The first electrochemical MIP sensor for tamoxifen
- We present an electrochemical MIP sensor for tamoxifen (TAM)-a nonsteroidal anti-estrogen-which is based on the electropolymerisation of an O-phenylenediamine. resorcinol mixture directly on the electrode surface in the presence of the template molecule. Up to now only. bulk. MIPs for TAM have been described in literature, which are applied for separation in chromatography columns. Electro-polymerisation of the monomers in the presence of TAM generated a film which completely suppressed the reduction of ferricyanide. Removal of the template gave a markedly increased ferricyanide signal, which was again suppressed after rebinding as expected for filling of the cavities by target binding. The decrease of the ferricyanide peak of the MIP electrode depended linearly on the TAM concentration between 1 and 100 nM. The TAM-imprinted electrode showed a 2.3 times higher recognition of the template molecule itself as compared to its metabolite 4-hydroxytamoxifen and no cross-reactivity with the anticancer drug doxorubucin was found.We present an electrochemical MIP sensor for tamoxifen (TAM)-a nonsteroidal anti-estrogen-which is based on the electropolymerisation of an O-phenylenediamine. resorcinol mixture directly on the electrode surface in the presence of the template molecule. Up to now only. bulk. MIPs for TAM have been described in literature, which are applied for separation in chromatography columns. Electro-polymerisation of the monomers in the presence of TAM generated a film which completely suppressed the reduction of ferricyanide. Removal of the template gave a markedly increased ferricyanide signal, which was again suppressed after rebinding as expected for filling of the cavities by target binding. The decrease of the ferricyanide peak of the MIP electrode depended linearly on the TAM concentration between 1 and 100 nM. The TAM-imprinted electrode showed a 2.3 times higher recognition of the template molecule itself as compared to its metabolite 4-hydroxytamoxifen and no cross-reactivity with the anticancer drug doxorubucin was found. Measurements at + 1.1 V caused a fouling of the electrode surface, whilst pretreatment of TAM with peroxide in presence of HRP generated an oxidation product which was reducible at 0 mV, thus circumventing the polymer formation and electrochemical interferences.…
Author details: | Aysu YarmanORCiDGND, Frieder W. SchellerORCiDGND |
---|---|
URN: | urn:nbn:de:kobv:517-opus4-476173 |
DOI: | https://doi.org/10.25932/publishup-47617 |
ISSN: | 1866-8372 |
Title of parent work (German): | Postprints der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe |
Publication series (Volume number): | Zweitveröffentlichungen der Universität Potsdam : Mathematisch-Naturwissenschaftliche Reihe (1046) |
Publication type: | Postprint |
Language: | English |
Date of first publication: | 2020/12/18 |
Publication year: | 2014 |
Publishing institution: | Universität Potsdam |
Release date: | 2020/12/18 |
Tag: | anticancer drug; electropolymerisation; molecularly imprinted polymers; tamoxifen |
Issue: | 1046 |
Number of pages: | 10 |
Source: | Sensors 14(2014) 5, 7647-7654; DOI: 10.3390/s140507647 |
Funding institution: | Deutsche Forschungsgemeinschaft (DFG) within the framework of the German Excellence Initiative [EXC 314] |
Organizational units: | Mathematisch-Naturwissenschaftliche Fakultät / Institut für Biochemie und Biologie |
DDC classification: | 6 Technik, Medizin, angewandte Wissenschaften / 62 Ingenieurwissenschaften / 620 Ingenieurwissenschaften und zugeordnete Tätigkeiten |
Peer review: | Referiert |
Publishing method: | Open Access / Green Open-Access |
License (German): | CC-BY - Namensnennung 4.0 International |
External remark: | Bibliographieeintrag der Originalveröffentlichung/Quelle |