• search hit 7 of 10
Back to Result List

Test-retest reliability of the olfactory detection threshold test of the Sniffin' Sticks

  • The aim of the present study was to investigate the test-retest reliability of the olfactory detection threshold subtest of the Sniffin" Sticks test battery, if administered repeatedly on 4 time points. The detection threshold test was repeatedly conducted in 64 healthy subjects. On the first testing session, the threshold test was accomplished 3 times (T(1) = 0 min, T(2) = 35 min, and T(3) = 105 min), representing a short-term testing. A fourth threshold test was conducted on a second testing session (T(4) = 35.1 days after the first testing session), representing a long-term testing. The average scores for olfactory detection threshold for n-butanol did not differ significantly across the 4 points of time. The test-retest reliability (Pearson"s r) between the 4 time points of threshold testing were in a range of 0.43-0.85 (P < 0.01). These results support the notion that the olfactory detection threshold test is a highly reliable method for repeated olfactory testing, even if the test is repeated more than once per day and over aThe aim of the present study was to investigate the test-retest reliability of the olfactory detection threshold subtest of the Sniffin" Sticks test battery, if administered repeatedly on 4 time points. The detection threshold test was repeatedly conducted in 64 healthy subjects. On the first testing session, the threshold test was accomplished 3 times (T(1) = 0 min, T(2) = 35 min, and T(3) = 105 min), representing a short-term testing. A fourth threshold test was conducted on a second testing session (T(4) = 35.1 days after the first testing session), representing a long-term testing. The average scores for olfactory detection threshold for n-butanol did not differ significantly across the 4 points of time. The test-retest reliability (Pearson"s r) between the 4 time points of threshold testing were in a range of 0.43-0.85 (P < 0.01). These results support the notion that the olfactory detection threshold test is a highly reliable method for repeated olfactory testing, even if the test is repeated more than once per day and over a long-term period. It is concluded that the olfactory detection threshold test of the Sniffin" Sticks is suitable for repeated testing during experimental or clinical studies.show moreshow less

Export metadata

Additional Services

Search Google Scholar Statistics
Metadaten
Author details:Jessica Albrecht, Andrea Anzinger, Rainer Kopietz, Veronika Schöpf, Anna Maria Kleemann, Olga Pollatos, Martin Wiesmann
URL:http://chemse.oxfordjournals.org/
ISSN:0379-864X
Publication type:Article
Language:English
Year of first publication:2008
Publication year:2008
Release date:2017/03/25
Source:Chemical senses. - ISSN 0379-864X. - 33 (2008), 5, S. 461 - 467
Organizational units:Humanwissenschaftliche Fakultät / Strukturbereich Kognitionswissenschaften / Department Psychologie
Peer review:Referiert
Accept ✔
This website uses technically necessary session cookies. By continuing to use the website, you agree to this. You can find our privacy policy here.