The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 81 of 263
Back to Result List

Entwicklung einer parallelen Mehrkomponentenanalyse von Antigen-Antikörper-Reaktionen in der Dopinganalyse

Development of a multiplex-assay for the analysis of antigen-antibody reactions in doping analysis

  • Weltweit streben Anti-Doping Institute danach jene Sportler zu überführen, welche sich unerlaubter Mittel oder Methoden bedienen. Die hierfür notwendigen Testsysteme werden kontinuierlich weiterentwickelt und neue Methoden aufgrund neuer Wirkstoffe der Pharmaindustrie etabliert. Gegenstand dieser Arbeit war es, eine parallele Mehrkomponentenanalyse auf Basis von Antigen-Antikörper Reaktionen zu entwickeln, bei dem es primär um Verringerung des benötigten Probevolumens und der Versuchszeit im Vergleich zu einem Standard Nachweis-Verfahren ging. Neben der Verwendung eines Multiplex Ansatzes und der Mikroarraytechnologie stellten ebenfalls die Genauigkeit aller Messparameter, die Stabilität des Versuchsaufbaus sowie die Performance über einen Einfach-Blind-Ansatz Herausforderungen dar. Die Anforderung an den Multiplex Ansatz, keine falschen Signale trotz ähnlicher Strukturen zu messen, konnte durch die gezielte Kombination von spezifischen Antikörpern realisiert werden. Hierfür wurden neben Kreuzreaktivitätstests auf dem MikroarrayWeltweit streben Anti-Doping Institute danach jene Sportler zu überführen, welche sich unerlaubter Mittel oder Methoden bedienen. Die hierfür notwendigen Testsysteme werden kontinuierlich weiterentwickelt und neue Methoden aufgrund neuer Wirkstoffe der Pharmaindustrie etabliert. Gegenstand dieser Arbeit war es, eine parallele Mehrkomponentenanalyse auf Basis von Antigen-Antikörper Reaktionen zu entwickeln, bei dem es primär um Verringerung des benötigten Probevolumens und der Versuchszeit im Vergleich zu einem Standard Nachweis-Verfahren ging. Neben der Verwendung eines Multiplex Ansatzes und der Mikroarraytechnologie stellten ebenfalls die Genauigkeit aller Messparameter, die Stabilität des Versuchsaufbaus sowie die Performance über einen Einfach-Blind-Ansatz Herausforderungen dar. Die Anforderung an den Multiplex Ansatz, keine falschen Signale trotz ähnlicher Strukturen zu messen, konnte durch die gezielte Kombination von spezifischen Antikörpern realisiert werden. Hierfür wurden neben Kreuzreaktivitätstests auf dem Mikroarray parallel erfolgreich Western Blot Versuche durchgeführt. Jene Antikörper, welche in diesen Versuchen die gesetzten Anforderungen erfüllten, wurden für das Ermitteln der kleinsten nachweisbaren Konzentration verwendet. Über das Optimieren der Versuchsbedingungen konnte unter Verwendung von Tween in der Waschlösung sowohl auf Glas als auch auf Kunststoff die Hintergrundfluoreszenz reduziert und somit eine Steigerung des Signal/Hintergrundverhältnisses erreicht werden. In den Versuchen zu Ermittlung der Bestimmungsgrenze wurde für das humane Choriongonadotropin (hCG-i) eine Konzentration von 10 mU/ml, für dessen beta-Untereinheit (hCG-beta) eine Konzentration von 3,6 mU/ml und für das luteinisierende Hormon (LH) eine Konzentration von 10 mU/ml bestimmt. Den ermittelten Wert im Serum für das hCG-i entspricht dem von der Welt-Anti-Dopin-Agentur (WADA) geforderten Wert in Urin von 5 mU/ml. Neben der Ermittlung von Bestimmungsgrenzen wurden diese hinsichtlich auftretender Matrixeffekte in Serum und Blut gemessen. Wie aus den Versuchen zur Ermittlung von Kreuzreaktivitäten auf dem Mikroarray zu entnehmen ist, lassen sich das LH, das hCG-i und hCG-β ebenfalls in Serum und Blut messen. Die Durchführung einer Performance-Analyse über einem Einfach-Blind-Ansatz mit 130 Serum Proben, wurde ebenfalls über dieses System realisiert. Die ausgewerteten Proben wurden anschließend über eine Grenzwertoptimierungskurve analysiert und die diagnostische Spezifität ermittelt. Für die Messungen des LH konnte eine Sensitivität und Spezifität von 100% erreicht werden. Demnach wurden alle negativen und positiven Proben eindeutig interpretiert. Für das hCG-β konnte ebenfalls eine Spezifität von 100% und eine Sensitivität von 97% erreicht werden. Die hCG-i Proben wurden mit einer Spezifität von 100% und eine Sensitivität von 97,5% gemessen. Um den Nachweis zu erbringen, dass dieser Versuchsaufbau über mehrere Wochen stabile Signale bei Vermessen von identischen Proben liefert, wurde ein über zwölf Wochen angesetzter Stabilitätstest für alle Parameter erfolgreich in Serum und Blut durchgeführt. Zusammenfassend konnte in dieser Arbeit erfolgreich eine Mehrkomponentenanalyse als Multiplex Ansatz auf einem Mikroarray entwickelt werden. Die Durchführung der Performance-Analyse und des Stabilitätstests zeigen bereits die mögliche Einsatzfähigkeit dieses Tests im Kontext einer Dopinganalyse.show moreshow less
  • Worldwide it is the goal of anti-doping institutes to have a fair competition in sports free of doping and to prevent the misuse of therapeutics for doping purposes. Therefore there is a need to continuously develop new rapid test methods for the analysis and identification of pharmaceutical substances. Herein, the focus was to develop a multiplex assay on the basis of antigen antibody reactions in doping analysis. It was one goal to reduce the sample volume and the measurement time in comparison to standard methods (i.e. ELISA). Additional challenges were the application of a multiplex approach on the basis of microarray technology and to achieve a high sensitivity and precision. The major challenge for a multiplex analysis is the specific detection of all analytes without producing false positive signals, even of those analytes with similar molecular structure. This was solved using a special combination of specific monoclonal antibodies. Therefore cross-reaction-tests on the microarray platform and western blot analysis wereWorldwide it is the goal of anti-doping institutes to have a fair competition in sports free of doping and to prevent the misuse of therapeutics for doping purposes. Therefore there is a need to continuously develop new rapid test methods for the analysis and identification of pharmaceutical substances. Herein, the focus was to develop a multiplex assay on the basis of antigen antibody reactions in doping analysis. It was one goal to reduce the sample volume and the measurement time in comparison to standard methods (i.e. ELISA). Additional challenges were the application of a multiplex approach on the basis of microarray technology and to achieve a high sensitivity and precision. The major challenge for a multiplex analysis is the specific detection of all analytes without producing false positive signals, even of those analytes with similar molecular structure. This was solved using a special combination of specific monoclonal antibodies. Therefore cross-reaction-tests on the microarray platform and western blot analysis were performed simultaneously. Subsequently, the relevant antibodies were used for the analysis of the minimum detectable concentration. Optimization of experimental conditions on glass and polymer surfaces (i.e. COP) led to a reduction of the background fluorescence, resulting in an increase of signal-to-background ratio. The measured limit of detection (LOD) for the human choriongonadotropin (hCG-i) was a concentration of 10 mU/ml, for the beta-subunit (hCG-beta) 3,6 mU/ml and for the luteinizing hormone (LH) 10 mU/ml. The value of hCG-i in serum correlates to the claimed threshold limit from the world anti doping agency (WADA) of 5 mU/ml in urine. In parallel, matrix effects were analyzed in serum and whole blood. In a crossreactivity study it was shown, that it is possible to measure all three parameters in serum and whole blood independently. The performance analysis of a blinded experiment with 130 serum samples was analyzed with receiver operating characteristic (ROC) and showed the diagnostic specificity. For LH the specificity and sensitivity was 100%, for hCG-beta a specificity of 100% and a sensitivity of 97% was measured. The samples for hCG-i were measured with a specificity of 100% and a sensitivity of 97,5%. For the evidence of stability for several weeks of the experimental setup, a stability testing over a period of 12 weeks was performed. Identical samples gave stable signals over a period of 10 weeks in serum as well as in whole blood. In summary the development of a multiplex assay for the analysis of antigen-antibody reactions in doping analysis for LH and hCG was successful and represents a proof of concept. Due to the promising results in the performance analysis and the stability tests it might be possible to insert that kind of multiplex assay as a test method for the anti doping analysis.show moreshow less

Download full text files

Export metadata

Metadaten
Author details:Kai Wunderlich
URN:urn:nbn:de:kobv:517-opus4-76869
Supervisor(s):Frank Fabian Bier
Publication type:Doctoral Thesis
Language:German
Publication year:2014
Publishing institution:Universität Potsdam
Granting institution:Universität Potsdam
Date of final exam:2015/04/24
Release date:2015/06/25
Tag:Doping; Mehrkomponentenanalyse; Multiplex; Schnelltest; hCG
dopingtest; in-vitro diagnostic; microarray; multiplex assay; point-of-care
Number of pages:VIII, 130
RVK - Regensburg classification:XI 4504, ZX 9420, XI 2104
Organizational units:Mathematisch-Naturwissenschaftliche Fakultät / Institut für Biochemie und Biologie
DDC classification:5 Naturwissenschaften und Mathematik / 57 Biowissenschaften; Biologie / 570 Biowissenschaften; Biologie
License (German):License LogoCC-BY-NC-ND - Namensnennung, nicht kommerziell, keine Bearbeitungen 4.0 International
Accept ✔
This website uses technically necessary session cookies. By continuing to use the website, you agree to this. You can find our privacy policy here.