper-bearing minerals (1)
- efficient (1)
- elemental composition (1)
- europium (1)
- fluorescence immunoassay (1)
- fluorescence quenching (1)
- fluoroimmunoassay (1)
- foam analysis (1)
- gaussian processes (1)
- gepulster DPSS Laser (1)
- hydraulic oils (1)
- iPLS regression (1)
- immunoassay (1)
- in-situ (1)
- isotope (1)
- isotope ratios (1)
- labels (1)
- lanthanide luminescence (1)
- laser induced (1)
- laser-induced breakdown spectroscopy (1)
- lasso (1)
- light (1)
- lubricants (1)
- minerals (1)
- molecular oxygen (1)
- nanoparticles (1)
- nutrients (1)
- optical oil sensor (1)
- optical sensing (1)
- optode (1)
- oxygen (1)
- phenanthrenes (1)
- photochemical synthesis (1)
- photoinduced electron transfer (1)
- photon density wave spectroscopy (1)
- precision agriculture (1)
- process analytical technology (1)
- protein-kinase inhibitors (1)
- proximal soil sensing (1)
- pulsed DPSS laser (1)
- quantum dots (1)
- rare earth elements (1)
- resonance energy-transfer (1)
- soil gas (1)
- soil nutrients (1)
- sättigbarer Absorber (1)
- triangular-[4] phenylene (1)
- tunable diode laser (TDL) (1)
Institut
A technique has been developed to measure absolute intracellular oxygen concentrations in green plants. Oxygen-sensitive phosphorescent microbeads were injected into the cells and an optical multifrequency phase-modulation technique was used to discriminate the sensor signal from the strong autofluorescence of the plant tissue. The method was established using photosynthesis-competent cells of the giant algae Chara corallina L., and was validated by application to various cell types of other plant species.
The lack of soil data, which are relevant, reliable, affordable, immediately available, and sufficiently detailed, is still a significant challenge in precision agriculture. A promising technology for the spatial assessment of the distribution of chemical elements within fields, without sample preparation is laser-induced breakdown spectroscopy (LIBS). Its advantages are contrasted by a strong matrix dependence of the LIBS signal which necessitates careful data evaluation. In this work, different calibration approaches for soil LIBS data are presented. The data were obtained from 139 soil samples collected on two neighboring agricultural fields in a quaternary landscape of northeast Germany with very variable soils. Reference analysis was carried out by inductively coupled plasma optical emission spectroscopy after wet digestion. The major nutrients Ca and Mg and the minor nutrient Fe were investigated. Three calibration strategies were compared. The first method was based on univariate calibration by standard addition using just one soil sample and applying the derived calibration model to the LIBS data of both fields. The second univariate model derived the calibration from the reference analytics of all samples from one field. The prediction is validated by LIBS data of the second field. The third method is a multivariate calibration approach based on partial least squares regression (PLSR). The LIBS spectra of the first field are used for training. Validation was carried out by 20-fold cross-validation using the LIBS data of the first field and independently on the second field data. The second univariate method yielded better calibration and prediction results compared to the first method, since matrix effects were better accounted for. PLSR did not strongly improve the prediction in comparison to the second univariate method.
Its properties make copper one of the world’s most important functional metals. Numerous megatrends are increasing the demand for copper. This requires the prospection and exploration of new deposits, as well as the monitoring of copper quality in the various production steps. A promising technique to perform these tasks is Laser Induced Breakdown Spectroscopy (LIBS). Its unique feature, among others, is the ability to measure on site without sample collection and preparation. In this work, copper-bearing minerals from two different deposits are studied. The first set of field samples come from a volcanogenic massive sulfide (VMS) deposit, the second part from a stratiform sedimentary copper (SSC) deposit. Different approaches are used to analyze the data. First, univariate regression (UVR) is used. However, due to the strong influence of matrix effects, this is not suitable for the quantitative analysis of copper grades. Second, the multivariate method of partial least squares regression (PLSR) is used, which is more suitable for quantification. In addition, the effects of the surrounding matrices on the LIBS data are characterized by principal component analysis (PCA), alternative regression methods to PLSR are tested and the PLSR calibration is validated using field samples.
Continuous synthesis of pyridocarbazoles and initial photophysical and bioprobe characterization
(2013)
Pyridocarbazoles when ligated to transition metals yield high affinity kinase inhibitors. While batch photocyclizations enable the synthesis of these heterocycles, the non-oxidative Mallory reaction only provides modest yields and difficult to purify mixtures. We demonstrate here that a flow-based Mallory cyclization provides superior results and enables observation of a clear isobestic point. The flow method allowed us to rapidly synthesize ten pyridocarbazoles and for the first time to document their interesting photophysical attributes. Preliminary characterization reveals that these molecules might be a new class of fluorescent bioprobe.
Hemolysis, the rupturing of red blood cells, can result from numerous medical conditions (in vivo) or occur after collecting blood specimen or extracting plasma and serum out of whole blood (in vitro). In clinical laboratory practice, hemolysis can be a serious problem due to its potential to bias detection of various analytes or biomarkers. Here we present the first ‘‘mix-and-measure’’ method to assess the degree of hemolysis in biosamples using luminescence spectroscopy. Luminescent terbium complexes (LTC) were studied in the presence of free hemoglobin (Hb) as indicators for hemolysis in TRIS-buffer, and in fresh human plasma with absorption, excitation and emission measurements. Our findings indicate dynamic as well as resonance energy transfer (FRET) between the LTC and the porphyrin ligand of hemoglobin. This transfer leads to a decrease in luminescence intensity and decay time even at nanomolar hemoglobin concentrations either in buffer or plasma. Luminescent terbium complexes are very sensitive to free hemoglobin in buffer and blood plasma. Due to the instant change in luminescence properties of the LTC in presence of Hb it is possible to access the concentration of hemoglobin via spectroscopic methods without incubation time or further treatment of the sample thus enabling a rapid and sensitive detection of hemolysis in clinical diagnostics.
The numerous applications of rare earth elements (REE) has lead to a growing global demand and to the search for new REE deposits. One promising technique for exploration of these deposits is laser-induced breakdown spectroscopy (LIBS). Among a number of advantages of the technique is the possibility to perform on-site measurements without sample preparation. Since the exploration of a deposit is based on the analysis of various geological compartments of the surrounding area, REE-bearing rock and soil samples were analyzed in this work. The field samples are from three European REE deposits in Sweden and Norway. The focus is on the REE cerium, lanthanum, neodymium and yttrium. Two different approaches of data analysis were used for the evaluation. The first approach is univariate regression (UVR). While this approach was successful for the analysis of synthetic REE samples, the quantitative analysis of field samples from different sites was influenced by matrix effects. Principal component analysis (PCA) can be used to determine the origin of the samples from the three deposits. The second approach is based on multivariate regression methods, in particular interval PLS (iPLS) regression. In comparison to UVR, this method is better suited for the determination of REE contents in heterogeneous field samples. View Full-Text
Deuteration effects on the vibronic structure of the emission and excitation spectra of triangular [4]phenylene (D3h[4]phenylene) were studied using laser-excited Shpolskii spectroscopy (LESS) in an octane matrix at 4.2 K. For correct assignment of the vibrational modes, the experimental results were compared with calculated frequencies (B3LYP/6-31G*). CH vibrations were identified by their characteristic isotopic shifts in the spectra of deuterated triangular [4]phenylenes. Two CC stretching modes, at 100 cm–1 and 1176 cm–1, suitable as probes for bond strength changes in the excited state, were identified. The isotope effect on the internal conversion rates of triangular [4]phenylene was evaluated from measurements of temperature dependent lifetime. Isotope dependency and the magnitude of the internal conversion rates indicate that internal conversion in triangular [4]phenylene is most likely induced by CH vibrations. The results obtained by LESS and lifetime measurements were compared with PM3 PECI calculations of the excited state structure. The theoretical results and the relation between ground and excited state vibration energies of the 1176 cm–1 probe vibration indicate a reduction of bond alternation of the central cyclohexatriene ring in the excited state.
In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements.
Die Anwendung zweier ähnlicher fasergekoppelte Diodenlaser-Spektrometer-Systeme werden vorgestellt. Basis sind handelsübliche DFB-Laserdioden der optischen Kommunikationstechnik. Der faseroptische Aufbau, das Detektionsverfahren (2f Wellenlängenmodulations-Spektroskopie mit Balanced Receiver), Rauschverhalten und Detektionslimit werden diskutiert. Zur in-situ Plasma-Diagnostik von CO- und CO2-Konzentrationen in industriellen CO2-Lasern der Materialbearbeitung wurde eine Wellenlänge von 1582 nm verwendet. Bei einem Gasdruck von 100 hPa und einer Absorptionsweglänge von 14,9 cm wurden mit einer Laserdiode simultan CO- und CO2-Konzentrationen von 0% bis 11% im Gasgefäß bei laufender Hochfrequenzgasentladung des CO2-Lasers zeitaufgelöst gemessen. Vorgestellt und diskutiert werden Aufbau und Eigenschaften des Spektrometers sowie die Ergebnisse der dynamischen Gasanalysen, die zu einer Verbesserung der Katalysator-Technik im CO2-Laser beigetragen haben.Mit isotopenaufgelöster CO- und CO2-Spektroskopie können biologische Gasaustauschprozesse, z.B. in Gasen aus dem Erdboden untersucht werden. Hierzu wurde ein fasergekoppeltes feldtaugliches Diodenlaser-Spektrometer bei Wellenlängen um 1605 nm zur Messungder Isotopologe 12C16O, 13C16O, 12C18O und 12C16O2, 13C16O2, 12C18O16O aufgebaut. Die Messung erfolgt extraktiv in Langwegzellen mit unterschiedlichen Absorptionsweglängen von 100.9 m und 29.9 m. Es werden Kalibrationsmessungen zur Linearität und zur Präzision der Bestimmung der Isotopenverhältnisse sowie Wiederholungsmessungen zur Stabilität vorgestellt. Nachweisgrenzen von wenigen ppm konnten für die CO- und CO2-Isotopologen erhalten werden.
Improvement of a fluorescence immunoassay with a compact diode-pumped solid state laser at 315 nm
(2006)
We demonstrate the improvement of fluorescence immunoassay (FIA) diagnostics in deploying a newly developed compact diode-pumped solid state (DPSS) laser with emission at 315 nm. The laser is based on the quasi-three-level transition in Nd:YAG at 946 nm. The pulsed operation is either realized by an active Q-switch using an electro-optical device or by introduction of a Cr<SUP>4+</SUP>:YAG saturable absorber as passive Q-switch element. By extra-cavity second harmonic generation in different nonlinear crystal media we obtained blue light at 473 nm. Subsequent mixing of the fundamental and the second harmonic in a β-barium-borate crystal provided pulsed emission at 315 nm with up to 20 μJ maximum pulse energy and 17 ns pulse duration. Substitution of a nitrogen laser in a FIA diagnostics system by the DPSS laser succeeded in considerable improvement of the detection limit. Despite significantly lower pulse energies (7 μJ DPSS laser versus 150 μJ nitrogen laser), in preliminary investigations the limit of detection was reduced by a factor of three for a typical FIA.