Validation of a new point-of-care assay for determination of ss-carotene concentration in bovine whole blood and plasma
- Background: beta-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. beta-Carotene concentrations in plasma are used to optimize beta-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure beta-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). Objective: The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring beta-carotene in whole blood and plasma. Methods: beta-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Results: Concentrations of beta-carotene in plasma measured using the POC assayBackground: beta-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. beta-Carotene concentrations in plasma are used to optimize beta-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure beta-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). Objective: The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring beta-carotene in whole blood and plasma. Methods: beta-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Results: Concentrations of beta-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean +/- SD; n = 166): HPLC-plasma 4.23 +/- 2.35 mg/L; POC-plasma 4.49 +/- 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 +/- 2.12 mg/L; POC-whole blood 3.67 +/- 2.29 mg/L. Conclusions: Concentrations of beta-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding beta-carotene deficiency facilitates rapid and appropriate optimization of beta-carotene supplementation in feed.…
Author details: | Jens RailaORCiDGND, Francis Enjalbert, Ralf Mothes, Andrea Hurtienne, Florian J. SchweigertORCiDGND |
---|---|
DOI: | https://doi.org/10.1111/j.1939-165X.2012.00400.x |
ISSN: | 0275-6382 |
Title of parent work (English): | Veterinary clinical pathology |
Publisher: | Wiley-Blackwell |
Place of publishing: | Malden |
Publication type: | Article |
Language: | English |
Year of first publication: | 2012 |
Publication year: | 2012 |
Release date: | 2017/03/26 |
Tag: | Biomarker; HPLC; method comparison; nutritional supplements; vitamin A |
Volume: | 41 |
Issue: | 1 |
Number of pages: | 4 |
First page: | 119 |
Last Page: | 122 |
Organizational units: | Mathematisch-Naturwissenschaftliche Fakultät / Institut für Ernährungswissenschaft |
Peer review: | Referiert |