The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 4 of 47
Back to Result List

Application of a pnCCD in X-ray diffraction : a three-dimensional X-ray detector

  • The first application of a pnCCD detector for X-ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two-dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse-resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution Delta E/E similar or equal to 10(-2). a three-dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so-called single-photon- counting mode. A full dataset was evaluated taking into account all photons recorded within 10(5) detector frames at a readout rate of 200 Hz. By representing the data in reciprocal-space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a largeThe first application of a pnCCD detector for X-ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two-dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse-resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution Delta E/E similar or equal to 10(-2). a three-dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so-called single-photon- counting mode. A full dataset was evaluated taking into account all photons recorded within 10(5) detector frames at a readout rate of 200 Hz. By representing the data in reciprocal-space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.show moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:Wolfram LeitenbergerGND, Robert Hartmann, Ullrich Pietsch, Robert Andritschke, Ines StarkeORCiD, Lothar Strüder
URL:http://onlinelibrary.wiley.com/iucr/10.1107/S0909049508018931
DOI:https://doi.org/10.1107/S0909049508018931
Publication type:Article
Language:English
Year of first publication:2008
Publication year:2008
Release date:2017/03/25
Source:Journal of synchrotron radiation. - 15 (2008), 5, S. 449 - 457
Organizational units:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Physik und Astronomie
Institution name at the time of the publication:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Physik
Accept ✔
This website uses technically necessary session cookies. By continuing to use the website, you agree to this. You can find our privacy policy here.